The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
An integrated microfluidic system for long-term perfusion culture and on-line monitoring of intestinal tissue models
Abstract
Conventional cell-based assays in life science and medical applications can be difficult to maintain functionally over long periods. Microfluidics is an emerging technology with potential to provide integrated environments for cell maintenance, continuous perfusion, and monitoring. In this study, we developed an integrated microfluidic device with on-chip pumping and detection functionalities. The microfluidic structure in the device is divided into two independent channels separated by a semipermeable membrane on which cells are inoculated and cultured. Perfusion and fluorescence measurements of culture media for each channel can be conducted by the on-chip pumping system and optical fiber detection system. Performance of the device was examined through long-term culture and monitoring of polarized transport activity of intestinal tissue models (Caco-2 cells). The cells could be cultured for more than two weeks, and monolayer transport of rhodamine 123 was successfully monitored by on-line fluorescent measurement. This device may have applications in toxicity testing and drug screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Hidalgo, I. J., Raub, T. J., & Borchardt, R. T. (1989) · Gastroenterology · doi:10.1016/s0016-5085(89)80072-1 · Cited by 2,396
Artursson, P., & Karlsson, J. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91647-u · Cited by 1,893
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
Effects of nonionic surfactants on membrane transporters in Caco-2 cell monolayers
Rege, B. D., Kao, J. P. Y., & Polli, J. E. (2002) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(02)00055-6 · Cited by 509
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
The human intestinal epithelial cell line Caco-2; pharmacological and pharmacokinetic applications
Meunier, V., Bourri�, M., Berger, Y., & Fabre, G. (1995) · Cell Biology and Toxicology · doi:10.1007/bf00756522 · Cited by 434
Microenvironment design considerations for cellular scale studies
Walker, G. M., Zeringue, H. C., & Beebe, D. J. (2004) · Lab on a Chip · doi:10.1039/b311214d · Cited by 388
Sin, A., Chin, K. C., Jamil, M. F., Kostov, Y., Rao, G., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp034077d · Cited by 368
Differentiation-on-a-chip: A microfluidic platform for long-term cell culture studies
Tourovskaia, A., Figueroa-Masot, X., & Folch, A. (2005) · Lab on a Chip · doi:10.1039/b405719h · Cited by 363
Microfabrication Technology for Vascularized Tissue Engineering
Borenstein, J. T., Terai, H., King, K. R., Weinberg, E. J., Kaazempur-Mofrad, M. R., & Vacanti, J. P. (2002) · Biomedical Microdevices · doi:10.1023/a:1016040212127 · Cited by 361
Development of a Microscale Cell Culture Analog To Probe Naphthalene Toxicity
Viravaidya, K., Sin, A., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp0341996 · Cited by 305
Computer-Controlled Microcirculatory Support System for Endothelial Cell Culture and Shearing
Song, J. W., Gu, W., Futai, N., Warner, K. A., Nor, J. E., & Takayama, S. (2005) · Analytical Chemistry · doi:10.1021/ac050131o · Cited by 249
Microfluidic PDMS (Polydimethylsiloxane) Bioreactor for Large-Scale Culture of Hepatocytes
Leclerc, E., Sakai, Y., & Fujii, T. (2004) · Biotechnology Progress · doi:10.1021/bp0300568 · Cited by 234
Self-citationYumoto, R., Murakami, T., Nakamoto, Y., Hasegawa, R., Nagai, J., & Takano, M. (1999) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)38117-0 · Cited by 184
Viravaidya, K., & Shuler, M. L. (2004) · Biotechnology Progress · doi:10.1021/bp034238d · Cited by 184
Troutman, M. D., & Thakker, D. R. (2003) · Pharmaceutical Research · doi:10.1023/a:1025096930604 · Cited by 134
van der Sandt, I. C. J., Blom-Roosemalen, M. C. M., de Boer, A. G., & Breimer, D. D. (2000) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(00)00097-x · Cited by 110
Ges, I. A., Ivanov, B. L., Werdich, A. A., & Baudenbacher, F. J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.033 · Cited by 64
Transepithelial Taurine Transport in Caco-2 Cell Monolayers
Roig-Pérez, S., Moretó, M., & Ferrer, R. (2005) · The Journal of Membrane Biology · doi:10.1007/s00232-005-0750-y · Cited by 35
Microfluidic Perfusion Culture of Human Hepatocytes
Kimura, H., Nishikawa, M., Yamamoto, T., Sakai, Y., & Fujii, T. (2007) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2007.p0550 · Cited by 3
Self-citation
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Metadata
- Authors
- Kimura, H., Yamamoto, T., Sakai, H., Sakai, Y., & Fujii, T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 5
- Pages
- 741
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2164358915
- Cited by
- 290
- References
- 26
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.