The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
An integrated microfluidic system for long-term perfusion culture and on-line monitoring of intestinal tissue models
Abstract
Conventional cell-based assays in life science and medical applications can be difficult to maintain functionally over long periods. Microfluidics is an emerging technology with potential to provide integrated environments for cell maintenance, continuous perfusion, and monitoring. In this study, we developed an integrated microfluidic device with on-chip pumping and detection functionalities. The microfluidic structure in the device is divided into two independent channels separated by a semipermeable membrane on which cells are inoculated and cultured. Perfusion and fluorescence measurements of culture media for each channel can be conducted by the on-chip pumping system and optical fiber detection system. Performance of the device was examined through long-term culture and monitoring of polarized transport activity of intestinal tissue models (Caco-2 cells). The cells could be cultured for more than two weeks, and monolayer transport of rhodamine 123 was successfully monitored by on-line fluorescent measurement. This device may have applications in toxicity testing and drug screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Hidalgo, I. J., Raub, T. J., & Borchardt, R. T. (1989) · Gastroenterology · doi:10.1016/s0016-5085(89)80072-1 · Cited by 2,396
Artursson, P., & Karlsson, J. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91647-u · Cited by 1,893
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
Effects of nonionic surfactants on membrane transporters in Caco-2 cell monolayers
Rege, B. D., Kao, J. P. Y., & Polli, J. E. (2002) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(02)00055-6 · Cited by 509
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Development of a primary human Small Intestine-on-a-Chip using biopsy-derived organoids
Kasendra, M., Tovaglieri, A., Sontheimer-Phelps, A., Jalili-Firoozinezhad, S., Bein, A., Chalkiadaki, A., Scholl, W., Zhang, C., Rickner, H., Richmond, C. A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21201-7 · Cited by 754
Microfabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Hoarau-Véchot, J., Rafii, A., Touboul, C., & Pasquier, J. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19010181 · Cited by 489
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435
Self-citationMicrofluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Wang, Y., Gunasekara, D. B., Reed, M. I., DiSalvo, M., Bultman, S. J., Sims, C. E., Magness, S. T., & Allbritton, N. L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.005 · Cited by 373
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
Advances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Micro and nanoscale technologies in oral drug delivery
Ahadian, S., Finbloom, J. A., Mofidfar, M., Diltemiz, S. E., Nasrollahi, F., Davoodi, E., Hosseini, V., Mylonaki, I., Sangabathuni, S., Montazerian, H., et al. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.012 · Cited by 268
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Delon, L. C., Guo, Z., Oszmiana, A., Chien, C.-C., Gibson, R., Prestidge, C., & Thierry, B. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119521 · Cited by 171
A microfluidic system to evaluate intestinal absorption
Imura, Y., Asano, Y., Sato, K., & Yoshimura, E. (2009) · Analytical Sciences · doi:10.2116/analsci.25.1403 · Cited by 159
A multi-chamber microfluidic intestinal barrier model using Caco-2 cells for drug transport studies
Tan, H.-Y., Trier, S., Rahbek, U. L., Dufva, M., Kutter, J. P., & Andresen, T. L. (2018) · PLOS ONE · doi:10.1371/journal.pone.0197101 · Cited by 143
An On-Chip Small Intestine–Liver Model for Pharmacokinetic Studies
Kimura, H., Ikeda, T., Nakayama, H., Sakai, Y., & Fujii, T. (2015) · SLAS Technology · doi:10.1177/2211068214557812 · Cited by 136
Self-citationCancer-on-a-chip systems at the frontier of nanomedicine
Zhang, Y. S., Zhang, Y.-N., & Zhang, W. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.03.011 · Cited by 127
Schneeberger, K., Spee, B., Costa, P., Sachs, N., Clevers, H., & Malda, J. (2017) · Biofabrication · doi:10.1088/1758-5090/aa6121 · Cited by 100
Fois, C. A. M., Schindeler, A., Valtchev, P., & Dehghani, F. (2021) · Biomedical Microdevices · doi:10.1007/s10544-021-00591-y · Cited by 82
Rumsey, J. W., Lorance, C., Jackson, M., Sasserath, T., McAleer, C. W., Long, C. J., Goswami, A., Russo, M. A., Raja, S. M., Gable, K. L., et al. (2022) · Advanced Therapeutics · doi:10.1002/adtp.202200030 · Cited by 74
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Farewell to Animal Testing: Innovations on Human Intestinal Microphysiological Systems
Kang, T., & Kim, H. (2016) · Micromachines · doi:10.3390/mi7070107 · Cited by 40
Shinha, K., Nihei, W., Nakamura, H., Goto, T., Kawanishi, T., Ishida, N., Yamazaki, N., Imakura, Y., Mima, S., Inamura, K., et al. (2021) · Micromachines · doi:10.3390/mi12091007 · Cited by 36
Self-citationHuman stroma and epithelium co-culture in a microfluidic model of a human prostate gland
Jiang, L., Ivich, F., Tahsin, S., Tran, M., Frank, S. B., Miranti, C. K., & Zohar, Y. (2019) · Biomicrofluidics · doi:10.1063/1.5126714 · Cited by 31
Kimura, H., Nakamura, H., Goto, T., Uchida, W., Uozumi, T., Nishizawa, D., Shinha, K., Sakagami, J., & Doi, K. (2024) · Lab on a Chip · doi:10.1039/d3lc00934c · Cited by 20
Self-citationKutsuzawa, N., Nakamura, H., Shinha, K., & Kimura, H. (2026) · Frontiers in Toxicology · doi:10.3389/ftox.2026.1854389
Self-citation
Metadata
- Authors
- Kimura, H., Yamamoto, T., Sakai, H., Sakai, Y., & Fujii, T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 5
- Pages
- 741
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2164358915
- Cited by
- 290
- References
- 26
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.