The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Continuous separation of cells and particles in microfluidic systems
Abstract
The progress in microfabrication and lab-on-a-chip technologies has been a major area of development for new approaches to bioanalytics and integrated concepts for cell biology. Fundamental advances in the development of elastomer based microfluidics have been driving factors for making microfluidic technology available to a larger scientific community in the past years. In line with this, microfluidic separation of cells and particles is currently developing rapidly where key areas of interest are found in designing lab-on-a-chip systems that offer controlled microenvironments for studies of fundamental cell biology. More recently industrial interests are seen in the development of micro chip based flow cytometry technology both for preclinical research and clinical diagnostics. This critical review outlines the most recent developments in microfluidic technology for cell and particle separation in continuous flow based systems. (130 references).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Acceleration and Trapping of Particles by Radiation Pressure
Ashkin, A. (1970) · Physical Review Letters · doi:10.1103/physrevlett.24.156 · Cited by 5,013
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
A rapid method for the isolation of functional thymus‐derived murine lymphocytes
Julius, M. H., Simpson, E., & Herzenberg, L. A. (1973) · European Journal of Immunology · doi:10.1002/eji.1830031011 · Cited by 4,147
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Optical Trapping and Manipulation of Viruses and Bacteria
Ashkin, A., & Dziedzic, J. M. (1987) · Science · doi:10.1126/science.3547653 · Cited by 2,191
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
On-chip manipulation of single microparticles, cells, and organisms using surface acoustic waves
Ding, X., Lin, S.-C. S., Kiraly, B., Yue, H., Li, S., Chiang, I.-K., Shi, J., Benkovic, S. J., & Huang, T. J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209288109 · Cited by 912
Acoustic separation of circulating tumor cells
Li, P., Mao, Z., Peng, Z., Zhou, L., Chen, Y., Huang, P.-H., Truica, C. I., Drabick, J. J., El-Deiry, W. S., Dao, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1504484112 · Cited by 782
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Inertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Acoustic Purification of Extracellular Microvesicles
Lee, K., Shao, H., Weissleder, R., & Lee, H. (2015) · ACS Nano · doi:10.1021/nn506538f · Cited by 534
Cell separation using tilted-angle standing surface acoustic waves
Ding, X., Peng, Z., Lin, S.-C. S., Geri, M., Li, S., Li, P., Chen, Y., Dao, M., Suresh, S., & Huang, T. J. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1413325111 · Cited by 490
Hydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
Acoustofluidics 8: Applications of acoustophoresis in continuous flow microsystems
Lenshof, A., Magnusson, C., & Laurell, T. (2012) · Lab on a Chip · doi:10.1039/c2lc21256k · Cited by 353
Self-citationLab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Yang, S., Kim, J. Y., Lee, S. J., Lee, S. S., & Kim, J. M. (2011) · Lab Chip · doi:10.1039/c0lc00102c · Cited by 306
Biocatalytic Feedback‐Driven Temporal Programming of Self‐Regulating Peptide Hydrogels
Heuser, T., Weyandt, E., & Walther, A. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201505013 · Cited by 266
Dielectrophoretic separation of bioparticles in microdevices: A review
Jubery, T. Z., Srivastava, S. K., & Dutta, P. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201300424 · Cited by 262
Advancements in microfluidics for nanoparticle separation
Salafi, T., Zeming, K. K., & Zhang, Y. (2017) · Lab on a Chip · doi:10.1039/c6lc01045h · Cited by 261
Synthetic Ligand-Coated Magnetic Nanoparticles for Microfluidic Bacterial Separation from Blood
Lee, J.-J., Jeong, K. J., Hashimoto, M., Kwon, A. H., Rwei, A., Shankarappa, S. A., Tsui, J. H., & Kohane, D. S. (2014) · Nano Letters · doi:10.1021/nl3047305 · Cited by 258
Acoustofluidics 5: Building microfluidic acoustic resonators
Lenshof, A., Evander, M., Laurell, T., & Nilsson, J. (2012) · Lab on a Chip · doi:10.1039/c1lc20996e · Cited by 252
Self-citationImaging FlowCytobot modified for high throughput by in-line acoustic focusing of sample particles
Olson, R. J., Shalapyonok, A., Kalb, D. J., Graves, S. W., & Sosik, H. M. (2017) · Limnology and Oceanography: Methods · doi:10.1002/lom3.10205 · Cited by 36
Metadata
- Authors
- Lenshof, A., & Laurell, T.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 3
- Pages
- 1203
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2132011262
- Cited by
- 528
- References
- 85
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.