The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Lab-on-a-Foil: microfluidics on thin and flexible films
Abstract
This critical review is motivated by an increasing interest of the microfluidics community in developing complete Lab-on-a-Chip solutions based on thin and flexible films (Lab-on-a-Foil). Those implementations benefit from a broad range of fabrication methods that are partly adopted from well-established macroscale processes or are completely new and promising. In addition, thin and flexible foils enable various features like low thermal resistance for efficient thermocycling or integration of easily deformable chambers paving the way for new means of on-chip reagent storage or fluid transport. From an economical perspective, Lab-on-a-Foil systems are characterised by low material consumption and often low-cost materials which are attractive for cost-effective high-volume fabrication of self-contained disposable chips. The first part of this review focuses on available materials, fabrication processes and approaches for integration of microfluidic functions including liquid control and transport as well as storage and release of reagents. In the second part, an analysis of the state of Lab-on-a-Foil applications is provided with a special focus on nucleic acid analysis, immunoassays, cell-based assays and home care testing. We conclude that the Lab-on-a-Foil approach is very versatile and significantly expands the toolbox for the development of Lab-on-a-Chip solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Food Packaging—Roles, Materials, and Environmental Issues
Marsh, K., & Bugusu, B. (2007) · Journal of Food Science · doi:10.1111/j.1750-3841.2007.00301.x · Cited by 1,919
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Self-citationUnderstanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Self-citationReview on micro molding of thermoplastic polymers
Heckele, M., & Schomburg, W. K. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/3/r01 · Cited by 915
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
Bonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
Biocompatibility and biofouling of MEMS drug delivery devices
Voskerician, G., Shive, M. S., Shawgo, R. S., Recum, H. V., Anderson, J. M., Cima, M. J., & Langer, R. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00565-3 · Cited by 558
Scientific Status Summary: Innovative Food Packaging Solutions
Brody, A. L., Bugusu, B., Han, J. H., Sand, C. K., & McHugh, T. H. (2008) · Journal of Food Science · doi:10.1111/j.1750-3841.2008.00933.x · Cited by 533
UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems
Roberts, M. A., Rossier, J. S., Bercier, P., & Girault, H. (1997) · Analytical Chemistry · doi:10.1021/ac961038q · Cited by 497
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Membranes and microfluidics: a review
de Jong, J., Lammertink, R. G. H., & Wessling, M. (2006) · Lab on a Chip · doi:10.1039/b603275c · Cited by 483
Micro-injection moulding of polymer microfluidic devices
Attia, U. M., Marson, S., & Alcock, J. R. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0421-x · Cited by 474
Fabrication of Poly(ethylene glycol) Hydrogel Microstructures Using Photolithography
Revzin, A., Russell, R. J., Yadavalli, V. K., Koh, W.-G., Deister, C., Hile, D. D., Mellott, M. B., & Pishko, M. V. (2001) · Langmuir · doi:10.1021/la010075w · Cited by 472
Developments and new applications of UV-induced surface graft polymerizations
DENG, J., WANG, L., LIU, L., & YANG, W. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.06.002 · Cited by 465
Zhang, C., & Xing, D. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm389 · Cited by 417
The centrifugal microfluidic Bio-Disk platform
Ducrée, J., Haeberle, S., Lutz, S., Pausch, S., Stetten, F. V., & Zengerle, R. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/s07 · Cited by 405
Self-citationXurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Lutz, S., Weber, P., Focke, M., Faltin, B., Hoffmann, J., Müller, C., Mark, D., Roth, G., Munday, P., Armes, N., et al. (2010) · Lab on a Chip · doi:10.1039/b921140c · Cited by 344
Self-citationOptical properties of cyclic olefin copolymers
Khanarian, G. (2001) · Optical Engineering · doi:10.1117/1.1369411 · Cited by 295
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J. (2008) · Lab on a Chip · doi:10.1039/b811314a · Cited by 259
Shrinky-Dink microfluidics: rapid generation of deep and rounded patterns
Grimes, A., Breslauer, D. N., Long, M., Pegan, J., Lee, L. P., & Khine, M. (2008) · Lab Chip · doi:10.1039/b711622e · Cited by 211
Principles and Technical Aspects of PCR Amplification
van Pelt-Verkuil, E., van Belkum, A., & Hays, J. P. (2008) · Springer eBooks · doi:10.1007/978-1-4020-6241-4 · Cited by 197
Schubert-Ullrich, P., Rudolf, J., Ansari, P., Galler, B., Führer, M., Molinelli, A., & Baumgartner, S. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2715-y · Cited by 197
Rapid prototyping of microfluidic chips in COC
Steigert, J., Haeberle, S., Brenner, T., Müller, C., Steinert, C. P., Koltay, P., Gottschlich, N., Reinecke, H., Rühe, J., Zengerle, R., et al. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/2/020 · Cited by 194
Self-citationLaser processing for bio-microfluidics applications (part I)
Khan Malek, C. G. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0514-2 · Cited by 190
Polyimide-based microfluidic devices
Metz, S., Holzer, R., & Renaud, P. (2001) · Lab on a Chip · doi:10.1039/b103896f · Cited by 185
Activated gas plasma surface treatment of polymers for adhesive bonding
Hall, J. R., Westerdahl, C. A. L., Devine, A. T., & Bodnar, M. J. (1969) · Journal of Applied Polymer Science · doi:10.1002/app.1969.070131006 · Cited by 157
Laser processing for bio-microfluidics applications (part II)
Malek, C. K. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0517-z · Cited by 153
Shrinky-Dink microfluidics: 3D polystyrene chips
Chen, C., Breslauer, D. N., Luna, J. I., Grimes, A., Chin, W., Lee, L. P., & Khine, M. (2008) · Lab on a Chip · doi:10.1039/b719029h · Cited by 152
Developments in food packaging technology. Part II. Storage aspects
Smith, J. P., Ramaswamy, H. S., & Simpson, B. K. (1990) · Trends in Food Science & Technology · doi:10.1016/0924-2244(90)90086-e · Cited by 149
3D tissue culture substrates produced by microthermoforming of pre-processed polymer films
Giselbrecht, S., Gietzelt, T., Gottwald, E., Trautmann, C., Truckenmüller, R. K., Weibezahn, K. F., & Welle, A. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8174-8 · Cited by 120
A chip-based platform for the in vitro generation of tissues in three-dimensional organization.
Gottwald, E., Giselbrecht, S., Augspurger, C., Lahni, B., Dambrowsky, N., Truckenmüller, R., Piotter, V., Gietzelt, T., Wendt, O., Pfleging, W., et al. (2007) · Lab on a Chip · doi:10.1039/b618488j · Cited by 100
Surface treatment and characterization: Perspectives to electrophoresis and lab‐on‐chips
Pallandre, A., de Lambert, B., Attia, R., Jonas, A. M., & Viovy, J. (2006) · Electrophoresis · doi:10.1002/elps.200500761 · Cited by 98
Design and Rapid Prototyping of Thin-Film Laminate-Based Microfluidic Devices
Weigl, B. H., Bardell, R. L., Schulte, T., Battrell, F., & Hayenga, J. W. (2001) · Biomedical Microdevices · doi:10.1023/a:1012448412811 · Cited by 97
Dang, F., Shinohara, S., Tabata, O., Yamaoka, Y., Kurokawa, M., Shinohara, Y., Ishikawa, M., & Baba, Y. (2005) · Lab on a Chip · doi:10.1039/b417398h · Cited by 92
Finger-actuated, self-contained immunoassay cassettes
Qiu, X., Thompson, J. A., Chen, Z., Liu, C., Chen, D., Ramprasad, S., Mauk, M. G., Ongagna-Yhombi, S. Y., Barber, C. A., Abrams, W. R., et al. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9334-4 · Cited by 88
Flexible fluidic microchips based on thermoformed and locally modified thin polymer films
Truckenmüller, R. K., Giselbrecht, S., van Blitterswijk, C., Dambrowsky, N., Gottwald, E., Mappes, T., Rolletschek, A., Saile, V., Trautmann, C., Weibezahn, K. F., et al. (2008) · Lab on a Chip · doi:10.1039/b803619e · Cited by 88
A new and emerging technology: Laser-induced surface modification of polymers
Özdemir, M., & Sadıkoğlu, H. (1998) · Trends in Food Science & Technology · doi:10.1016/s0924-2244(98)00035-1 · Cited by 83
Microfluidics: in search of a killer application
Blow, N. S. (2007) · Nature Methods · doi:10.1038/nmeth0807-665 · Cited by 80
Microwave welding of high density polyethylene using intrinsically conductive polyaniline
Wu, C., & Benatar, A. (1997) · Polymer Engineering and Science · doi:10.1002/pen.11717 · Cited by 62
Point-of-care diagnostics: an advancing sector with nontechnical issues
Huckle, D. (2008) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.8.6.679 · Cited by 60
INCREASING FLOW LENGTH IN THIN WALL INJECTION MOLDING USING A RAPIDLY HEATED MOLD
Yao, D., & Kim, B. G. (2002) · Polymer-Plastics Technology and Engineering · doi:10.1080/15256111.2002.12563216 · Cited by 57
Pumping fluids in microfluidic systems using the elastic deformation of poly(dimethylsiloxane)
Weibel, D. B., Siegel, A. C., Lee, A., George, A. H., & Whitesides, G. M. (2007) · Lab on a Chip · doi:10.1039/b714664g · Cited by 56
Structure and Mobility of Lipid Membranes on a Thermoplastic Substrate
Hochrein, M. B., Reich, C., Krause, B., Rädler, J. O., & Nickel, B. A. (2005) · Langmuir · doi:10.1021/la051820y · Cited by 48
The evolution of commercialized glucose sensors in China
Hu, J. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.051 · Cited by 47
Medical and Economic Outcomes of Point-of-Care Testing
Price, C. P. (2002) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2002.040 · Cited by 47
Lab-on-a-print: from a single polymer film to three-dimensional integrated microfluidics
Wang, W., Zhao, S., & Pan, T. (2009) · Lab on a Chip · doi:10.1039/b816287e · Cited by 42
Giselbrecht, S., Gietzelt, T., Gottwald, E., Guber, A. E., Trautmann, C., Truckenmüller, R. K., & Weibezahn, K. F. (2004) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20040824 · Cited by 41
Lancaster, C. A., Kokoris, M. S., Nabavi, M., et al. (2005) · Methods · doi:10.1016/j.ymeth.2005.07.003 · Cited by 37
Utility of lab‐on‐a‐chip technology for high‐throughput nucleic acid and protein analysis
Hawtin, P., Hardern, I. M., Wittig, R., Mollenhauer, J., Poustka, A., Salowsky, R., Wulff, T., Rizzo, C. J., & Wilson, B. (2005) · Electrophoresis · doi:10.1002/elps.200500166 · Cited by 36
A low-cost, disposable card for rapid polymerase chain reaction
Jia, G., Siegrist, J., Deng, C., Zoval, J. V., Stewart, G., Peytavi, R., Huletsky, A., Bergeron, M. G., & Madou, M. J. (2007) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.03.007 · Cited by 28
Emamzadah, S., Petty, T. J., Almeida, V. D., et al. (2009) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909021489 · Cited by 27
Development of a rapid one-step immunochromatographic assay for HCV core antigen detection
Mikawa, A. Y., Tagliavini, S. A., Kenfe, F. R., da Silva, F. H., & da Costa, P. I. (2009) · Journal of Virological Methods · doi:10.1016/j.jviromet.2009.02.013 · Cited by 26
Kokoris, M. S., Nabavi, M., Lancaster, C. A., et al. (2005) · Methods · doi:10.1016/j.ymeth.2005.07.002 · Cited by 22
Rubber-assisted micro forming of polymer thin films
Nagarajan, P., & Yao, D. (2008) · Microsystem Technologies · doi:10.1007/s00542-008-0680-6 · Cited by 21
Bending characteristics of SU-8
Spratley, J. P. F., Ward, M. C. L., & Hall, P. S. (2007) · Micro & Nano Letters · doi:10.1049/mnl:20070022 · Cited by 13
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
Flexible Electronics: The Next Ubiquitous Platform
Nathan, A., Ahnood, A., Cole, M. T., Lee, S., Suzuki, Y., Hiralal, P., Bonaccorso, F., Hasan, T., Garcia-Gancedo, L., Dyadyusha, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2190168 · Cited by 1,000
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Metadata
- Authors
- Focke, M., Kosse, D., Müller, C., Reinecke, H., Zengerle, R., & von Stetten, F.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 11
- Pages
- 1365
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2106342535
- Cited by
- 255
- References
- 72
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.