CoChat

A microfluidic approach for in vitro assessment of interorgan interactions in drug metabolism using intestinal and liver slices

van Midwoud, Paul M., Merema, Marjolijn T., Verpoorte, Elisabeth, Groothuis, Geny M. M. · 2010 · Lab on a Chip

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Over the past two decades, it has become increasingly clear that the intestine, in addition to the liver, plays an important role in the metabolism of xenobiotics. Previously, we developed a microfluidic-based in vitro system for the perifusion of precision-cut liver slices for metabolism studies. In the present study, the applicability of this system for the perifusion of precision-cut intestinal slices, and for the sequential perifusion of intestinal and liver slices, all from rat, was tested to mimic the in vivo first pass situation. Intestinal and liver slices, exposed to the substrates 7-ethoxycoumarin (7-EC), 7-hydroxycoumarin (7-HC) and lidocaine (Li), exhibited similar metabolic rates in the biochip and in the well plates for periods of at least 3 h. The metabolic rate remained the same when two slices were placed in adjacent microchambers and perifused sequentially. In addition, the system has been adapted to sequentially perifuse intestinal and liver tissue slices in a two-compartment co-culture perfusion system with a continuous flow of medium. It becomes possible to direct metabolites or other excreted compounds formed by an intestinal slice in the first compartment to the second compartment containing a liver slice. The intestine does not influence liver metabolism for these substrates. The interplay between these two organs was demonstrated by exposing the slices to the primary bile acid, chenodeoxycholic acid (CDCA). CDCA induced the expression of fibroblast growth factor 15 (FGF15) in the intestinal slice, which resulted in a stronger down-regulation of the enzyme, cytochrome P450 7A1 (CYP7A1), in the liver slice in the second compartment than when the liver slice was exposed to CDCA in a single-microchamber biochip. We thus demonstrate in this paper that intestinal slices, in addition to liver slices, remain functional in the biochip under flow conditions, and that the two-microchamber biochip has great potential for the study of interorgan effects. This is the first example of the incorporation of both liver and intestinal slices in a microfluidic device. Use of this microfluidic system will improve our insight into interorgan interactions and elucidate as yet unknown mechanisms involved in toxicity, gene regulation and drug-drug interactions.

Overview

Integrity signals

Registry

Crossref · 10.1039/c0lc00043d

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Shneider, 2001, J. Pediatr. Gastroenterol. Nutr., 32, 407, 10.1097/00005176-200104000-00002 · doi:10.1097/00005176-200104000-00002 · Paper page

Cited by

See all 207

Metadata

Authors
van Midwoud, P. M., Merema, M. T., Verpoorte, E., & Groothuis, G. M. M.
Affiliations
University of Groningen (NL)
Corresponding author
Groothuis, Geny M. M.
Venue
Lab on a Chip
Published
2010
Volume
10
Issue
20
Pages
2778
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2074545908
Cited by
203
References
29
Citations by year
2026: 3 · 2025: 5 · 2024: 13 · 2023: 4 · 2022: 14 · 2021: 16 · 2020: 16 · 2019: 13 · 2018: 16 · 2017: 17 · 2016: 17 · 2015: 13 · 2014: 19 · 2013: 14 · 2012: 12
FWCI
11.93
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Pharmacogenetics and Drug Metabolism
  • Health Sciences › Medicine › Oncology › Drug Transport and Resistance Mechanisms
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Drug-Induced Hepatotoxicity and Protection
Keywords
microfluidic biochips, precision-cut liver slices, drug metabolism, first-pass metabolism, 7-ethoxycoumarin, umbelliferone, lidocaine, chenodeoxycholic acid, FGF15, CYP7A1, bile acid signaling, xenobiotic metabolism
MeSH terms
Animals, Coumarins, Equipment Design, Intestinal Mucosa, Lidocaine, Liver, Male, Organ Culture Techniques, Flow Injection Analysis, Rats, Wistar, Equipment Failure Analysis, Microfluidic Analytical Techniques, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.