Perfusion-based microfluidic device for three-dimensional dynamic primary human hepatocyte cell culture in the absence of biological or synthetic matrices or coagulants
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We describe a perfusion-based microfluidic device for three-dimensional (3D) dynamic primary human hepatocyte cell culture. The microfluidic device was used to promote and maintain 3D tissue-like cellular morphology and cell-specific functionality of primary human hepatocytes by restoring membrane polarity and hepatocyte transport function in vitro without the addition of biological or synthetic matrices or coagulants. A unique feature of our dynamic cell culture device is the creation of a microenvironment, without the addition of biological or synthetic matrices or coagulants, that promotes the 3D organization of hepatocytes into cord-like structures that exhibit functional membrane polarity as evidenced by the expression of gap junctions and the formation of an extended, functionally active, bile canalicular network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234
A gel-free 3D microfluidic cell culture system
Ong, S.-M., Zhang, C., Toh, Y.-C., Kim, S. H., Foo, H. L., Tan, C. H., van Noort, D., Park, S., & Yu, H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.022 · Cited by 172
A microfluidic platform for 3-dimensional cell culture and cell-based assays
Kim, M. S., Yeon, J. H., & Park, J.-K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9016-4 · Cited by 166
Cited by
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
The nanoparticle biomolecule corona: lessons learned – challenge accepted?
Docter, D., Westmeier, D., Markiewicz, M., Stolte, S., Knauer, S. K., & Stauber, R. H. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00217f · Cited by 693
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
“Recreation of the microarchitecture of the hepatic lobule via micropillar arrays enabled the formation of bile canalicular structures with polarized cells (Goral et al., 2010).”
BackgroundOrgan-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“ALTEX 33(3), 2016 280 hepatocytes (Carraro et al., 2008; Goral et al., 2010; Ho et al., 2006; Leclerc et al., 2004; Lee et al., 2007b; Park et al., 2008; Powers et al., 2002; Toh et al., 2007, 2009), neurons (Rhee et al.”
Microfluidic devices for cell cultivation and proliferation
Tehranirokh, M., Kouzani, A. Z., Francis, P. S., & Kanwar, J. R. (2013) · Biomicrofluidics · doi:10.1063/1.4826935 · Cited by 202
Competency of different cell models to predict human hepatotoxic drugs
Gómez-Lechón, M. J., Tolosa, L., Conde, I., & Donato, M. T. (2014) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425255.2014.967680 · Cited by 199
“The integration of bottom-patterned microstructures into the cell culture channel has resulted in minimized cell spreading and cell surface interactions, which support the re-establishment of cell polarity [52].”
BackgroundMicrofluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Hepatic organoids for microfluidic drug screening
Au, S. H., Chamberlain, M. D., Mahesh, S., Sefton, M. V., & Wheeler, A. R. (2014) · Lab on a Chip · doi:10.1039/c4lc00531g · Cited by 162
Fraczek, J., Bolleyn, J., Vanhaecke, T., Rogiers, V., & Vinken, M. (2013) · Archives of Toxicology · doi:10.1007/s00204-012-0983-3 · Cited by 119
“Microchannels with integrated biomimetic 3D scaffolds on which hepatocytes are seeded, as often seen in microfluidic cell culture systems, are also an example of cellular micropatterning (Goral et al. 2010; Goral and Yuen 2011).”
BackgroundMicroengineered Liver Tissues for Drug Testing
Khetani, S. R., Berger, D. R., Ballinger, K. R., Davidson, M. D., Lin, C., & Ware, B. R. (2015) · SLAS Technology · doi:10.1177/2211068214566939 · Cited by 116
“Goral et al.144 devised a microfluidic device that promotes the 3D organization of hepatocytes into cord-like structures (as in vivo) without the addition of biological or synthetic matrices.”
BackgroundA decade of progress in liver regenerative medicine
Zhang, J., Zhao, X., Liang, L., Li, J., Demirci, U., & Wang, S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.027 · Cited by 111
“of biochemical matrices for two weeks [38].”
Primary Hepatocyte Isolation and Cultures: Technical Aspects, Challenges and Advancements
Kaur, I., Vasudevan, A., Rawal, P., Tripathi, D. M., Ramakrishna, S., Kaur, S., & Sarin, S. K. (2023) · Bioengineering · doi:10.3390/bioengineering10020131 · Cited by 64
Bioartificial livers: a review of their design and manufacture
Tuerxun, K., He, J., Ibrahim, I., Yusupu, Z., Yasheng, A., Xu, Q., Tang, R., Aikebaier, A., Wu, Y., Tuerdi, M., et al. (2022) · Biofabrication · doi:10.1088/1758-5090/ac6e86 · Cited by 24
“Goral et al [169] developed a perfusion-based micro-fluidic device for dynamic culture of PHHs. PHHs in this device exhibited 3D tissue-like cellular morphology and restored membrane polarity and hep-atic functionality.”
Metadata
- Authors
- Goral, V. N., Hsieh, Y.-C., Petzold, O. N., Clark, J. S., Yuen, P. K., & Faris, R. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 24
- Pages
- 3380
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2126089531
- Cited by
- 130
- References
- 4
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.