The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Microfluidic synthesis of advanced microparticles for encapsulation and controlled release
Abstract
We describe droplet microfluidic strategies used to fabricate advanced microparticles that are useful structures for the encapsulation and release of actives; these strategies can be further developed to produce microparticles for advanced drug delivery applications. Microfluidics enables exquisite control in the fabrication of polymer vesicles and thermosensitive microgels from single and higher-order multiple emulsion templates. The strategies used to create the diversity of microparticle structures described in this review, coupled with the scalability of microfluidics, will enable fabrication of large quantities of novel microparticle structures that have potential uses in controlled drug release applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug Delivery Systems: Entering the Mainstream
Allen, T. M., & Cullis, P. R. (2004) · Science · doi:10.1126/science.1095833 · Cited by 4,552
Discher, D. E., & Eisenberg, A. (2002) · Science · doi:10.1126/science.1074972 · Cited by 3,551
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Self-citation(2016) · CRC Press eBooks · doi:10.1201/b12801 · Cited by 2,031
Particle shape: A new design parameter for micro- and nanoscale drug delivery carriers
Champion, J. A., Katare, Y. K., & Mitragotri, S. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.03.022 · Cited by 1,206
Dripping to Jetting Transitions in Coflowing Liquid Streams
Utada, A. S., Fernandez-Nieves, A., Stone, H. A., & Weitz, D. A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.094502 · Cited by 965
Self-citationControllable Monodisperse Multiple Emulsions
Chu, L., Utada, A. S., Shah, R. K., Kim, J., & Weitz, D. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701358 · Cited by 747
Self-citationDrop formation in a co-flowing ambient fluid
Cramer, C., Fischer, P., & Windhab, E. J. (2004) · Chemical Engineering Science · doi:10.1016/j.ces.2004.04.006 · Cited by 538
Microparticles and nanoparticles for drug delivery
Kohane, D. S. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21301 · Cited by 517
Microspheres for controlled release drug delivery
Varde, N. K., & Pack, D. W. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.1.35 · Cited by 448
Shum, H. C., Kim, J.-W., & Weitz, D. A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja802157y · Cited by 445
Self-citationPrecise control of PLG microsphere size provides enhanced control of drug release rate
Berkland, C., King, M., Cox, A., Kim, K. (., & Pack, D. W. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00136-0 · Cited by 400
Fabrication of PLG microspheres with precisely controlled and monodisperse size distributions
Berkland, C., Kim, K. (., & Pack, D. W. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00289-9 · Cited by 336
High throughput production of single core double emulsions in a parallelized microfluidic device
Romanowsky, M. B., Abate, A. R., Rotem, A., Holtze, C., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21033a · Cited by 292
Self-citationDual-drug delivery system based on hydrogel/micelle composites
Wei, L., Cai, C., Lin, J., & Chen, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.006 · Cited by 292
Multicompartment Polymersomes from Double Emulsions
Shum, H. C., Zhao, Y., Kim, S., & Weitz, D. A. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006023 · Cited by 280
Self-citationMultiple Polymersomes for Programmed Release of Multiple Components
Kim, S.-H., Shum, H. C., Kim, J. W., Cho, J.-C., & Weitz, D. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205687k · Cited by 250
Self-citationColloidal Microgels in Drug Delivery Applications
Vinogradov, S. (2006) · Current Pharmaceutical Design · doi:10.2174/138161206779026254 · Cited by 210
Smart Microgel Capsules from Macromolecular Precursors
Seiffert, S., Thiele, J., Abate, A. R., & Weitz, D. A. (2010) · Journal of the American Chemical Society · doi:10.1021/ja102156h · Cited by 206
Self-citationTran, V.-T., Benoît, J.-P., & Venier-Julienne, M.-C. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.01.027 · Cited by 188
Microspheres for Drug Delivery
Kim, K. K., & Pack, D. W. (2006) · Springer eBooks · doi:10.1007/978-0-387-25842-3_2 · Cited by 151
Smart Polymer Based Delivery Systems for Peptides and Proteins
Al‐Tahami, K., & Singh, J. (2007) · Recent Patents on Drug Delivery & Formulation · doi:10.2174/187221107779814113 · Cited by 148
Uniform double-walled polymer microspheres of controllable shell thickness
Berkland, C., Pollauf, E., Pack, D. W., & Kim, K. (. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.01.018 · Cited by 131
A new device for the generation of microbubbles
Gordillo, J. M., Cheng, Z., Gañán‐Calvo, A. M., Márquez, M., & Weitz, D. A. (2004) · Physics of Fluids · doi:10.1063/1.1737739 · Cited by 110
Self-citationThiele, J., Abate, A. R., Shum, H. C., Bachtler, S., Förster, S., & Weitz, D. A. (2010) · Small · doi:10.1002/smll.201000798 · Cited by 110
Self-citationPhotodimers of N-alkyl-3,4-dimethylmaleimides—Product ratios and reaction mechanism
Yu, X., Corten, C. C., Görner, H., Wolff, T. E., & Kuckling, D. (2008) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2008.02.013 · Cited by 25
Cited by
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Hydrogel microparticles for biomedical applications
Daly, A. C., Riley, L., Segura, T., & Burdick, J. A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0148-6 · Cited by 1,249
Drug delivery systems and materials for wound healing applications
Saghazadeh, S., Rinoldi, C., Schot, M., Kashaf, S. S., Sharifi, F., Jalilian, E., Nuutila, K., Giatsidis, G., Mostafalu, P., Derakhshandeh, H., et al. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.04.008 · Cited by 842
Microfluidic fabrication of microparticles for biomedical applications
Li, W., Zhang, L., Ge, X., Xu, B., Zhang, W., Qu, L., Choi, C.-H., Xu, J., Zhang, A., Lee, H., et al. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00263g · Cited by 585
Self-citationLinking synchronization to self-assembly using magnetic Janus colloids
Yan, J., Bloom, M., Bae, S. C., Luijten, E., & Granick, S. (2012) · Nature · doi:10.1038/nature11619 · Cited by 430
Metadata
- Authors
- Duncanson, W. J., Lin, T., Abate, A. R., Seiffert, S., Shah, R. K., & Weitz, D. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 12
- Pages
- 2135
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2143034786
- Cited by
- 370
- References
- 26
- FWCI
- 15.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.