The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Ion dynamics in a trapped ion mobility spectrometer
Open accessAbstract
In the present paper, theoretical simulations and experimental observations are used to describe the ion dynamics in a trapped ion mobility spectrometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
The mobility and diffusion of ions in gases
McDaniel, E. W., & Mason, E. A. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 942
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Silicon cluster ions: Evidence for a structural transition
Jarrold, M. F., & Constant, V. A. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.2994 · Cited by 380
Kolakowski, B. M., & Mester, Z. (2007) · The Analyst · doi:10.1039/b706039d · Cited by 351
Gas-phase separation using a trapped ion mobility spectrometer
Fernandez-Lima, F., Kaplan, D. A., Suetering, J., & Park, M. A. (2011) · International Journal for Ion Mobility Spectrometry · doi:10.1007/s12127-011-0067-8 · Cited by 315
Self-citationHigh-resolution ion mobility measurements
Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147873 · Cited by 299
Gaseous lon mobility in electric fields of arbitrary strength
Viehland, L. A., & Mason, E. A. (1975) · Annals of Physics · doi:10.1016/0003-4916(75)90233-x · Cited by 293
Koeniger, S. L., Merenbloom, S. I., Valentine, S. J., Jarrold, M. F., Udseth, H. R., Smith, R. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac051060w · Cited by 272
Note: Integration of trapped ion mobility spectrometry with mass spectrometry
Fernandez-Lima, F. A., Kaplan, D. A., & Park, M. A. (2011) · Review of Scientific Instruments · doi:10.1063/1.3665933 · Cited by 235
Self-citationGaseous ion mobility and diffusion in electric fields of arbitrary strength
Viehland, L. A., & Mason, E. A. (1978) · Annals of Physics · doi:10.1016/0003-4916(78)90034-9 · Cited by 210
A new, higher resolution, ion mobility mass spectrometer
Kemper, P. R., Dupuis, N. F., & Bowers, M. T. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2009.01.012 · Cited by 195
High-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla
Schaub, T. M., Hendrickson, C. L., Horning, S., Quinn, J. P., Senko, M. W., & Marshall, A. G. (2008) · Analytical Chemistry · doi:10.1021/ac800386h · Cited by 192
Petroleum Crude Oil Characterization by IMS-MS and FTICR MS
Fernandez-Lima, F. A., Becker, C., McKenna, A. M., Rodgers, R. P., Marshall, A. G., & Russell, D. H. (2009) · Analytical Chemistry · doi:10.1021/ac901594f · Cited by 188
Self-citationSeparation of Ions from Explosives in Differential Mobility Spectrometry by Vapor-Modified Drift Gas
Eiceman, G. A., Krylov, E. V., Krylova, N. S., Nazarov, E. G., & Miller, R. A. (2004) · Analytical Chemistry · doi:10.1021/ac035502k · Cited by 186
High-Resolution Ion Cyclotron Mobility Spectrometry
Merenbloom, S. I., Glaskin, R. S., Henson, Z. B., & Clemmer, D. E. (2009) · Analytical Chemistry · doi:10.1021/ac801880a · Cited by 161
Metabolic profiling by ion mobility mass spectrometry (IMMS)
Dwivedi, P., Wu, P., Klopsch, S. J., Puzon, G. J., Xun, L., & Hill, H. H. (2008) · Metabolomics · doi:10.1007/s11306-007-0093-z · Cited by 160
Николаев, Е. Н., Heeren, R. M. A., Popov, A. M., Pozdneev, A. V., & Chingin, K. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3234 · Cited by 81
Chemical standards in ion mobility spectrometry
Fernández‐Maestre, R., Harden, C. S., Ewing, R. G., Crawford, C. L., & Hill, H. H. (2010) · The Analyst · doi:10.1039/b915202d · Cited by 78
Zeleny, J. (1898) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786449808621173 · Cited by 74
Ion Trapping for Ion Mobility Spectrometry Measurements in a Cyclical Drift Tube
Glaskin, R. S., Ewing, M. A., & Clemmer, D. E. (2013) · Analytical Chemistry · doi:10.1021/ac4015066 · Cited by 73
Vautz, W., Slodzynski, R., Hariharan, C., et al. (2012) · Analytical Chemistry · doi:10.1021/ac302752f · Cited by 54
Analysis of bacterial strains with pyrolysis-gas chromatography/differential mobility spectrometry
Prasad, S., Schmidt, H., Lampen, P., Wang, M., Güth, R., Rao, J. V., Smith, G. B., & Eiceman, G. A. (2006) · The Analyst · doi:10.1039/b608127d · Cited by 45
Kim, S., Choi, M. C., Kim, S., Hur, M., Kim, H. S., Yoo, J. S., Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2007) · Analytical Chemistry · doi:10.1021/ac062016z · Cited by 12
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Self-citationIon Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationReview on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Metadata
- Authors
- Hernandez, D. R., DeBord, J. D., Ridgeway, M. E., Kaplan, D. A., Park, M. A., & Fernandez-Lima, F.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 139
- Issue
- 8
- Pages
- 1913-1921
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2143206354
- Cited by
- 267
- References
- 24
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.