Microfluidic titer plate for stratified 3D cell culture
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Human tissues and organs are inherently heterogeneous. Their functionality is determined by the interplay between different cell types, their secondary architecture, vascular system and gradients of signaling molecules and metabolites. Here we propose a stratified 3D cell culture platform, in which adjacent lanes of gels and liquids are patterned by phaseguides to capture this tissue heterogeneity. We demonstrate 3D cell culture of HepG2 hepatocytes under continuous perfusion, a rifampicin toxicity assay and co-culture with fibroblasts. 4T1 breast cancer cells are used to demonstrate invasion and aggregation models. The platform is incorporated in a microtiter plate format that renders it fully compatible with automation and high-content screening equipment. The extended functionality, ease of handling and full compatibility to standard equipment is an important step towards adoption of Organ-on-a-Chip technology for screening in an industrial setting.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent years, techniques which can overcome the abnormal vasculature in the tumor, such as nanoparticle drug delivery and drugs normalizing vascular network, were shown to be able to greatly improve anti-cancer treatment [108-113].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [108]
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [117]
In the citing paper
“Instead of simultaneously culturing various cell types in the same chamber, a separate coculture system grows each cell type in a separate chamber and all the cell-cell interaction is achieved by substance diffusion through the culture media between individual culture chambers [131, 139-148] (Figure 4b).”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [131]
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [117]
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Weaver, V. M., Petersen, O. W., Wang, F., Larabell, C. A., Briand, P., Damsky, C., & Bissell, M. J. (1997) · The Journal of Cell Biology · doi:10.1083/jcb.137.1.231 · Cited by 1,483
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,234
Kenny, P. A., Lee, G. Y., Myers, C. A., Neve, R. M., Semeiks, J. R., Spellman, P. T., Lorenz, K., Lee, E. H., Barcellos‐Hoff, M. H., PETERSEN, O. W., et al. (2008) · eScholarship (California Digital Library) · Cited by 1,039
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Ensembles of engineered cardiac tissues for physiological and pharmacological study: Heart on a chip
Grosberg, A., Alford, P. W., McCain, M. L., & Parker, K. K. (2011) · Lab on a Chip · doi:10.1039/c1lc20557a · Cited by 544
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Cited by
Items 101–189 of 189
Mainardi, A., Carminati, F., Ugolini, G. S., Occhetta, P., Isu, G., Diaz, D. R., Reid, G., Visone, R., Rasponi, M., & Marsano, A. (2021) · Lab on a Chip · doi:10.1039/d1lc00092f · Cited by 25
Hydrogel-based microfluidic incubator for microorganism cultivation and analyses
Puchberger-Enengl, D., van den Driesche, S., Krutzler, C., Keplinger, F., & Vellekoop, M. J. (2015) · Biomicrofluidics · doi:10.1063/1.4913647 · Cited by 23
Beekers, I., van Rooij, T., Verweij, M. D., Versluis, M., de Jong, N., Trietsch, S. J., & Kooiman, K. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2803137 · Cited by 26
“, 4003400B) is a microfluidic system consisting of 40 chips developed for 3-D cell culture [23].”
BackgroundMethodSelf-citationHydrophobic Patterning‐Based 3D Microfluidic Cell Culture Assay
Han, S., Kim, J.-H., Li, R., Ma, A. L., Kwan, V. W.-S., Luong, K., & Sohn, L. L. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800122 · Cited by 26
In vitro Models for Chemical Toxicity: Review of their Applications and Prospects
Rim, K.-T. (2019) · Toxicology and Environmental Health Sciences · doi:10.1007/s13530-019-0402-8 · Cited by 26
Kurth, F., Györvary, E., Heub, S., Ledroit, D., Paoletti, S., Renggli, K., Revol, V., Verhulsel, M., Weder, G., & Loizeau, F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00003-6 · Cited by 31
Phaseguide assisted liquid lamination for magnetic particle-based assays
Phurimsak, C., Yıldırım, E., Tarn, M. D., Trietsch, S. J., Hankemeier, T., Pamme, N., & Vulto, P. (2014) · Lab on a Chip · doi:10.1039/c4lc00139g · Cited by 27
Self-citationZhang, H., Whalley, R. D., Ferreira, A. M., & Dalgarno, K. W. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab7cc4 · Cited by 22
“Reproduced from [108] with permission of The Royal Society of Chemistry.”
Modeling the tumor immune microenvironment for drug discovery using 3D culture
Lee, J. Y., & Chaudhuri, O. (2021) · APL Bioengineering · doi:10.1063/5.0030693 · Cited by 24
Organ-on-a-chip: Quo vademus? Applications and regulatory status
Mendes, M., Morais, A. S., Carlos, A., Sousa, J., Pais, A. A. C. C., Mihaila, S. M., & Vitorino, C. (2025) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2025.114507 · Cited by 24
Ehlers, H., Olivier, T., Trietsch, S. J., Vulto, P., Burton, T. P., & van den Broek, L. J. (2025) · Lab on a Chip · doi:10.1039/d4lc01109k · Cited by 23
Self-citationOrgan-on-a-Chip: A Roadmap for Translational Research in Human and Veterinary Medicine
Surina, S., Chmielewska, A., Pratscher, B., Freund, P., Rodríguez-Rojas, A., & Burgener, I. A. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms262110753 · Cited by 24
Loessberg-Zahl, J., Beumer, J., van den Berg, A., Eijkel, J. C. T., & van der Meer, A. D. (2020) · Micromachines · doi:10.3390/mi11121112 · Cited by 24
“Most commonly, gel confinement is achieved via an array of pillars [12,13], or sometimes via phase guides [14,17].”
BackgroundKimura, H., Nakamura, H., Goto, T., Uchida, W., Uozumi, T., Nishizawa, D., Shinha, K., Sakagami, J., & Doi, K. (2024) · Lab on a Chip · doi:10.1039/d3lc00934c · Cited by 20
Microsensor systems for cell metabolism – from 2D culture to organ-on-chip (2019–2024)
Dornhof, J., Kieninger, J., Rupitsch, S. J., & Weltin, A. (2025) · Lab on a Chip · doi:10.1039/d4lc00437j · Cited by 25
O’Halloran, L., Akinsete, O., Kogan, A. L., Wrona, M., & Mahdi, A. F. (2025) · Frontiers in Pharmacology · doi:10.3389/fphar.2025.1637602 · Cited by 26
Integrated Microphysiological Systems: Transferable Organ Models and Recirculating Flow
Renggli, K., Rousset, N., Lohasz, C., Nguyen, O. T. P., & Hierlemann, A. R. (2019) · Advanced Biosystems · doi:10.1002/adbi.201900018 · Cited by 22
The progressive trend of modeling and drug screening systems of breast cancer bone metastasis
Azar, H. K., Gharibshahian, M., Rostami, M., Mansouri, V., Sabouri, L., Beheshtizadeh, N., & Rezaei, N. (2024) · Journal of Biological Engineering · doi:10.1186/s13036-024-00408-5 · Cited by 23
“In contrast, separate co-culture systems are useful for rapidly recognizing cell types cultured in the device [176].”
BackgroundZanetti, F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00007-3 · Cited by 25
From Single Cells to Engineered and Explanted Tissues
Bergmann, S., & Steinert, M. (2015) · International review of cytology · doi:10.1016/bs.ircmb.2015.06.003 · Cited by 22
Chen, Z., Li, W., Zhang, Y., Yu, M., Shan, L., Yuan, D., Liu, F., & Jin, F. (2016) · Scientific Reports · doi:10.1038/srep38376 · Cited by 18
Lohasz, C., Loretan, J., Sterker, D., Görlach, E., Renggli, K., Argast, P., Frey, O., Wiesmann, M., Wartmann, M., Rausch, M., et al. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.785851 · Cited by 17
“There is a number of alternative perfusion approaches to overcome the use of complex and expensive precision equipment by exploiting gravity (Trietsch et al., 2013; Oleaga et al., 2016; Busche et al., 2020), centrifugal forces (Gorkin et al.”
BackgroundBioreactors and Microfluidics for Osteochondral Interface Maturation
Canadas, R. F., Marques, A. P., Reis, R. L., & Oliveira, J. M. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-76735-2_18 · Cited by 17
Progress towards understanding heterotypic interactions in multi-culture models of breast cancer
Regier, M. C., Alarid, E. T., & Beebe, D. J. (2016) · Integrative Biology · doi:10.1039/c6ib00001k · Cited by 20
Loessberg-Zahl, J., van der Meer, A. D., van den Berg, A., & Eijkel, J. C. T. (2018) · Lab on a Chip · doi:10.1039/c8lc01140k · Cited by 15
Grün, C., Altmann, B., & Gottwald, E. (2020) · Processes · doi:10.3390/pr8121656 · Cited by 16
Okeyo, P. O., Rajendran, S. T., Zór, K., & Boisen, A. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113850 · Cited by 15
Bioinspired Engineering of Organ-on-Chip Devices
Wang, L., Li, Z., Xu, C., & Qin, J. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-9791-2_13 · Cited by 14
Jepsen, M. L., Willumsen, A., Mazzoni, C., Boisen, A., Nielsen, L. H., & Dufva, M. (2020) · Advanced Biosystems · doi:10.1002/adbi.201900289 · Cited by 15
Parkinson’s disease phenotypes in patient specific brain organoids are improved by HP-β-CD treatmentPreprint
Jarazo, J., Barmpa, K., Rosety, I., Smits, L. M., Arias, J., Walter, J., Gomez‐Giro, G., Monzel, A. S., Qing, X., Cruciani, G., et al. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/813089 · Cited by 14
“The media perfusion was achieved by gravity, with an average fluid flow of 1.5μl/h (Trietsch et al, 2013).”
MethodMabrouk, A. S., Ongenae, V., Claessen, D., Brenzinger, S., & Briegel, A. (2023) · Applied and Environmental Microbiology · doi:10.1128/aem.01596-22 · Cited by 13
Gijzen, L., Bokkers, M., Hanamsagar, R., Olivier, T., Burton, T. P., Tool, L. M., Rahman, M. F., Lowman, J., Savova, V., Means, T. K., et al. (2024) · Biofabrication · doi:10.1088/1758-5090/ad9fdf · Cited by 14
Oedit, A., Hankemeier, T., & Lindenburg, P. W. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105741 · Cited by 13
Self-citationOrgan-On-A-Chip Database Revealed—Achieving the Human Avatar in Silicon
Jiang, L., Li, Q., Liang, W., Du, X., Yang, Y., Zhang, Z., Xu, L., Zhang, J., Li, J., Chen, Z., et al. (2022) · Bioengineering · doi:10.3390/bioengineering9110685 · Cited by 17
Bai, H., Olson, K. N. P., Pan, M., Marshall, T., Singh, H., Ma, J., Gilbride, P., Yuan, Y., McCormack, J., Si, L., et al. (2023) · Advanced Science · doi:10.1002/advs.202304332 · Cited by 11
Animal-Free Chemical Safety Assessment
Loizou, G. D. (2016) · Frontiers in Pharmacology · doi:10.3389/fphar.2016.00218 · Cited by 17
Body-on-a-chip systems: Design, fabrication, and applications
Esch, M. B., & Mahler, G. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00011-6 · Cited by 16
Wang, D., Li, Q., Zhou, C., Li, Z., Lu, K., Liu, Y., Xuan, L., & Wang, X. (2024) · Bio-Design and Manufacturing · doi:10.1007/s42242-023-00267-x · Cited by 14
The promise of organotypic hepatic and gastrointestinal models
Vu, L. T., Less, R. R., & Rajagopalan, P. (2014) · Trends in biotechnology · doi:10.1016/j.tibtech.2014.04.006 · Cited by 12
Gu, L., Liu, P., Zhao, W. Y., Fan, Y., Wang, Y., & Chen, P. (2025) · MedMat. · doi:10.1097/mm9.0000000000000016 · Cited by 12
Passive controlled flow for Parkinson's disease neuronal cell culture in 3D microfluidic devices
Kane, K. I. W., Jarazo, J., Moreno, E. L., Fleming, R. M. T., & Schwamborn, J. C. (2020) · Organs-on-a-Chip · doi:10.1016/j.ooc.2020.100005 · Cited by 14
Salehi, A., Naserzadeh, P., Tarighi, P., Afjeh‐Dana, E., Akhshik, M., Jafari, A. H., Mackvandi, P., Ashtari, B., & Mozafari, M. (2023) · Translational Oncology · doi:10.1016/j.tranon.2023.101674 · Cited by 10
Kidney microphysiological models for nephrotoxicity assessment
Mahadeo, A., Yeung, C. K., Himmelfarb, J., & Kelly, E. J. (2022) · Current Opinion in Toxicology · doi:10.1016/j.cotox.2022.03.002 · Cited by 15
Biologically-Inspired Microphysiological Systems
Dehne, E., Hickman, J. J., & Shuler, M. L. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813697-3.00030-5 · Cited by 9
A Macro‐to‐Micro Interface for Performing Comprehensive Microfluidic Cell Culture Assays
Kleine‐Brüggeney, H., Weingarten, R., Bockeloh, F. S., Engwer, C., Fartmann, V., Schäfer, J., Rezaei, M., & Bühren, S. (2021) · Advanced Materials Interfaces · doi:10.1002/admi.202100785 · Cited by 10
Disease Modeling with 3D Cell-Based Assays Using a Novel Flowchip System and High-Content Imaging
Cromwell, E. F., Leung, M., Hammer, M., Thai, A., Rajendra, R., & Sirenko, O. (2021) · SLAS TECHNOLOGY · doi:10.1177/24726303211000688 · Cited by 9
Design principles for dynamic microphysiological systems
Cooper, M. H., Charest, J. L., & Coppeta, J. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00001-3 · Cited by 11
Rane, A., Tate, S., Sumey, J. L., Zhong, Q., Zong, H., Purow, B. W., Caliari, S. R., & Swami, N. S. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00041 · Cited by 10
The Case for Cancer-Associated Fibroblasts: Essential Elements in Cancer Drug Discovery?
Brewer, G., Fortier, A.-M., Park, M., & Moraes, C. (2022) · Future Drug Discovery · doi:10.4155/fdd-2021-0004 · Cited by 8
Design and engineering of multiorgan systems
Renggli, K., & Frey, O. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00012-7 · Cited by 8
Kwon, S., Lee, D., Gopal, S., Ku, A., Moon, H., & Dordick, J. S. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10067 · Cited by 7
Modelling EWS::FLI1 protein fluctuations reveal determinants of tumor plasticity in Ewing sarcoma
Suresh, V., Hafemeister, C., Konstantinou, A., Grissenberger, S., Sturtzel, C., Cidre‐Aranaz, F., Wenninger-Weinzierl, A., Zylka, M. M., Queiroz, K. C. S., Kurek, D., et al. (2026) · EMBO Molecular Medicine · doi:10.1038/s44321-025-00364-7 · Cited by 13
“Invasion assays were conducted using the Organoplate 3-lane 64 (Mimetas B.V.), which consists of 64 chips per plate, each containing three micro fl uidic channels (Trietsch et al, 2013).”
Personalized Models of Biological Barriers and Their Diseases: Recent Progress with Organs‐On‐Chips
Buck, F., Bugter, J., Yorukoglu, G., Dastjerd, M. K., & Winkler, T. E. (2026) · Advanced Biology · doi:10.1002/adbi.202500536 · Cited by 10
Intestinal Epithelium Tubules on a Chip
Kosim, K., Schilt, I., Lanz, H. L., Vulto, P., & Kurek, D. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1693-2_6 · Cited by 6
Self-citationFree-floating epithelial micro-tissue arrays: a low cost and versatile technique
Flood, P. F., Alvarez, L., & Reynaud, E. G. (2016) · Biofabrication · doi:10.1088/1758-5090/8/4/045006 · Cited by 6
Multilayered microfluidic platform for three-dimensional vascularized organ-on-a-chip applications
Zhou, C., Li, Z., Xu, J., Yu, D., Xuan, L., & Wang, X. (2025) · Bio-Design and Manufacturing · doi:10.1631/bdm.2500091 · Cited by 6
“These features exploit the me‐ niscus pinning effect to spatially control hydrogel pattern‐ ing and also maintain diffusional nutrient exchange with the surrounding culture medium [30, 31].”
Pei, J., Sun, Q., Yi, Z., Li, Q., & Wang, X. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab68b2 · Cited by 6
Nanoemulsions as Carriers for Natural Antioxidants: Formulation Development and Optimisation
Nikolić, I., Gledović, A., Tamburić, S., Major, T., & Savic, S. D. (2020) · Food bioactive ingredients · doi:10.1007/978-3-030-62052-3_4 · Cited by 9
Capillary Pinning Assisted Patterning of Cell-Laden Hydrogel Microarrays in Microchips
Gümüşcü, B., & Eijkel, J. C. T. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-7792-5_18 · Cited by 5
Vázquez‐Aristizabal, P., Arriola-Alvarez, I., Henriksen‐Lacey, M., Alonso‐Martín, S., van den Broek, L., Liz‐Marzán, L. M., & Izeta, A. (2026) · ACS Applied Bio Materials · doi:10.1021/acsabm.5c02329 · Cited by 5
“24 By combining dECMs with the OrganoPlate, the simultaneous perfusion of 64 microtumors is feasible, potentially leading to a broad range of uses in oncology and in other laboratories worldwide. dECM was obtained as described in Va ́ zquez-Aristizabal et al. 25”
Joshi, T., Chan, Y. O., Qiao, Z., Kheirandish, L., Gozal, D., & Khalyfa, A. (2025) · Experimental Neurology · doi:10.1016/j.expneurol.2025.115188 · Cited by 3
Ni, K., Che, B., Yang, C., Qin, Y., Gu, R., Wang, C., Luo, M., & Deng, L. (2022) · Frontiers in Pharmacology · doi:10.3389/fphar.2022.1033043 · Cited by 3
“The organoplate is an organ-on-a-chip platform comprising 96 microchambers that can be used for 3D cell culture (Trietsch et al., 2013).”
BackgroundMicrofluidic devices and their applicability to cell studies
Fernandes, A. C., Semenova, D., & Grundtvig, I. P. R. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-822482-3.00003-8 · Cited by 2
A “Kidney-on-the-Chip” Model Composed of Primary Human Tubular, Endothelial, and White Blood Cells
Marschner, J. A., Martin, L., Wilken, G. J., Melica, M. E., & Anders, H. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3179-9_8 · Cited by 3
Gupta, B., Malviya, R., Srivastava, S., Ahmad, I. S., Rab, S. O., & Uniyal, P. (2024) · Current Pharmaceutical Design · doi:10.2174/0113816128305296240523112043 · Cited by 3
Suresh, V., Hafemeister, C., Konstantinou, A., Grissenberger, S., Sturtzel, C., Cidre‐Aranaz, F., Wenninger-Weinzierl, A., Zylka, M. M., Queiroz, K. C. S., Kurek, D., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.03.647002 · Cited by 3
Pruett, L. J., Bahlmann, L. C., Ogi, R., Jiao, A., Roy, P., Johnson, M., Trumper, D. L., & Griffith, L. G. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202504936 · Cited by 4
“Although more challenging to prototype (but ultimately amenable to large scale production), chips made from thermoplastic materials resist the absorption of lipophilic compounds, hence such hard plastic chips are emerging as standards in practical applications in drug development [11, 16, 17].”
Coliaie, P., Bhawnani, R. R., Ali, R., Kelkar, M. S., Korde, A., Langston, M., Liu, C., Nazemifard, N., Patience, D. B., Rosenbaum, T., et al. (2023) · ACS Omega · doi:10.1021/acsomega.3c05478 · Cited by 2
“6,7 With the advances of miniaturized systems, screening techniques have evolved to accommodate multiple experiments in a single device.”
Automated microuidic cell culture of stem cell derived dopaminergic neurons in Parkinson’s diseasePreprint
Kane, K. I. W., Moreno, E. L., Hachi, S., Walter, M., Jarazo, J., Hankemeier, T., Vulto, P., Schwamborn, J. C., Thoma, M., & Fleming, R. M. T. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/209957 · Cited by 2
“We previously developed a microfluidic titer plate for three dimensional microfluidic cell culture, called OrganoPlate [28].”
BackgroundMethodInfluentialSelf-citationAdvances in microfluidic chips targeting toxic aggregation proteins for neurodegenerative diseases
Li, L., Lei, T., Xing, C., & Du, H. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.128308 · Cited by 2
Yamazaki, M., Kobayashi, Y., & Sato, K. (2025) · Micromachines · doi:10.3390/mi16030324 · Cited by 1
“Trietsch et al. developed a device to solve this problem where the gel channel for cell culture and the adjacent medium channel are compartmentalized by a 30 µ m high phase guide [12].”
Hydrogel Confinement Strategies for 3D Cell Culture in Microfluidic Systems
Kim, S., Lee, M. S., & Lee, S. K. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501909 · Cited by 6
Characterizing Microbubble‐Mediated Permeabilization in a Vessel‐on‐a‐Chip Model
Meijlink, B., Collado‐Lara, G., Bishard, K., Conboy, J. P., Langeveld, S. A. G., Koenderink, G. H., van der Steen, A. F. W., de Jong, N., Beekers, I., Trietsch, S. J., et al. (2024) · Small · doi:10.1002/smll.202407550 · Cited by 3
Self-citationMasereeuw, R., Vriend, J., & Wilmer, M. J. G. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801734-0.00082-5 · Cited by 1
Aqueous Biphasic 3D Cell Culture Micro-Technology
Atefi, E. (2015) · OhioLink ETD Center (Ohio Library and Information Network)
Predictive and translational models for renal drug safety evaluation
Bajaj, P., Masereeuw, R., McDuffie, J. E., & Wagoner, M. P. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-820018-6.00018-1
Organ-on-a-chip Applications using Collagen Tubular Constructs
Chow, K. (2020) · TSpace (University of Toronto)
Microengineered arterial wall-on-a-chip to model atherosclerosis
Su, C. (2021) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/155569
Futuristic Aspects of Human Organ on a Chip
Dufva, M. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_11
Paternoster, S., Nicolas, A., Schavemaker, F., Rabussier, G., Trietsch, S. J., Lanz, H. L., & Vulto, P. (2022) · Toxicology Letters · doi:10.1016/j.toxlet.2022.07.785
Self-citationMesquita, M., Andrade, R. J., & Cubero, F. J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95262-0.00009-7
Multilayered modular microfluidic platform for 3D vascularized organ-on-a-chip applicationPreprint
Wang, X. L., Zhou, C., Li, Z., Xu, J., Yu, D., & Xuan, L. (2024) · Research Square · doi:10.21203/rs.3.rs-5304520/v1
Expanding the capillarics toolbox: 3D-printed microfluidic phaseguides and self-coalescence modulesPreprint
Craig, C. A., Leong, K. M., Lin, C. H., Chang, M. M., & Olanrewaju, A. O. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.12.21.629531 · Cited by 1
Space of Disse on Chip Model for Study of Hepatic Toxicity and Inflammation
Mesic, A. (2025) · theses.fr (ABES) · doi:10.70675/4c19917ez1d50z4ac8za1a5zd5c8d942f244
Chong, Z., Tang, H., Zhang, Y., Ouyang, J., Zhu, J., Chen, Z., Liu, X., & Gu, Z. (2026) · Biomedical Materials · doi:10.1088/1748-605x/ae722d
Liver lobule models incorporating the space of Disse and their applications
Mesic, A., Bensalem, S., Pioufle, B. L., Duclos‐Vallée, J., & Messina, A. (2026) · Biomicrofluidics · doi:10.1063/5.0331517
From flow to form: structuring and patterning hydrogels using microfluidic approaches
Bouker, E. E., Brown, L. G., Novak, E. N., Lin, A., Whitten, J. M., Viswanathan, A. R., Milton, L. A., Alizai, M. Y., Park, S., Lee, J., et al. (2026) · Lab on a Chip · doi:10.1039/d6lc00386a · Cited by 1
Recent trends in microfluidic platforms for body-on-a-chip systems
Kamei, K., Matsumoto, K., Matsunaga, Y. T., 박민, & Takayama, S. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-16110-0.00030-3
Metadata
- Authors
- Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P.
- Affiliations
- Leiden University (NL)
- Mimetas (Netherlands) (NL)
- Corresponding author
- Trietsch, Sebastiaan J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 18
- Pages
- 3548
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2140405965
- Semantic Scholar
- 32041ad545828bc47d456991dace70c5a80c1ea4
- Cited by
- 189
- References
- 44
- Citations by year
- 2026: 8 · 2025: 14 · 2024: 12 · 2023: 16 · 2022: 12 · 2021: 23 · 2020: 17 · 2019: 19 · 2018: 24 · 2017: 17 · 2016: 8 · 2015: 9 · 2014: 7 · 2013: 3
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Leids Universitair Medisch Centrum
- Stichting voor de Technische Wetenschappen
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- tissue heterogeneity, hepatocytes, HepG2 cells, 4T1 cells, tumor invasion, cell aggregation, organ-on-a-chip, high-content screening, continuous perfusion
- MeSH terms
- Automation, Cell Movement, Cell Survival, Fibroblasts, Humans, Rifampin, Microscopy, Confocal, Coculture Techniques, Cell Culture Techniques, Cell Line, Tumor, Microfluidic Analytical Techniques, Hep G2 Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.