Microfluidic titer plate for stratified 3D cell culture
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Human tissues and organs are inherently heterogeneous. Their functionality is determined by the interplay between different cell types, their secondary architecture, vascular system and gradients of signaling molecules and metabolites. Here we propose a stratified 3D cell culture platform, in which adjacent lanes of gels and liquids are patterned by phaseguides to capture this tissue heterogeneity. We demonstrate 3D cell culture of HepG2 hepatocytes under continuous perfusion, a rifampicin toxicity assay and co-culture with fibroblasts. 4T1 breast cancer cells are used to demonstrate invasion and aggregation models. The platform is incorporated in a microtiter plate format that renders it fully compatible with automation and high-content screening equipment. The extended functionality, ease of handling and full compatibility to standard equipment is an important step towards adoption of Organ-on-a-Chip technology for screening in an industrial setting.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent years, techniques which can overcome the abnormal vasculature in the tumor, such as nanoparticle drug delivery and drugs normalizing vascular network, were shown to be able to greatly improve anti-cancer treatment [108-113].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [108]
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [117]
In the citing paper
“Instead of simultaneously culturing various cell types in the same chamber, a separate coculture system grows each cell type in a separate chamber and all the cell-cell interaction is achieved by substance diffusion through the culture media between individual culture chambers [131, 139-148] (Figure 4b).”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [131]
In the citing paper
“Endothelial cells, fibroblasts, and immune cells are the three main cell types which appear in most cancers and are vital components in enhancing the drug resistance of tumors [103, 114-120].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [117]
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Weaver, V. M., Petersen, O. W., Wang, F., Larabell, C. A., Briand, P., Damsky, C., & Bissell, M. J. (1997) · The Journal of Cell Biology · doi:10.1083/jcb.137.1.231 · Cited by 1,483
Abbott, A. (2003) · Nature · doi:10.1038/424870a · Cited by 1,234
Kenny, P. A., Lee, G. Y., Myers, C. A., Neve, R. M., Semeiks, J. R., Spellman, P. T., Lorenz, K., Lee, E. H., Barcellos‐Hoff, M. H., PETERSEN, O. W., et al. (2008) · eScholarship (California Digital Library) · Cited by 1,039
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Ensembles of engineered cardiac tissues for physiological and pharmacological study: Heart on a chip
Grosberg, A., Alford, P. W., McCain, M. L., & Parker, K. K. (2011) · Lab on a Chip · doi:10.1039/c1lc20557a · Cited by 544
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
A multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Perfused multiwell plate for 3D liver tissue engineering
Domansky, K., Inman, W., Serdy, J., Dash, A., Lim, M. H. M., & Griffith, L. G. (2010) · Lab Chip · doi:10.1039/b913221j · Cited by 444
Sung, J. H., & Shuler, M. L. (2009) · Lab on a Chip · doi:10.1039/b901377f · Cited by 431
Microscale 3-D hydrogel scaffold for biomimetic gastrointestinal (GI) tract model
Sung, J. H., Yu, J., Luo, D., Shuler, M. L., & March, J. C. (2011) · Lab Chip · doi:10.1039/c0lc00273a · Cited by 320
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209905110 · Cited by 304
Axon diodes for the reconstruction of oriented neuronal networks in microfluidic chambers
Peyrin, J.-M., Deleglise, B., Saias, L., Vignes, M., Gougis, P., Magnifico, S., Betuing, S., Pietri, M., Caboche, J., Vanhoutte, P., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20014c · Cited by 276
Unraveling the microenvironmental influences on the normal mammary gland and breast cancer
Weigelt, B., & Bissell, M. J. (2008) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2008.03.013 · Cited by 273
Sung, K. E., Yang, N., Pehlke, C., Keely, P. J., Eliceiri, K. W., Friedl, A., & Beebe, D. J. (2011) · Integr. Biol. · doi:10.1039/c0ib00063a · Cited by 226
Phaseguides: a paradigm shift in microfluidic priming and emptying
Vulto, P., Podszun, S., Meyer, P., Hermann, C., Manz, A., & Urban, G. A. (2011) · Lab on a Chip · doi:10.1039/c0lc00643b · Cited by 222
Self-citationDouville, N. J., Zamankhan, P., Tung, Y.-C., Li, R., Vaughan, B. L., Tai, C.-F., White, J., Christensen, P. J., Grotberg, J. B., & Takayama, S. (2011) · Lab Chip · doi:10.1039/c0lc00251h · Cited by 216
Fey, S. J., & Wrzesinski, K. (2012) · Toxicological Sciences · doi:10.1093/toxsci/kfs122 · Cited by 188
Microfluidic channel fabrication in dry film resist for production and prototyping of hybrid chips
Vulto, P., Glade, N., Altomare, L., Bablet, J., Tin, L. D., Medoro, G., Chartier, I., Manaresi, N., Tartagni, M., & Guerrieri, R. (2005) · Lab on a Chip · doi:10.1039/b411885e · Cited by 187
Self-citationJang, K.-J., Cho, H. S., Kang, D. H., Bae, W. G., Kwon, T.-H., & Suh, K.-Y. (2011) · Integr. Biol. · doi:10.1039/c0ib00018c · Cited by 177
Imura, Y., Sato, K., & Yoshimura, E. (2010) · Analytical Chemistry · doi:10.1021/ac100806x · Cited by 172
In vitro analysis of a hepatic device with intrinsic microvascular-based channels
Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., et al. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9194-3 · Cited by 168
Bile canaliculi formation by aligning rat primary hepatocytes in a microfluidic device
Nakao, Y., Kimura, H., Sakai, Y., & Fujii, T. (2011) · Biomicrofluidics · doi:10.1063/1.3580753 · Cited by 162
Goral, V. N., Hsieh, Y., Petzold, O. N., Clark, J. S., Yuen, P. K., & Faris, R. A. (2010) · Lab on a Chip · doi:10.1039/c0lc00135j · Cited by 133
Co-culture of neurons and glia in a novel microfluidic platform
Majumdar, D., Gao, Y., Li, D., & Webb, D. J. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.024 · Cited by 121
Gao, Y., Majumdar, D., Jovanović, B., Shaifer, C. A., Lin, P. C., Zijlstra, A., Webb, D. J., & Li, D. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9523-9 · Cited by 113
Puleo, C. M., McIntosh Ambrose, W., Takezawa, T., Elisseeff, J., & Wang, T.-H. (2009) · Lab on a Chip · doi:10.1039/b908332d · Cited by 94
Microfluidic array for three-dimensional perfusion culture of human mammary epithelial cells
Chen, S.-Y. C., Hung, P. J., & Lee, P. J. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9545-3 · Cited by 75
Vulto, P., Huesgen, T., Albrecht, B., & Urban, G. A. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/7/077001 · Cited by 75
Self-citationMa, H., Liu, T., Qin, J., & Lin, B. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900776 · Cited by 66
Breast on-a-chip: mimicry of the channeling system of the breast for development of theranostics
Grafton, M. M. G., Wang, L., Vidi, P.-A., Leary, J., & Lelièvre, S. A. (2011) · Integrative Biology · doi:10.1039/c0ib00132e · Cited by 61
Enrichment of viable bacteria in a micro-volume by free-flow electrophoresis
Podszun, S., Vulto, P., Heinz, H., Hakenberg, S., Hermann, C., Hankemeier, T., & Urban, G. A. (2011) · Lab on a Chip · doi:10.1039/c1lc20575g · Cited by 61
Self-citationWrzesinski, K., & Fey, S. J. (2012) · Toxicology Research · doi:10.1039/c2tx20060k · Cited by 57
A microfluidic approach for high efficiency extraction of low molecular weight RNA
Vulto, P., Dame, G., Maier, U., Makohliso, S., Podszun, S., Zahn, P., & Urban, G. A. (2010) · Lab Chip · doi:10.1039/b913481f · Cited by 56
Self-citationMicrofluidic concentration of bacteria by on-chip electrophoresis
Puchberger-Enengl, D., Podszun, S., Heinz, H., Hermann, C., Vulto, P., & Urban, G. A. (2011) · Biomicrofluidics · doi:10.1063/1.3664691 · Cited by 56
Self-citationHuesgen, T., Lenk, G., Albrecht, B., Vulto, P., Lemke, T., & Woias, P. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.06.008 · Cited by 44
Self-citationLiver-Assist Device With a Microfluidics-Based Vascular Bed in an Animal Model
Hsu, W., Carraro, A., Kulig, K. M., Miller, M. L., Mofrad, M. R. K., Weinberg, E. J., Entabi, F., Albadawi, H., Watkins, M. T., Borenstein, J. T., et al. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181e982ba · Cited by 35
Selective sample recovery of DEP-separated cells and particles by phaseguide-controlled laminar flow
Vulto, P., Medoro, G., Altomare, L., Urban, G. A., Tartagni, M., Guerrieri, R., & Manaresi, N. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/9/013 · Cited by 34
Self-citationKenny, P. A., Lee, G. Y., Myers, C. A., Neve, R. M., Semeiks, J. R., Spellman, P. T., Lorenz, K., Lee, E. H., Barcellos-Hoff, M. H., Petersen, O. W., et al. (2007) · Molecular Oncology · doi:10.1016/j.molonc.2007.02.004 · Cited by 2
Cited by
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
“…many companies have emerged that offer standard and customized microfluidic cell culture platforms, with chips fabricated from a wide range of materials (See Table 4), some of which overcome certain disadvantages of PDMS, for instance compatibility with long term culture (Trietsch et al., 2013).”
BackgroundAdvances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Metadata
- Authors
- Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P.
- Affiliations
- Leiden University (NL)
- Mimetas (Netherlands) (NL)
- Corresponding author
- Trietsch, Sebastiaan J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 18
- Pages
- 3548
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2140405965
- Semantic Scholar
- 32041ad545828bc47d456991dace70c5a80c1ea4
- Cited by
- 189
- References
- 44
- Citations by year
- 2026: 8 · 2025: 14 · 2024: 12 · 2023: 16 · 2022: 12 · 2021: 23 · 2020: 17 · 2019: 19 · 2018: 24 · 2017: 17 · 2016: 8 · 2015: 9 · 2014: 7 · 2013: 3
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Leids Universitair Medisch Centrum
- Stichting voor de Technische Wetenschappen
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- tissue heterogeneity, hepatocytes, HepG2 cells, 4T1 cells, tumor invasion, cell aggregation, organ-on-a-chip, high-content screening, continuous perfusion
- MeSH terms
- Automation, Cell Movement, Cell Survival, Fibroblasts, Humans, Rifampin, Microscopy, Confocal, Coculture Techniques, Cell Culture Techniques, Cell Line, Tumor, Microfluidic Analytical Techniques, Hep G2 Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.