The DOI matches its Crossref record.
A microfluidic platform for generating large-scale nearly identical human microphysiological vascularized tissue arrays
Open accessAbstract
This paper reports a polydimethylsiloxane microfluidic model system that can develop an array of nearly identical human microtissues with interconnected vascular networks. The microfluidic system design is based on an analogy with an electric circuit, applying resistive circuit concepts to design pressure dividers in serially-connected microtissue chambers. A long microchannel (550, 620 and 775 mm) creates a resistive circuit with a large hydraulic resistance. Two media reservoirs with a large cross-sectional area and of different heights are connected to the entrance and exit of the long microchannel to serve as a pressure source, and create a near constant pressure drop along the long microchannel. Microtissue chambers (0.12 μl) serve as a two-terminal resistive component with an input impedance >50-fold larger than the long microchannel. Connecting each microtissue chamber to two different positions along the long microchannel creates a series of pressure dividers. Each microtissue chamber enables a controlled pressure drop of a segment of the microchannel without altering the hydrodynamic behaviour of the microchannel. The result is a controlled and predictable microphysiological environment within the microchamber. Interstitial flow, a mechanical cue for stimulating vasculogenesis, was verified by finite element simulation and experiments. The simplicity of this design enabled the development of multiple microtissue arrays (5, 12, and 30 microtissues) by co-culturing endothelial cells, stromal cells, and fibrin within the microchambers over two and three week periods. This methodology enables the culturing of a large array of microtissues with interconnected vascular networks for biological studies and applications such as drug development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 28
- Griffith, 2006, Nat. Rev. Mol. Cell Biol., 7, 211, 10.1038/nrm1858 · DOI · Paper page
- Chung, 2010, Ann. Biomed. Eng., 38, 1164, 10.1007/s10439-010-9899-3 · DOI
- Chung, 2009, Lab Chip, 9, 269, 10.1039/B807585A · DOI · Paper page
- Shin, 2011, Lab Chip, 11, 2175, 10.1039/c1lc20039a · DOI · Paper page
- Chung, 2009, Adv. Mater., 21, 4863, 10.1002/adma.200901727 · DOI
- Chrobak, 2006, Microvasc. Res., 71, 185, 10.1016/j.mvr.2006.02.005 · DOI · Paper page
- Borenstein, 2007, Tissue Eng., 13, 1837, 10.1089/ten.2006.0156 · DOI · Paper page
- Shin, 2004, Biomed. Microdevices, 6, 269, 10.1023/B:BMMD.0000048559.29932.27 · DOI · Paper page
- Berthiera, 2007, Lab Chip, 7, 1475, 10.1039/b707637a · DOI · Paper page
- Sudo, 2009, FASEB J., 23, 2155, 10.1096/fj.08-122820 · DOI · Paper page
- Jaasma, 2008, J. Biotechnol., 133, 490, 10.1016/j.jbiotec.2007.11.010 · doi:10.1016/j.jbiotec.2007.11.010
- Hegab, 2013, Biomicrofluidics, 7, 021502, 10.1063/1.4799966 · DOI
- Bonvin, 2010, Biotechnol. Bioeng., 105, 982, 10.1002/bit.22608 · DOI
- Nga, 2004, Microvasc. Res., 68, 258, 10.1016/j.mvr.2004.08.002 · DOI · Paper page
- Helm, 2005, Proc. Natl. Acad. Sci. U. S. A., 102, 15779, 10.1073/pnas.0503681102 · DOI · Paper page
- Hsu, 2013, Lab Chip, 13, 81, 10.1039/C2LC40787F · DOI
- Oh, 2012, Lab Chip, 12, 515, 10.1039/C2LC20799K · DOI · Paper page
- Walker, 2007, Lab Chip, 7, 226, 10.1039/B608990A · DOI
- Lee, 2009, Lab Chip, 9, 709, 10.1039/B813582G · DOI
- Jeon, 2000, Langmuir, 16, 8311, 10.1021/la000600b · DOI · Paper page
- Hung, 2005, Biotechnol. Bioeng., 89, 1, 10.1002/bit.20289 · DOI · Paper page
- Kim, 2011, Lab Chip, 11, 874, 10.1039/c0lc00516a · DOI
- Moya, 2013, Tissue Eng., Part C, 10.1089/ten.TEC.2012.0430 · DOI · Paper page
- Griffith, 2005, Tissue Eng., 11, 257, 10.1089/ten.2005.11.257 · DOI · Paper page
- Cox, 1986, J. Polym. Sci., Part A: Polym. Chem., 24, 621, 10.1002/pola.1986.080240405 · DOI
- Cho, 2007, J. Colloid Interface Sci., 306, 379, 10.1016/j.jcis.2006.10.077 · DOI · Paper page
- Chen, 2010, Tissue Eng. A, 16, 585, 10.1089/ten.tea.2009.0491 · DOI · Paper page
- Kamei, 2006, Nature, 442, 453, 10.1038/nature04923 · DOI · Paper page
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Vascularization and Angiogenesis in Tissue Engineering: Beyond Creating Static Networks
Rouwkema, J., & Khademhosseini, A. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.03.002 · Cited by 651
Consensus guidelines for the use and interpretation of angiogenesis assays
Nowak-Sliwinska, P., Alitalo, K., Allen, E., Anisimov, A., Aplin, A. C., Auerbach, R., Augustin, H. G., Bates, D. O., van Beijnum, J. R., Bender, R. H. F., et al. (2018) · Angiogenesis · doi:10.1007/s10456-018-9613-x · Cited by 590
Self-citationOpportunities and challenges of translational 3D bioprinting
Murphy, S. V., De Coppi, P., & Atala, A. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0471-7 · Cited by 563
Engineered In Vitro Disease Models
Benam, K. H., Dauth, S., Hassell, B., Herland, A., Jain, A., Jang, K.-J., Karalis, K., Kim, H. J., MacQueen, L., Mahmoodian, R., et al. (2015) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-012414-040418 · Cited by 554
Microfluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
3D microtumors in vitro supported by perfused vascular networks
Sobrino, A., Phan, D. T. T., Datta, R., Wang, X., Hachey, S. J., Romero-López, M., Gratton, E., Lee, A. P., George, S. C., & Hughes, C. C. W. (2016) · Scientific Reports · doi:10.1038/srep31589 · Cited by 387
Self-citationPattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., et al. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02502-2 · Cited by 330
Microfluidic techniques for development of 3D vascularized tissue
Hasan, A., Paul, A., Vrana, N. E., Zhao, X., Memic, A., Hwang, Y.-S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.091 · Cited by 282
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Microfluidics Enabled Bottom-Up Engineering of 3D Vascularized Tumor for Drug Discovery
Agarwal, P., Wang, H., Sun, M., Xu, J., Zhao, S., Liu, Z., Gooch, K. J., Zhao, Y., Lu, X., & He, X. (2017) · ACS Nano · doi:10.1021/acsnano.7b00824 · Cited by 168
A review of microfluidic approaches for investigating cancer extravasation during metastasis
Ma, Y.-H. V., Middleton, K., You, L., & Sun, Y. (2018) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.104 · Cited by 154
Review: in vitro microvessel models
Bogorad, M. I., DeStefano, J., Karlsson, J., Wong, A. D., Gerecht, S., & Searson, P. C. (2015) · Lab on a Chip · doi:10.1039/c5lc00832h · Cited by 145
Hachey, S. J., Movsesyan, S., Nguyen, Q. H., Burton-Sojo, G., Tankazyan, A., Wu, J., Hoang, T., Zhao, D., Wang, S., Hatch, M. M., et al. (2021) · Lab on a Chip · doi:10.1039/d0lc01216e · Cited by 124
Applications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
Self-citationXiao, Y., Kim, D., Dura, B., Zhang, K., Yan, R., Li, H., Han, E., Ip, J., Zou, P., Liu, J., et al. (2019) · Advanced Science · doi:10.1002/advs.201801531 · Cited by 115
Wang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
Recapitulating the vasculature using ORGAN-ON-CHIP technology
Pollet, A. M. A. O., & den Toonder, J. M. J. (2020) · Bioengineering · doi:10.3390/bioengineering7010017 · Cited by 73
Alonzo, L. F., Moya, M. L., Shirure, V. S., & George, S. C. (2015) · Lab on a Chip · doi:10.1039/c5lc00507h · Cited by 66
Self-citationHeylman, C., Sobrino, A., Shirure, V. S., Hughes, C. C., & George, S. C. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214525295 · Cited by 53
Self-citationAdvances in microfluidic 3D cell culture for preclinical drug development
(2022) · Progress in Molecular Biology and Translational Science · doi:10.1016/bs.pmbts.2021.07.022 · Cited by 23
Structure-based design of CDC42 effector interaction inhibitors for the treatment of cancer
Jahid, S., Ortega, J. A., Vuong, L. M., Acquistapace, I. M., Hachey, S. J., Flesher, J. L., La Serra, M. A., Brindani, N., La Sala, G., Manigrasso, J., et al. (2022) · Cell Reports · doi:10.1016/j.celrep.2022.110641 · Cited by 21
Self-citation
Metadata
- Authors
- Hsu, Y.-H., Moya, M. L., Hughes, C. C. W., George, S. C., & Lee, A. P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 15
- Pages
- 2990
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2024343337
- Cited by
- 192
- References
- 0
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.