Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record.

A microfluidic platform for generating large-scale nearly identical human microphysiological vascularized tissue arrays

Open access
Hsu, Yu-Hsiang, Moya, Monica L., Hughes, Christopher C. W., George, Steven C., Lee, Abraham P. · 2013 · Lab on a Chip

Abstract

This paper reports a polydimethylsiloxane microfluidic model system that can develop an array of nearly identical human microtissues with interconnected vascular networks. The microfluidic system design is based on an analogy with an electric circuit, applying resistive circuit concepts to design pressure dividers in serially-connected microtissue chambers. A long microchannel (550, 620 and 775 mm) creates a resistive circuit with a large hydraulic resistance. Two media reservoirs with a large cross-sectional area and of different heights are connected to the entrance and exit of the long microchannel to serve as a pressure source, and create a near constant pressure drop along the long microchannel. Microtissue chambers (0.12 μl) serve as a two-terminal resistive component with an input impedance >50-fold larger than the long microchannel. Connecting each microtissue chamber to two different positions along the long microchannel creates a series of pressure dividers. Each microtissue chamber enables a controlled pressure drop of a segment of the microchannel without altering the hydrodynamic behaviour of the microchannel. The result is a controlled and predictable microphysiological environment within the microchamber. Interstitial flow, a mechanical cue for stimulating vasculogenesis, was verified by finite element simulation and experiments. The simplicity of this design enabled the development of multiple microtissue arrays (5, 12, and 30 microtissues) by co-culturing endothelial cells, stromal cells, and fibrin within the microchambers over two and three week periods. This methodology enables the culturing of a large array of microtissues with interconnected vascular networks for biological studies and applications such as drug development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3lc50424g

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 28

  1. Griffith, 2006, Nat. Rev. Mol. Cell Biol., 7, 211, 10.1038/nrm1858 · DOI · Paper page
  2. Chung, 2010, Ann. Biomed. Eng., 38, 1164, 10.1007/s10439-010-9899-3 · DOI
  3. Chung, 2009, Lab Chip, 9, 269, 10.1039/B807585A · DOI · Paper page
  4. Shin, 2011, Lab Chip, 11, 2175, 10.1039/c1lc20039a · DOI · Paper page
  5. Chung, 2009, Adv. Mater., 21, 4863, 10.1002/adma.200901727 · DOI
  6. Chrobak, 2006, Microvasc. Res., 71, 185, 10.1016/j.mvr.2006.02.005 · DOI · Paper page
  7. Borenstein, 2007, Tissue Eng., 13, 1837, 10.1089/ten.2006.0156 · DOI · Paper page
  8. Shin, 2004, Biomed. Microdevices, 6, 269, 10.1023/B:BMMD.0000048559.29932.27 · DOI · Paper page
  9. Berthiera, 2007, Lab Chip, 7, 1475, 10.1039/b707637a · DOI · Paper page
  10. Sudo, 2009, FASEB J., 23, 2155, 10.1096/fj.08-122820 · DOI · Paper page
  11. Jaasma, 2008, J. Biotechnol., 133, 490, 10.1016/j.jbiotec.2007.11.010 · doi:10.1016/j.jbiotec.2007.11.010
  12. Hegab, 2013, Biomicrofluidics, 7, 021502, 10.1063/1.4799966 · DOI
  13. Bonvin, 2010, Biotechnol. Bioeng., 105, 982, 10.1002/bit.22608 · DOI
  14. Nga, 2004, Microvasc. Res., 68, 258, 10.1016/j.mvr.2004.08.002 · DOI · Paper page
  15. Helm, 2005, Proc. Natl. Acad. Sci. U. S. A., 102, 15779, 10.1073/pnas.0503681102 · DOI · Paper page
  16. Hsu, 2013, Lab Chip, 13, 81, 10.1039/C2LC40787F · DOI
  17. Oh, 2012, Lab Chip, 12, 515, 10.1039/C2LC20799K · DOI · Paper page
  18. Walker, 2007, Lab Chip, 7, 226, 10.1039/B608990A · DOI
  19. Lee, 2009, Lab Chip, 9, 709, 10.1039/B813582G · DOI
  20. Jeon, 2000, Langmuir, 16, 8311, 10.1021/la000600b · DOI · Paper page
  21. Hung, 2005, Biotechnol. Bioeng., 89, 1, 10.1002/bit.20289 · DOI · Paper page
  22. Kim, 2011, Lab Chip, 11, 874, 10.1039/c0lc00516a · DOI
  23. Moya, 2013, Tissue Eng., Part C, 10.1089/ten.TEC.2012.0430 · DOI · Paper page
  24. Griffith, 2005, Tissue Eng., 11, 257, 10.1089/ten.2005.11.257 · DOI · Paper page
  25. Cox, 1986, J. Polym. Sci., Part A: Polym. Chem., 24, 621, 10.1002/pola.1986.080240405 · DOI
  26. Cho, 2007, J. Colloid Interface Sci., 306, 379, 10.1016/j.jcis.2006.10.077 · DOI · Paper page
  27. Chen, 2010, Tissue Eng. A, 16, 585, 10.1089/ten.tea.2009.0491 · DOI · Paper page
  28. Kamei, 2006, Nature, 442, 453, 10.1038/nature04923 · DOI · Paper page

Cited by

Metadata

Authors
Hsu, Y.-H., Moya, M. L., Hughes, C. C. W., George, S. C., & Lee, A. P.
Venue
Lab on a Chip
Published
2013
Volume
13
Issue
15
Pages
2990
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2024343337
Cited by
192
References
0
FWCI
7.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.