The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Cell culture monitoring for drug screening and cancer research: a transparent, microfluidic, multi-sensor microsystem
Open accessAbstract
We present a novel, multiparametric microphysiometry system for the dynamic online monitoring of human cancer cell metabolism. The optically transparent, modular, hybrid microsystem is based on a glass chip and combines a cell cultivation chamber, microfluidics and metabolic monitoring with fully integrated chemo- and biosensors. pH and oxygen are measured in the cell culture area, and biosensors for lactate and glucose are connected downstream by microfluidics. The wafer-level fabrication features thin-film platinum and iridium oxide microelectrodes on a glass chip, microfluidics in an epoxy resist, a hybrid assembly and an on-chip reference electrode. The reliable analytical performance of the sensors in cell culture medium was demonstrated. The pH sensors exhibit a long-term stable, linear response. The oxygen sensors show a linear behaviour, which is also observed for low oxygen concentrations. Glucose and lactate measurements show a linear, long-term stable, selective and reversible behaviour in the desired range. T98G human brain cancer cells were cultivated and cell culture metabolism was measured on-chip. Stop/flow cycles were applied and extracellular acidification, respiration, glucose consumption and lactate production were quantified. Long-term metabolic rates were determined and all parameters could be measured in the outlet channel. A placement downstream of the cell cultivation area for biosensors was realised. A highly effective medium exchange and undiluted sampling from the cell culture chamber with low flow rates (2 μl min(-1)) and low volumes (15 μl per cycle) were achieved. The drug screening application was demonstrated by detecting alteration and recovery effects of cellular metabolism induced by the addition of substances to the medium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Proceedings of IEEE Sensors 2004
(2004) · Proceedings of IEEE Sensors, 2004. · doi:10.1109/icsens.2004.1426074 · Cited by 430
Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures
Ehret, R., Baumann, W., Brischwein, M., Schwinde, A., Stegbauer, K., & Wolf, B. (1997) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)89087-7 · Cited by 387
Self-citationStein, G. H. (1979) · Journal of Cellular Physiology · doi:10.1002/jcp.1040990107 · Cited by 313
Yamanaka, K. (1989) · Japanese Journal of Applied Physics · doi:10.1143/jjap.28.632 · Cited by 280
Owicki, J. C., & Wallace Parce, J. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87004-9 · Cited by 273
Ebbesen, P., Pettersen, E. O., Gorr, T. A., Jobst, G., Williams, K., Kieninger, J., Wenger, R. H., Pastorekova, S., Dubois, L., Lambin, P., et al. (2009) · Journal of Enzyme Inhibition and Medicinal Chemistry · doi:10.1080/14756360902784425 · Cited by 218
Self-citationBiosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine
Moser, I. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00298-6 · Cited by 181
Self-citationCytosensor® Microphysiometer: technology and recent applications
Hafner, F. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00069-5 · Cited by 178
Simultaneous measurement of cellular respiration and acidification with a single CMOS ISFET
Lehmann, M., Baumann, W., Brischwein, M., Gahle, H.-J., Freund, I., Ehret, R., Drechsler, S., Palzer, H., Kleintges, M., Sieben, U., et al. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00123-3 · Cited by 137
Self-citation
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Zhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Cell-based biosensors: Recent trends, challenges and future perspectives
Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., & Malhotra, B. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111435 · Cited by 318
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
Organs-on-a-chip: a new tool for drug discovery
Polini, A., Prodanov, L., Bhise, N. S., Manoharan, V., Dokmeci, M. R., & Khademhosseini, A. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2014.886562 · Cited by 223
Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Liebisch, F., Weltin, A., Marzioch, J., Urban, G. A., & Kieninger, J. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128652 · Cited by 53
Self-citationToward improved in vitro models of human cancer
Ayuso, J. M., Park, K.-Y., Virumbrales-Muñoz, M., & Beebe, D. J. (2021) · APL Bioengineering · doi:10.1063/5.0026857 · Cited by 40
Microfluidic Systems for Neural Cell Studies
Babaliari, E., Ranella, A., & Stratakis, E. (2023) · Bioengineering · doi:10.3390/bioengineering10080902 · Cited by 13
Metadata
- Authors
- Weltin, A., Slotwinski, K., Kieninger, J., Moser, I., Jobst, G., Wego, M., Ehret, R., & Urban, G. A.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 1
- Pages
- 138-146
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2002127906
- Cited by
- 263
- References
- 20
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.