The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Quantification of cortisol in human eccrine sweat by liquid chromatography – tandem mass spectrometry
Open accessAbstract
Cortisol was separated from its isomers and quantified by HPLC-MS/MS in human eccrine sweat samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Cortisol is responsible for maintaining homeostasis in the body via the regulation of neural, immune, cardiovascular, metabolic, and endocrine systems.102”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [102]
In the citing paper
“Cortisol is a steroid hormone secreted from the adrenal glands in response to stress as a product in the hypothalamic–pituitary adrenal pathway.102”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [102]
In the citing paper
“The study detected one isomer that had a similar hydrophobicity, retention time, and fragmentation patterns to that of cortisol found in eccrine sweat.”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [102]
In the citing paper
“Prior work to measure stress-related biomarkers has utilized high-performance liquid chromatography (HPLC),99 enzyme-linked immunosorbent assay,100 radioimmunoassay kit,101 or a HPLC mass spectrometry (MS) system.102”
From Wearable sensors for monitoring the physiological and biochemical profile of the athlete (2019) · cites this paper as [102]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,426
Silverman, M. N., & Sternberg, E. M. (2012) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2012.06633.x · Cited by 775
Self-citationExercise and circulating cortisol levels: the intensity threshold effect
Hill, E. E., Zack, E., Battaglini, C., Viru, M., Viru, A., & Hackney, A. C. (2008) · Journal of Endocrinological Investigation · doi:10.1007/bf03345606 · Cited by 666
Krone, N., Hughes, B. A., Lavery, G. G., Stewart, P. M., Arlt, W., & Shackleton, C. H. L. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.04.010 · Cited by 434
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373
A short history of sweat gland biology
Wilke, K., Martin, A. E., Terstegen, L., & Biel, S. S. (2007) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.2007.00387.x · Cited by 333
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
Adverse Consequences of Glucocorticoid Medication: Psychological, Cognitive, and Behavioral Effects
Judd, L. L., Schettler, P. J., Brown, E. S., Wolkowitz, O. M., Sternberg, E. M., Bender, B. G., Bulloch, K., Cidlowski, J. A., de Kloet, E. R., Fardet, L., et al. (2014) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2014.13091264 · Cited by 238
Self-citationDetermination of cortisol in serum, saliva and urine
Turpeinen, U., & Hämäläinen, E. (2013) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2013.10.008 · Cited by 214
Clinical applications of cortisol measurements in hair
Wester, V. L., & van Rossum, E. F. C. (2015) · European Journal of Endocrinology · doi:10.1530/eje-15-0313 · Cited by 210
Research works printed but not linked: 1
- Yamaguchi, 2014, Sens. Biosens. Res., 1, 15
Cited by
Sorted by citations
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring
Wang, B., Zhao, C., Wang, Z., Yang, K.-A., Cheng, X., Liu, W., Yu, W., Lin, S., Zhao, Y., Cheung, K. M., et al. (2022) · Science Advances · doi:10.1126/sciadv.abk0967 · Cited by 411
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Biomarkers in Stress Related Diseases/Disorders: Diagnostic, Prognostic, and Therapeutic Values
Dhama, K., Latheef, S. K., Dadar, M., Samad, H. A., Munjal, A. K., Khandia, R., Karthik, K., Tiwari, R., Yatoo, M. I., Bhatt, P., et al. (2019) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2019.00091 · Cited by 354
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Touch‐Based Stressless Cortisol Sensing
Tang, W., Yin, L., Sempionatto, J. R., Moon, J., Teymourian, H., & Wang, J. (2021) · Advanced Materials · doi:10.1002/adma.202008465 · Cited by 302
Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms
Brothers, M. C., DeBrosse, M., Grigsby, C. C., Naik, R. R., Hussain, S. M., Heikenfeld, J., & Kim, S. S. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00555 · Cited by 207
Laochai, T., Yukird, J., Promphet, N., Qin, J., Chailapakul, O., & Rodthongkum, N. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114039 · Cited by 160
Flexible molecularly imprinted electrochemical sensor for cortisol monitoring in sweat
Mugo, S. M., & Alberkant, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02430-0 · Cited by 139
Advances in Sweat Wearables: Sample Extraction, Real-Time Biosensing, and Flexible Platforms
Qiao, L., Benzigar, M. R., Subramony, J. A., Lovell, N. H., & Liu, G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c07614 · Cited by 140
Stress Monitoring and Recent Advancements in Wearable Biosensors
Samson, C., & Koh, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01037 · Cited by 129
Recent Advances in Electrochemical Sensors for Wearable Sweat Monitoring: A Review
Yeung, K. K., Huang, T., Hua, Y., Zhang, K., Yuen, M. M. F., & Gao, Z. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3074311 · Cited by 131
Sweat and saliva cortisol response to stress and nutrition factors
Pearlmutter, P., Derose, G., Samson, C., Linehan, N., Cen, Y., Begdache, L., Won, D., & Koh, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-75871-3 · Cited by 128
Electrochemical sensors for cortisol detections: Almost there
Zea, M., Bellagambi, F. G., Halima, H. B., Zine, N., Jaffrezic-Renault, N. J., Villa, R., Gabriel, G., & Errachid, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116058 · Cited by 122
Hybrid Integration of Wearable Devices for Physiological Monitoring
Zhang, Y., Zheng, X. T., Zhang, X., Pan, J., & Thean, A. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00471 · Cited by 126
Zamkah, A., Hui, T., Andrews, S., Dey, N., Shi, F., & Sherratt, R. S. (2020) · Biosensors · doi:10.3390/bios10040040 · Cited by 110
Molecularly imprinted polymers in diagnostics: accessing analytes in biofluids
Mustafa, Y. L., Keirouz, A., & Leese, H. S. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb00703g · Cited by 109
Review of Stress Detection Methods Using Wearable Sensors
Taskasaplidis, G. V., Fotiadis, D. A., & Bamidis, P. D. (2024) · IEEE Access · doi:10.1109/access.2024.3373010 · Cited by 131
Gomes, H. C., Liu, X., Fernandes, A. J. S., Moreirinha, C., Singh, R., Kumar, S., Costa, F. M., Santos, N. F., & Marques, C. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100186 · Cited by 108
Ganguly, A., Lin, K., Muthukumar, S., & Prasad, S. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01754 · Cited by 110
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103
Antibody-Coated Wearable Organic Electrochemical Transistors for Cortisol Detection in Human Sweat
Demuru, S., Kim, J., Chazli, M. E., Bruce, S., Dupertuis, M., Binz, P., Saubade, M., Lafaye, C., & Briand, D. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01250 · Cited by 95
Technological Advances of Wearable Device for Continuous Monitoring of In Vivo Glucose
Huang, X., Yao, C., Huang, S., Zheng, S., Liu, Z., Liu, J., Wang, J., Chen, H., & Xie, X. (2024) · ACS Sensors · doi:10.1021/acssensors.3c01947 · Cited by 84
Assalve, G., Lunetti, P., di Cagno, A., Luca, E. W. D., Aldegheri, S., Zara, V., & Ferramosca, A. (2024) · Biosensors · doi:10.3390/bios14120574 · Cited by 86
(2017) · PubMed Central · Cited by 76
Francis, J., Stamper, I., Heikenfeld, J. C., & Gomez, E. F. (2018) · Lab on a Chip · doi:10.1039/c8lc00968f · Cited by 67
Pérez, D., & Orozco, J. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05228-2 · Cited by 67
Yokus, M. A., & Daniele, M. A.-A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113249 · Cited by 62
The Use of Wearable Technology in Providing Assistive Solutions for Mental Well-Being
Alhejaili, R. A., & Alomainy, A. (2023) · Sensors · doi:10.3390/s23177378 · Cited by 63
Halicka, K., Meloni, F., Czok, M. J., Spychalska, K., Baluta, S., Malecha, K., Pilo, M. I., & Cabaj, J. (2022) · ACS Omega · doi:10.1021/acsomega.2c04134 · Cited by 54
Mugo, S. M., Lu, W., & Robertson, S. V. (2022) · Biosensors · doi:10.3390/bios12100854 · Cited by 52
Progress in nanoparticle-based electrochemical biosensors for hormone detection
Rossi, F., Trakoolwilaiwan, T., Gigli, V., Tortolini, C., Lenzi, A., Isidori, A. M., Thanh, N. T. K., & Antiochia, R. (2024) · Nanoscale · doi:10.1039/d4nr02075h · Cited by 51
Direct Surface Enhanced Raman Spectroscopic Detection of Cortisol at Physiological Concentrations
Moore, T. J., & Sharma, B. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04532 · Cited by 50
Yuan, X., Ouaskioud, O., Yin, X., Li, C., Ma, P., Yang, Y., Yang, P., Xie, L., & Ren, L. M. (2023) · Micromachines · doi:10.3390/mi14071452 · Cited by 52
Kim, H. T., Jin, E., & Lee, M. (2021) · Biosensors · doi:10.3390/bios11060191 · Cited by 49
Yang, J. L., Liu, H., Huang, Y., Li, L., Zhu, X., & Yaping, D. (2023) · Talanta · doi:10.1016/j.talanta.2023.124637 · Cited by 47
Jeon, J., Uthaman, S., Lee, J., Hwang, H., Kim, G. B., Yoo, P. J., Hammock, B. D., Kim, C. S. K., Park, Y.-S., & Park, I. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.03.167 · Cited by 47
Brazaca, L. C., Imamura, A. H., Blasques, R. V., Camargo, J. R., Janegitz, B. C., & Carrilho, E. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115846 · Cited by 46
Tang, M., Shi, Y., Jiang, X., Xu, H., Ma, Y., & Zhao, B. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc01342d · Cited by 42
Gut feelings about bacterial steroid-17,20-desmolase
Ly, L. K., Doden, H. L., & Ridlon, J. M. (2021) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2021.111174 · Cited by 45
Wearable microneedle dual electrochemical sensor for simultaneous pH and cortisol detection in sweat
Mugo, S. M., Lu, W., Wood, M., & Lemieux, S. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100039 · Cited by 40
Autonomous wearable sensing enabled by capillary microfluidics: a review
Kuruvinashetti, K., Komeili, A., & Sanati‐Nezhad, A. (2025) · Lab on a Chip · doi:10.1039/d5lc00536a · Cited by 44
Cinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 36
Hossain, N. I., Noushin, T., & Tabassum, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-81042-5 · Cited by 39
Advances in wearable electrochemical antibody-based sensors for cortisol sensing
Khumngern, S., & Jeerapan, I. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04577-y · Cited by 39
Recent advances in aptamer-based platforms for cortisol hormone monitoring
Mohammadi, F., Zahraee, H., Kazemi, M., Habibi, Z. S., Taghdisi, S. M., Abnous, K., Khoshbin, Z., & Chen, C. (2023) · Talanta · doi:10.1016/j.talanta.2023.125010 · Cited by 35
Conceptualizing the Vertebrate Sterolbiome
Ridlon, J. M. (2020) · Applied and Environmental Microbiology · doi:10.1128/aem.00641-20 · Cited by 35
Screening of Potential Stress Biomarkers in Sweat Associated with Sports Training
Nunes, M. J., Cordas, C. M., Moura, J. J. G., Noronha, J. P., & Branco, L. C. (2021) · Sports Medicine - Open · doi:10.1186/s40798-020-00294-3 · Cited by 38
Brunmair, J., Bileck, A., Stimpfl, T., Raible, F., Favero, G. D., Meier, S. M., & Gerner, C. (2021) · The EPMA Journal · doi:10.1007/s13167-021-00241-6 · Cited by 27
Moghadam, F. M., Bigdeli, M. R., Tamayol, A., & Shin, S. R. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130160 · Cited by 27
Recent Advances in Self‐Powered Electrochemical Biosensors for Early Diagnosis of Diseases
Galstyan, V., D’Onofrio, I., Liboà, A., Giorgio, G. D., Vurro, D., Rovati, L. L., Tarabella, G., & D’Angelo, P. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400395 · Cited by 27
Sweat analysis for urea sensing: trends and challenges
Futane, A., Senthil, M., Jayashree, S., Srinivasan, A., Kalpana, R., & Narayanamurthy, V. (2023) · Analytical Methods · doi:10.1039/d3ay01089a · Cited by 28
Rind, S., Zhang, N., Khan, W. U., & Zhang, Q. M. (2025) · Wearable electronics. · doi:10.1016/j.wees.2025.08.002 · Cited by 28
Clinical translation of biomedical sensors for sports medicine
Seshadri, D. R., Magliato, S. N., Voos, J. E., & Drummond, C. K. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1612474 · Cited by 21
Sweat-Based in Vitro Diagnostics (IVD): From Sample Collection to Point-of-Care Testing (POCT)
Sarwar, M., Rodriguez, P., & Li, C.-Z. (2019) · Journal of Analysis and Testing · doi:10.1007/s41664-019-00097-w · Cited by 19
Ma, J., Li, H., Anwer, S., Umer, W., Antwi‐Afari, M. F., & Xiao, E. B. (2024) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2024.2330242 · Cited by 20
Preparation of a magnetic molecularly imprinted polymer for non-invasive determination of cortisol
Villa, J. E. L., Khan, S., Neres, L. C. S., & Sotomayor, M. D. P. T. (2021) · Journal of Polymer Research · doi:10.1007/s10965-021-02659-y · Cited by 17
Biomarcadores en la medición del estrés: una revisión sistemática
Morera, L. P., Tempesti, T. C., Pérez, E., & Medrano, L. A. (2019) · Ansiedad y Estrés · doi:10.1016/j.anyes.2019.02.001 · Cited by 34
Pei, S., Ji, W., Yang, Y. F., Liu, T., Yang, S., Wu, J., Dai, J., Hou, X., Wu, Q., & Li, L. (2024) · Analysis & Sensing · doi:10.1002/anse.202400003 · Cited by 17
Perspective—Electrochemical Bio-wearables for Cortisol Monitoring
Pandey, R. (2024) · ECS Sensors Plus · doi:10.1149/2754-2726/ad408e · Cited by 15
King, M. A., Brown, S. D., Barnes, K. A., Chavez, P. J. D. D., & Baker, L. B. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05187-3 · Cited by 16
Choi, C. W., Hong, D., & Kim, M. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116971 · Cited by 14
Aydin, E., Drotleff, B., Noack, H., Derntl, B., & Lämmerhofer, M. (2021) · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · doi:10.1016/j.jchromb.2021.122939 · Cited by 12
van Aalen, E. A., Lurvink, J. J. J., Vermeulen, L., van Gerven, B., Ni, Y., Arts, R., & Merkx, M. (2024) · ACS Sensors · doi:10.1021/acssensors.3c02478 · Cited by 13
An Immunosensor for the Determination of Cortisol in Serum and Saliva by Array SPRi
Sankiewicz, A., Ołdak, Ł., Żelazowska‐Rutkowska, B., Hermanowicz, A., Łukaszewski, Z., & Gorodkiewicz, E. (2022) · Sensors · doi:10.3390/s22249675 · Cited by 12
Karaman, C., Aydemir, M., & Karaman, O. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118687 · Cited by 11
A Gold Nanoparticle-Based Cortisol Aptasensor for Non-Invasive Detection of Fish Stress
Tanaka, Y., Salleh, N. A. B. M., Tan, M. R., Vij, S., Wee, C. L., Sutarlie, L., & Su, X. (2024) · Biomolecules · doi:10.3390/biom14070818 · Cited by 9
Myochin, H., Ohshima, N., Izumi, T., Hisajima, T., Chaleckis, R., & Mori, M. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.464769 · Cited by 9
Luo, D., Liu, B., Gao, R., Su, L., & Su, Y. (2022) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-021-05101-x · Cited by 9
Glycated hemoglobin (HbA1c) and biofluid-based diagnosis in diabetes: A comprehensive review
Chowdhury, J. R., Peringeth, K., Ganguly, A., Necesario, S. R. S., Hsieh, W., Ra, Y., Choi, D., & Lin, Z. (2024) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2024.118301 · Cited by 8
A Metabolomic Approach for Predicting Diurnal Changes in Cortisol
Eshima, J., Davis, T. J., Bean, H. D., Fricks, J., & Smith, B. S. (2020) · Metabolites · doi:10.3390/metabo10050194 · Cited by 7
Wang, B., Wilhelm, A., Wilhelm, A., Pilehvar, S., Moshfeghi, S., Stout, P., Salahi, K., & Emaminejad, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102407-2.00003-5 · Cited by 6
Dynamic Behavior of Cortisol and Cortisol Metabolites in Human Eccrine Sweat
Runyon, J. R., Jia, M., Goldstein, M. R., Skeath, P. R., Abrell, L. M., Chorover, J., & STERNBERG, E. M. (2023) · International Journal of Prognostics and Health Management · doi:10.36001/ijphm.2019.v10i3.2707 · Cited by 5
Self-citationAshton, R., Rizwan, M., & Gwenin, C. D. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100325 · Cited by 4
Alvi, S. N., Abuhdeeb, K., & Hammami, M. M. (2022) · Advances in Pharmacological and Pharmaceutical Sciences · doi:10.1155/2022/3133640 · Cited by 4
Development and application of microfluidic sweat detection technology in mental health monitoring
Zhao, D., Chen, R., Jiang, S., Xie, W., Zhang, K., Zhao, J., Feng, S., & Bian, S. (2025) · Open Research (University of Surrey) · doi:10.1002/viw.20240088 · Cited by 4
Biosensor platforms for biomarker detection: plasmonic aptasensors for detection of Neuropeptide Y
Chávez, J. L., Rieger, K., Hagen, J. A., & Kelley‐Loughnane, N. (2019) · Smart Biomedical and Physiological Sensor Technology · doi:10.1117/12.2520330 · Cited by 4
Low-molecular-weight biomarkers: types and detection strategies
Mollarasouli, F., & Bahrani, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822859-3.00012-2 · Cited by 5
Harris, J., Bickford, J. R., Cho, P. S., Coppock, M. B., Farrell, M. E., Holthoff, E. L., & Ratcliff, E. L. (2019) · Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing · doi:10.1117/12.2518543 · Cited by 4
Screen-Printed Electrodes Testing for Detection of Potential Stress Biomarkers in Sweat
Nunes, M. J., Valério, G. N., Samhan-Arias, A. K., Moura, J. J. G., Rouco, C., Sousa, J. P., & Cordas, C. M. (2022) · Electrocatalysis · doi:10.1007/s12678-022-00709-7 · Cited by 4
A Method for Assessing Week-Long Cortisol Output Using a Continuously Worn Sweat Patch
Meyer, J. S., Blain, J. P., & Kalmakis, K. A. (2026) · Methods and Protocols · doi:10.3390/mps9010013 · Cited by 3
An Electrochemical Cortisol Sensor Based on rGO-Modified Molecularly Imprinted Polymers
Liu, Z., Xie, G., Li, J., & Su, Y. (2026) · Journal of Composites Science · doi:10.3390/jcs10020096 · Cited by 3
Ramos-Reyes, G. M., Corona‐Avendaño, S., Ramírez-Silva, M. T., Romero-Romo, M., & Palomar-Pardavé, M. (2024) · Journal of Applied Spectroscopy · doi:10.1007/s10812-024-01709-9 · Cited by 3
Merritt, J. R., Ozga, M., Chavez, P. J. D. D., Boolani, A., & Baker, L. B. (2024) · Scientific Reports · doi:10.1038/s41598-024-63057-0 · Cited by 3
Hormonal control of amphibian reproduction
Trudeau, V. L., Raven, B. H., Pahuja, H., & Narayan, E. J. (2022) · CSIRO Publishing eBooks · doi:10.1071/9781486313341.bk07961_ch04 · Cited by 3
LCMS Measurement of Steroid Biomarkers Collected from Palmar Sweat.Preprint
Hyde, J., & Runyon, J. R. (2020) · ChemRxiv · doi:10.26434/chemrxiv.12931769 · Cited by 3
Vajhadin, F., Kuruvinashetti, K., Zare, A., Hassani, M., Khalghollah, M., Abdollahi, S., Rosenegger, D. G., Komeili, A., & Sanati‐Nezhad, A. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.174373 · Cited by 2
Uruc, S., Gorduk, O., Gördük, S., & Şahin, Y. (2026) · Diamond and Related Materials · doi:10.1016/j.diamond.2026.113628 · Cited by 2
Cortisol as a stress biomarker: analytical perspectives and challenges
Suryawanshi, R., & Sharma, S. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121008 · Cited by 2
Ott, M., Singh, N., Bauland, F., Köppl, D., Kandler, K., Gaudl, A., Geistanger, A., Ceglarek, U., Rauh, M., Geletneky, C., et al. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0879 · Cited by 2
Molecular basis of signal transduction in a cortisol-binding aptamer
Arachchige, L. J., & Walsh, T. R. (2026) · Physical Chemistry Chemical Physics · doi:10.1039/d5cp04384k · Cited by 1
Effects of head impact exposure on in-game heart rate dynamics in Canadian varsity football athletes
Zafar, A., Martens, G., Guay, S., Vinet, S.-A., Wagnac, É., Corbin‐Berrigan, L., Prince, F., Pantazis, J. T., Prince, S., & Beaumont, L. D. (2026) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2026.05.001 · Cited by 1
Wearable and implantable aptamer sensors for physiological monitoring
Lee, H. B., Lee, D., & Ko, S. H. (2026) · Soft Science · doi:10.20517/ss.2025.149 · Cited by 1
Sweat as a Testing Analytical Fluid for Emotions and Stress Biomarkers Detection
Cordas, C. M., Nunes, M. J., Valério, G. N., Samhan-Arias, A. K., Krippahl, L., Moura, J. J. G., Santos, G., Sousa, J. P., & Rouco, C. (2023) · Smart innovation, systems and technologies · doi:10.1007/978-981-19-7689-6_7 · Cited by 1
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 1
Borràs, N., Jiménez, M. S., Casanovas, J., Alemán, C., & Pérez‐Madrigal, M. M. (2022) · Macromolecular Materials and Engineering · doi:10.1002/mame.202200269 · Cited by 1
LCMS Measurement of Steroid Biomarkers Collected from Palmar Sweat.Preprint
Hyde, J., & Runyon, J. R. (2020) · ChemRxiv · doi:10.26434/chemrxiv.12931769.v1
Metadata
- Authors
- Jia, M., Chew, W. M., Feinstein, Y., Skeath, P., & Sternberg, E. M.
- Affiliations
- University of Arizona (US)
- Corresponding author
- Jia, Min
- Sternberg, Esther M.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 141
- Issue
- 6
- Pages
- 2053-2060
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- PMC
- PMC5376102
- OpenAlex
- W2260554414
- Cited by
- 113
- References
- 32
- Citations by year
- 2026: 16 · 2025: 6 · 2024: 22 · 2023: 11 · 2022: 14 · 2021: 15 · 2020: 14 · 2019: 11 · 2018: 3 · 2017: 1
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- The Analyst (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Air Force Research Laboratory (FA8650-13-2-7311)
- Topics
- Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- cortisol, eccrine sweat, sweat biomarkers, stress biomarkers, non-invasive stress assessment, steroid quantification, atmospheric pressure chemical ionization, multiple reaction monitoring
- MeSH terms
- Chromatography, High Pressure Liquid, Exocrine Glands, Humans, Hydrocortisone, Sweat, Time Factors, Reproducibility of Results, Clinical Chemistry Tests, Analytic Sample Preparation Methods, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review