CoChat

Exceptional CO 2 working capacity in a heterodiamine-grafted metal–organic framework

Open access

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Abstract

The amine functionalized material 1-dmen shows a record high working capacity for CO 2 capture at low regeneration temperatures compared with other MOFs. Furthermore, this performance is maintained upon exposure to humidity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c5sc01191d

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 (a) Synchrotron PXRD profiles of 1-dmen, 1-dmen-CO2 , and 1-dmen-re. (b) Enlargement of the low-angle region of the PXRD data. (c) Framework structure of 1 with open metal sites, grafting modes of dmen onto the open metal sites, and subsequent CO2 adsorption. The schematic diagram (bottom) indicates the arrangement of ammonium carbamates running along the c-axis.
Fig. 1 (a) Synchrotron PXRD profiles of 1-dmen, 1-dmen-CO2 , and 1-dmen-re. (b) Enlargement of the low-angle region of the PXRD data. (c) Framework structure of 1 with open metal sites, grafting modes of dmen onto the open metal sites, and subsequent CO2 adsorption. The schematic diagram (bottom) indicates the arrangement of ammonium carbamates running along the c-axis.CC BY-NC · PubMed Central
Fig. 2 (a) Adsorption isotherms of CO2 for 1-dmen at the indicated temperatures. The solid lines are eye-guides. (b) CO2 and N2 isotherms at 25 °C.
Fig. 2 (a) Adsorption isotherms of CO2 for 1-dmen at the indicated temperatures. The solid lines are eye-guides. (b) CO2 and N2 isotherms at 25 °C.CC BY-NC · PubMed Central
Fig. 3 (a) Adsorption–desorption cycling of CO2 for 1-dmen, showing reversible uptake from simulated flue gas (0.15 bar CO2 balanced with N2). Adsorption temperature was 40 °C and desorption temperatures were 130 °C, 60 °C, 50 °C, 40 °C, and 30 °C under Ar. (b) Adsorption–desorption cycling of CO2 at 40 °C by switching atmospheres between simulated flue gas and Ar. (c) Adsorption–desorption cycling of CO2 at adsorption (40 °C) and desorption (75 °C) under Ar. (d) Vacuum-swing adsorption at 25 °C using a Micromeritics ASAP2020 instrument.
Fig. 3 (a) Adsorption–desorption cycling of CO2 for 1-dmen, showing reversible uptake from simulated flue gas (0.15 bar CO2 balanced with N2). Adsorption temperature was 40 °C and desorption temperatures were 130 °C, 60 °C, 50 °C, 40 °C, and 30 °C under Ar. (b) Adsorption–desorption cycling of CO2 at 40 °C by switching atmospheres between simulated flue gas and Ar. (c) Adsorption–desorption cycling of CO2 at adsorption (40 °C) and desorption (75 °C) under Ar. (d) Vacuum-swing adsorption at 25 °C using a Micromeritics ASAP2020 instrument.CC BY-NC · PubMed Central
Fig. 4 (a) Adsorption–desorption cycling of CO2 for 1-dmen. The adsorption of simulated flue gas (0.15 bar CO2 balanced with N2) was recorded at 40 °C and desorption was performed at 130 °C under flowing pure CO2. The symbol C represents the influx of pure CO2 to regenerate the sample. The working capacity is determined as the difference between A and B. (b) The working capacities of 1-dmen and the other porous solids obtained under the same conditions. (c) CO2 adsorption of 1-dmen in flue gas using the sequence (adsorption at 40 °C – desorption at 130 °C under pure CO2 – 10 min exposure to 100% RH). (d) Working capacities of the CO2 uptake in the first and second cycles for 1-dmen, mmen-Mg2(dobpdc), en-Mg2(dobpdc), Mg2(dobpdc), and Mg–MOF-74 using TG experiments. The first cycle was measured with fully activated samples in flue gas, and the second cycle was measured by following the sequence.
Fig. 4 (a) Adsorption–desorption cycling of CO2 for 1-dmen. The adsorption of simulated flue gas (0.15 bar CO2 balanced with N2) was recorded at 40 °C and desorption was performed at 130 °C under flowing pure CO2. The symbol C represents the influx of pure CO2 to regenerate the sample. The working capacity is determined as the difference between A and B. (b) The working capacities of 1-dmen and the other porous solids obtained under the same conditions. (c) CO2 adsorption of 1-dmen in flue gas using the sequence (adsorption at 40 °C – desorption at 130 °C under pure CO2 – 10 min exposure to 100% RH). (d) Working capacities of the CO2 uptake in the first and second cycles for 1-dmen, mmen-Mg2(dobpdc), en-Mg2(dobpdc), Mg2(dobpdc), and Mg–MOF-74 using TG experiments. The first cycle was measured with fully activated samples in flue gas, and the second cycle was measured by following the sequence.CC BY-NC · PubMed Central
Fig. 5 (a) CO2 adsorption–desorption cycling curve for 1-dmen in humid conditions. (b) Breakthrough curves for 1-dmen under dry (N2, red circle; CO2, orange circle) and humid conditions (N2, green triangle; CO2, blue triangle).
Fig. 5 (a) CO2 adsorption–desorption cycling curve for 1-dmen in humid conditions. (b) Breakthrough curves for 1-dmen under dry (N2, red circle; CO2, orange circle) and humid conditions (N2, green triangle; CO2, blue triangle).CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Lu, 2013, Inorg. Chem., 109, 484

Cited by

See all 153

Metadata

Authors
Lee, W. R., Jo, H., Yang, L.-M., Lee, H., Ryu, D. W., Lim, K. S., Song, J. H., Min, D. Y., Han, S. S., Seo, J. G., Park, Y. K., Moon, D., & Hong, C. S.
Affiliations
  • Korea University (KR)
  • Korea Institute of Science and Technology (KR)
  • Myongji University (KR)
  • Korea Research Institute of Chemical Technology (KR)
  • Pohang Accelerator Laboratory (KR)
Corresponding author
Hong, Chang Seop
Venue
Chemical Science
Published
2015
Volume
6
Issue
7
Pages
3697-3705
ISSN
  • 2041-6520 (ISSN-L)
  • 2041-6539
OpenAlex
W2024575076
Cited by
153
References
53
Citations by year
2026: 6 · 2025: 13 · 2024: 10 · 2023: 10 · 2022: 14 · 2021: 15 · 2020: 20 · 2019: 14 · 2018: 20 · 2017: 15 · 2016: 14 · 2015: 2
FWCI
6.98
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Chemical Science (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
  • Korea University
  • Ministry of Science, ICT and Future Planning (NRF-2014M1A8A1049253)
  • Korea Institute of Science and Technology (2E24630)
  • Korea Carbon Capture and Sequestration R and D Center
Topics
  • Physical Sciences › Chemistry › Inorganic Chemistry › Metal-Organic Frameworks: Synthesis and Applications
  • Physical Sciences › Chemical Engineering › Filtration and Separation › Carbon Dioxide Capture Technologies
  • Physical Sciences › Materials Science › Materials Chemistry › Covalent Organic Framework Applications
Keywords
CO2 capture, metal-organic frameworks, amine-functionalized MOFs, work capacity, moisture resistance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.