The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Novel dual-function near-infrared II fluorescence and PET probe for tumor delineation and image-guided surgery
Open accessAbstract
The first small-molecule based αvβ 3-targeted NIR-II/PET dual-modal probes via base-catalyzed thiol-addition chemistry were concisely assembled and evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationMultimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Self-citationTraumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386
Self-citation
Cited by
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
Self-citationAdvanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
Self-citationRecent advances in near-infrared II fluorophores for multifunctional biomedical imaging
Ding, F., Zhan, Y., Lu, X., & Sun, Y. (2018) · Chemical Science · doi:10.1039/c8sc01153b · Cited by 538
Self-citationLiu, Y., Li, Y., Koo, S., Sun, Y., Liu, Y., Liu, X., Pan, Y., Zhang, Z., Du, M., Lu, S., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00553 · Cited by 537
Self-citation
Metadata
- Authors
- Sun, Y., Zeng, X., Xiao, Y., Liu, C., Zhu, H., Zhou, H., Chen, Z., Xu, F., Wang, J., Zhu, M., Wu, J., Tian, M., Zhang, H., Deng, Z., Cheng, Z., & Hong, X.
- Venue
- Chemical Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 9
- Issue
- 8
- Pages
- 2092-2097
- ISSN
- 2041-6520 (ISSN-L)
- 2041-6539
- OpenAlex
- W2781796433
- Cited by
- 161
- References
- 4
- FWCI
- 11.92
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel dual-function near-infrared II fluorescence and PET probe for tumor delineation and image-guided surgery. https://app.cochat.ai/papers/10.1039/c7sc04774f
- The paper
- Sun, Y., Zeng, X., Xiao, Y., Liu, C., Zhu, H., Zhou, H., Chen, Z., Xu, F., Wang, J., Zhu, M., Wu, J., Tian, M., Zhang, H., Deng, Z., Cheng, Z., & Hong, X. (2018). Novel dual-function near-infrared II fluorescence and PET probe for tumor delineation and image-guided surgery. Chemical Science. https://doi.org/10.1039/c7sc04774f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.