Measuring and regulating oxygen levels in microphysiological systems: design, material, and sensor considerations
Open accessThe DOI matches its Crossref record; 240 of the 240 references it cites were found in a registry or an index.
Abstract
Quantifying and regulating oxygen in a microphysiological models can be achieved via an array of technologies, and is an essential component of recapitulating tissue-specific microenvironments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Additionally, despite the existence of culture systems incorporating an oxygen gradient for other research purposes, none of the current systems are suitable for retinal organoid culture over extended periods of time because of the large size of organoids (up to 1000 μm), and extremely long culture times (several months).24”
From Retinal organoid chip: engineering a physiomimetic oxygen gradient for optimizing long term culture of human retinal organoids (2025) · cites this paper as [24]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Intestinal mucosal barrier function in health and disease
Turner, J. R. (2009) · Nature reviews. Immunology · doi:10.1038/nri2653 · Cited by 3,952
Pathobiology of ischaemic stroke: an integrated view
Dirnagl, U., Iadecola, C., & Moskowitz, M. A. (1999) · Trends in Neurosciences · doi:10.1016/s0166-2236(99)01401-0 · Cited by 3,943
Fridovich (1978) · doi:10.1126/science.210504 · Cited by 3,329
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Cell Biology of Ischemia/Reperfusion Injury
(2012) · International Review of Cell and Molecular Biology · doi:10.1016/b978-0-12-394309-5.00006-7 · Cited by 2,178
Drug Resistance and the Solid Tumor Microenvironment
Tredan, O., Galmarini, C. M., Patel, K., & Tannock, I. F. (2007) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djm135 · Cited by 2,116
Research works printed but not linked: 8
- Merkel TC, Bondar VI, Nagai K, Freeman BD and Pinnau I, J Polym Sci Pol Phys, 2000, 38, 415– 434. · DOI · Paper page
- Shuk P and Jantz R, 2015 9th International Conference on Sensing Technology (Icst), 2015, 12– 17.
- Hauser CJ, Locke RR, Kao HW, Patterson J and Zipser RD, J Lab Clin Med, 1988, 112, 68– 71. 3392458
- Park J, Youngmi KP, James JP, Sensors and Actuators B: Chemical, 2010, 147, 263– 269. · DOI
- Kieninger J, Dannenberg A, Aravindalochanan K, Jobst G, Pettersen EO and Urban GA, Transducers ‘07 & Eurosensors Xxi, Digest of Technical Papers, Vols 1 and 2, 2007.
- Sin A, Chin KC, Jamil MF, Kostov Y, Rao G and Shuler ML, Biotechnol Prog, 2004, 20, 338– 345. 14763861 · DOI · Paper page
- Nourmohammadzadeh M, Lo JF, Bochenek M, Mendoza-Elias JE, Wang Q, Li Z, Zeng L, Qi M, Eddington DT, Oberholzer J and Wang Y, Anal Chem, 2013, 85, 11240– 11249. 24083835 PMC3921903 · DOI
- Gitlin L, Hoera C, Meier RJ, Nagl S and Belder D, Lab Chip, 2013, 13, 4134– 4141. 23970303 · DOI
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Fuchs, S., Johansson, S., Tjell, A. Ø., Werr, G., Mayr, T., & Tenje, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01110 · Cited by 213
A Comprehensive Review of Organ-on-a-Chip Technology and Its Applications
Doost, N. F., & Srivastava, S. K. (2024) · Biosensors · doi:10.3390/bios14050225 · Cited by 187
“A thorough study of in situ dissolved oxygen measurements in OOC was conducted by Rivera et al. [65].”
MethodJoint-on-chip platforms: entering a new era of in vitro models for arthritis
Paggi, C. A., Teixeira, L. M., Gac, S. L., & Karperien, M. (2022) · Nature Reviews Rheumatology · doi:10.1038/s41584-021-00736-6 · Cited by 100
Stem Cells for Next Level Toxicity Testing in the 21st Century
Fritsche, E., Haarmann‐Stemmann, T., Kapr, J., Galanjuk, S., Hartmann, J., Mertens, P. R., Kämpfer, A. A. M., Schins, R. P. F., Tigges, J., & Koch, K. (2021) · Small · doi:10.1002/smll.202006252 · Cited by 75
Type 1 Diabetes Mellitus: A Review on Advances and Challenges in Creating Insulin Producing Devices
Oliveira, S. M. R., Rebocho, A., Ahmadpour, E., Nissapatorn, V., & Pereira, M. D. L. (2023) · Micromachines · doi:10.3390/mi14010151 · Cited by 103
“Some trapping mechanisms used in islet immobilization are dam wall-like or nozzle-like traps [93,94].”
BackgroundOxygen control: the often overlooked but essential piece to create better in vitro systems
Palacio-Castañeda, V., Velthuijs, N., Gac, S. L., & Verdurmen, W. P. R. (2022) · Lab on a Chip · doi:10.1039/d1lc00603g · Cited by 62
Simitian, G. S., Virumbrales-Muñoz, M., Sánchez‐de‐Diego, C., Beebe, D. J., & Kosoff, D. (2022) · Lab on a Chip · doi:10.1039/d2lc00352j · Cited by 56
Metabolic Switching of Tumor Cells under Hypoxic Conditions in a Tumor-on-a-chip Model
Palacio-Castañeda, V., Kooijman, L. J., Venzac, B., Verdurmen, W. P. R., & Gac, S. L. (2020) · Micromachines · doi:10.3390/mi11040382 · Cited by 55
“A variety of platforms have been reported to address this significant limitation of PDMS and to apply well-defined oxygen tension or to create oxygen gradients across cell cultures, as recently reviewed [26,27].”
BackgroundTechnological tools and strategies for culturing human gut microbiota in engineered in vitro models
Sardelli, L., Perottoni, S., Tunesi, M., Boeri, L., Fusco, F., Petrini, P., Albani, D., & Giordano, C. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27816 · Cited by 43
“The modulation of the advection/diffusion ratio is necessary to control and enhance oxygen diffusion for stable and tailored oxygen tension profiles, which can be controlled by acting on the flow velocity along the principal channel direction (Rivera et al., 2019): Microfabrication techniques (e.”
BackgroundZhang, Y., Yu, T., Ding, J., & Li, Z. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114798 · Cited by 45
Insight into Hypoxia Stemness Control
Mattia, M. D., Mauro, A., Citeroni, M. R., Dufrusine, B., Peserico, A., Russo, V., Berardinelli, P., Dainese, E., Cimini, A., & Barboni, B. (2021) · Cells · doi:10.3390/cells10082161 · Cited by 45
“Given the difficulties in controlling O2 levels, appropriate O2 sensors should be applied in cell cultures to measure O2 concentration thus monitoring its fluctuations, however, they are not routinely used [62].”
BackgroundSaglam‐Metiner, P., Yıldırım, E., Dincer, C., Başak, O., & Yeşil-Çeliktaş, Ö. (2024) · Microchimica Acta · doi:10.1007/s00604-023-06165-4 · Cited by 41
“Measuring oxygen concentration is crucial for OoC platforms to recapitulate the physiological tissue [122].”
Perottoni, S., Neto, N. G. B., Nitto, C. D., Dmitriev, R. I., Raimondi, M. T., & Monaghan, M. G. (2021) · Lab on a Chip · doi:10.1039/d0lc01034k · Cited by 37
Organs‐on‐Chips: Trends and Challenges in Advanced Systems Integration
Mughal, S., López‐Muñoz, G. A., Fernández‐Costa, J. M., Cortés-Reséndiz, A., Chiara, F. D., & Ramón‐Azcón, J. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202201618 · Cited by 30
Drabbe, E., Pelaez, D., & Agarwal, A. (2025) · Lab on a Chip · doi:10.1039/d4lc00771a · Cited by 26
Mkilima, T. (2025) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.15352 · Cited by 35
“90 This precise control is essential for studying the impact of environmental factors on community composition, function,andinterspeciesinteractions,aswellasforoptimizinggrowth conditions to maximize the production of desired metabolites or biomass.”
Vaneev, A. N., Timoshenko, R. V., Gorelkin, P. V., Klyachko, N. L., Korchev, Y. E., & Erofeev, A. S. (2022) · Nanomaterials · doi:10.3390/nano12213736 · Cited by 24
“The most common bioanalytes are neurotransmitters [14,15], ascorbate [12], reactive oxygen and nitrogen species (ROS/RNS) [16], oxygen [17], and different metal ions [18] (Figure 1).”
BackgroundOxygen Measurement in Microdevices
Grist, S. M., Bennewith, K. L., & Cheung, K. C. (2022) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061020-111458 · Cited by 20
Precise and fast control of the dissolved oxygen level for tumor-on-chip
Bouquerel, C., César, W., Barthod, L., Arrak, S., Battistella, A., Gropplero, G., Mechta‐Grigoriou, F., Zalcman, G., Parrini, M. C., Verhulsel, M., et al. (2022) · Lab on a Chip · doi:10.1039/d2lc00696k · Cited by 22
Building blocks of microphysiological system to model physiology and pathophysiology of human heart
Vuorenpää, H., Björninen, M., Välimäki, H., Ahola, A., Kroon, M., Honkamäki, L., Koivumäki, J. T., & Pekkanen-Mattila, M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1213959 · Cited by 24
“Comprehensive reviews on current methodologies for oxygen measurement and control in MPS systems have recently been composed by Rivera and co-workers (Rivera et al., 2019) and earlier by Oomen et al (Oomen et al.”
MethodMahfouzi, S. H., Amoabediny, G., & Tali, S. H. S. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27728 · Cited by 19
“Therefore, a bioreactor should be able to measure biological para- meters such as pH, oxygen levels, CO2 levels, glucose consumption, and lactate production of the cells, preferably in real‐time and noninvasively (Al‐Ani et al., 2018; Rivera et al., 2019).”
BackgroundOrgan-on-Chip Technology for Aerobic Intestinal Host – Anaerobic Microbiota Research
Bossink, E. G. B. M., Segerink, L. I., & Odijk, M. (2021) · Organs-on-a-Chip · doi:10.1016/j.ooc.2021.100013 · Cited by 18
Automated electrochemical oxygen sensing using a 3D-printed microfluidic lab-on-a-chip system
Kaufman, D., Winkler, S., Heuer, C., Shibli, A., Snezhko, A., Livshits, G. I., Bahnemann, J., & Ben‐Yoav, H. (2024) · Lab on a Chip · doi:10.1039/d4lc00962b · Cited by 19
Organ-on-a-chip models for elucidating the cellular biology of infectious diseases
Yokoi, F., Deguchi, S., & Takayama, K. (2023) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2023.119504 · Cited by 21
Real-Time Monitoring of Oxygen Levels within Thermoplastic Organ-on-Chip Devices
Bussooa, A., Tubbs, E., Revol-Cavalier, F., Chmayssem, A., Alessio, M., Cosnier, M.-L., & Verplanck, N. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100198 · Cited by 31
O2-sensitive microcavity arrays: A new platform for oxygen measurements in 3D cell cultures
Grün, C., Pfeifer, J., Liebsch, G., & Gottwald, E. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1111316 · Cited by 19
Gas transport mechanisms through gas-permeable membranes in microfluidics: A perspective
Seo, S., & Kim, T. (2023) · Biomicrofluidics · doi:10.1063/5.0169555 · Cited by 15
Real-Time, Continuous Monitoring of Tissue Chips as an Emerging Opportunity for Biosensing
Cognetti, J. S., & Miller, B. L. (2025) · Sensors · doi:10.3390/s25165153 · Cited by 14
“The various materials used in making microfluidic devices have different permeabilities to oxygen gas [73], highlighting the need for continuous monitoring of oxygen content in tissue chips.”
Microfluidics for in vitro fertilization: from science to clinical validation
Pensabene, V., Agate, F., Miranda, A. S., & Picton, H. M. (2025) · Human Reproduction Update · doi:10.1093/humupd/dmaf028 · Cited by 19
“Control of oxygen tension in microfluidic devices is possible (Rivera et al. , 2019), and can be accommodated both through the design of the device used and by the selection of the manufacturing material, which allow improved modelling of the typical physiological gas concentrations in the oviduct…”
Integrative microphysiological tissue systems of cancer metastasis to the liver
Clark, A. M., Allbritton, N. L., & Wells, A. H. (2020) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.010 · Cited by 13
The promise of Synovial Joint-on-a-Chip in rheumatoid arthritis
Zhang, X., Su, R., Wang, H., Wu, R., Fan, Y., Bin, Z., Gao, C., & Wang, C. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1408501 · Cited by 13
“…to measure oxygen concentration colorimetric or fl uorescence sensors (61) and electrochemical microsensors to monitor pH (62), oxygen concentration (63), and cell metabolism (64), etc. OoC have been employed to simulate a wide range offunctional tissues or organs, encompassing the lung (39, 57, 65…”
MethodIn Vitro System for Evaluation of Biosensors in Controlled Dynamic Environmental Conditions
Ko, B. S., Zavareh, A. T., & McShane, M. J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3334366 · Cited by 10
“Different methods of controlling oxygen concentrations for in vitro sensor evaluation reported in the literature include the use of oxygen-scavenging reagents [18], [19], gas sparging [20], [21], [22], and microfluidics [23], [24], [25], [26].”
MethodThe Study of Microbial Physiology Under Microoxic Conditions Is Critical but Neglected
Prakash, O., Chauhan, A., & Green, S. J. (2025) · Environmental Microbiology Reports · doi:10.1111/1758-2229.70108 · Cited by 8
“Additional devices have been developed for real-time assessment of oxygen in tissues (Rivera et al. 2019), including polymer-based sensors (Lin et al. 2024) which can have broad detection ranges from 5 ppm to 90% (Wu et al. 2023).”
Cherukuri, R., Kim, S., Moyer, H. L., Jesse, H., Lam, P. Y., Richardson, L., Kammala, A. K., Menon, R., Rusyn, I., & Han, A. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c20917 · Cited by 10
Hypoxia Primes Human ISCs for Interleukin-Dependent Rescue of Stem Cell Activity
Rivera, K. R., Bliton, R. J., Burclaff, J., Czerwinski, M. J., Liu, J., Trueblood, J. M., Hinesley, C. M., Breau, K. A., Deal, H. E., Joshi, S., et al. (2023) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2023.07.012 · Cited by 11
Self-citationSønstevold, L., Koza, P., Czerkies, M., Andreassen, E., McMahon, P., & Vereshchagina, E. (2024) · Micromachines · doi:10.3390/mi15070898 · Cited by 6
“Specifically, the oxygen level pro-foundly influences cell metabolism, proliferation, differentiation, and, eventually, death [8].”
BackgroundGensheimer, T., Fuchs, S., de Heus, L. E., Vermeul, K., Mayr, T., & van der Meer, A. D. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500194 · Cited by 7
Roussakis, E., Cascales, J. P., Yoeli, D., Cralley, A. L., Goss, A., Wiatrowski, A., Carvalho, M., Moore, H. B., Moore, E. E., Huang, C. A., et al. (2024) · Sensors & Diagnostics · doi:10.1039/d3sd00240c · Cited by 5
Construction, evaluation, and applications of renal barrier-on-a-chip system
Naren, T., Lv, W., Aazmi, A., Wang, Y., Yu, H., Lee, J. Y., Yang, H., Yu, M., Jiang, X., Yang, H., et al. (2026) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.12.032 · Cited by 4
Torelli, F. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1743209 · Cited by 5
“At each depth point, corresponding z-stack images were acquired using a confocal microscope (Zeiss LSM 710, 10× NA 0.45 objective) under the same geometric reference frame (Rivera et al., 2019).”
InfluentialNayak, S., Sondkar, A., Vinchurkar, G., Shirsath, S., Shintre, S., & Vaidhun, B. (2024) · Journal of Exploratory Research in Pharmacology · doi:10.14218/jerp.2023.00006s · Cited by 3
Frantz, N. L., Brakoniecki, G., Chen, D., & Proshlyakov, D. A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02910 · Cited by 3
Sun, T., Yu, X., Turner, F., & Bao, X. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25052987 · Cited by 2
“Mass transfers inside the scaffolds (e.g., cell seeding, nutrient supply, and metabolic waste removal) primarily rely on restricted diffusion [6,15,16].”
BackgroundSitte, Z. R., Miranda, A. A., DiProspero, T. J., & Lockett, M. R. (2024) · HardwareX · doi:10.1016/j.ohx.2024.e00556 · Cited by 3
“22.”
BackgroundGoto, S., & Komori, K. (2025) · ChemistrySelect · doi:10.1002/slct.202504518 · Cited by 1
Rivera, K. R., Bliton, R. J., Burclaff, J., Czerwinski, M. J., Liu, J., Trueblood, J. M., Hinesley, C. M., Breau, K. A., Joshi, S., Pozdin, V. A., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.01.31.524747
Self-citationMeasurement and analytical techniques
Grochala, D., Paleczek, A., López‐Muñoz, G. A., & Rydosz, A. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15384-6.00003-3
Precise dynamic control of tissue oxygenation during brain slice electrophysiology
Jurado, A., Pérez-González, A., Farré, R., Gozal, D., Gasull, X., & Almendros, I. (2025) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00846.2025
Edmunds, S. J., Mallari, N. S. D., Levy, M. N., Liang, Q., Tahir, A., Meganathan, D. P., Tang, L., Sadr, L., Lampert, J., Shipley, W., et al. (2026) · ACS Applied Polymer Materials · doi:10.1021/acsapm.5c04718
Hypoxia-on-chip : from technological developments to biological applications
Bouquerel, C. (2023) · theses.fr (ABES) · doi:10.70675/d7d58b5dzd927z4235z8c54z8dbb6fd4757e · Cited by 1
Huang, E., Nolasco, J. A., Jones, S. J., & Lockett, M. R. (2026) · The Analyst · doi:10.1039/d5an01351h
A millifluidic human gut model with peristalsis orchestrates villus morphogenesis
Daddi, C., Maharjan, S., Scalzo, S., Anaya, S. N., Falugiani, L., Machain, X. H., Lobo, A. O., Fortunato, G. M., Maria, C. D., Zhang, Y. S., et al. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.112189
Николаевич, К. А., Krasnoselskaya, E. N., Khanova, A. R., & Николаевич, Ф. С. (2026) · Biomaterials Advances · doi:10.1016/j.bioadv.2026.215141
Navigating hypoxia in tissue engineering: From biological mechanisms to therapeutic strategies
Vieira, B., Cerqueira, A., Nunes, P. J., & Mano, J. F. (2026) · Acta Biomaterialia · doi:10.1016/j.actbio.2026.10.041
Biosensing Critical Markers of the Ocular Surface Microenvironment: Evolution and Frontiers
Roy, D., & Ranganath, S. H. (2026) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1177/10807683261497210
Metadata
- Authors
- Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Corresponding author
- Daniele, Michael
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2019
- Volume
- 144
- Issue
- 10
- Pages
- 3190-3215
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- PMC
- PMC6564678
- OpenAlex
- W2935119823
- Cited by
- 57
- References
- 240
- Citations by year
- 2026: 9 · 2025: 7 · 2024: 11 · 2023: 9 · 2022: 11 · 2021: 6 · 2020: 4
- FWCI
- 0.42
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (F31DK118859-02)
- National Science Foundation (EEC1160483)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- microphysiological systems, oxygen regulation, oxygen sensors, oxygen microenvironment, angiogenesis, carcinogenesis, cellular metabolism, oxygen partial pressure
- MeSH terms
- Animals, Cell Line, Humans, Models, Biological, Oxygen, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.