CoChat

Measuring and regulating oxygen levels in microphysiological systems: design, material, and sensor considerations

Open access

The DOI matches its Crossref record; 240 of the 240 references it cites were found in a registry or an index.

Abstract

Quantifying and regulating oxygen in a microphysiological models can be achieved via an array of technologies, and is an essential component of recapitulating tissue-specific microenvironments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c8an02201a

Cites

240 of 240 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 8

  1. Merkel TC, Bondar VI, Nagai K, Freeman BD and Pinnau I, J Polym Sci Pol Phys, 2000, 38, 415– 434. · DOI · Paper page
  2. Shuk P and Jantz R, 2015 9th International Conference on Sensing Technology (Icst), 2015, 12– 17.
  3. Hauser CJ, Locke RR, Kao HW, Patterson J and Zipser RD, J Lab Clin Med, 1988, 112, 68– 71. 3392458
  4. Park J, Youngmi KP, James JP, Sensors and Actuators B: Chemical, 2010, 147, 263– 269. · DOI
  5. Kieninger J, Dannenberg A, Aravindalochanan K, Jobst G, Pettersen EO and Urban GA, Transducers ‘07 & Eurosensors Xxi, Digest of Technical Papers, Vols 1 and 2, 2007.
  6. Sin A, Chin KC, Jamil MF, Kostov Y, Rao G and Shuler ML, Biotechnol Prog, 2004, 20, 338– 345. 14763861 · DOI · Paper page
  7. Nourmohammadzadeh M, Lo JF, Bochenek M, Mendoza-Elias JE, Wang Q, Li Z, Zeng L, Qi M, Eddington DT, Oberholzer J and Wang Y, Anal Chem, 2013, 85, 11240– 11249. 24083835 PMC3921903 · DOI
  8. Gitlin L, Hoera C, Meier RJ, Nagl S and Belder D, Lab Chip, 2013, 13, 4134– 4141. 23970303 · DOI

Cited by

See all 57

Metadata

Authors
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M.
Affiliations
University of North Carolina at Chapel Hill (US)
Corresponding author
Daniele, Michael
Venue
The Analyst
Published
2019
Volume
144
Issue
10
Pages
3190-3215
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2935119823
Cited by
57
References
240
Citations by year
2026: 9 · 2025: 7 · 2024: 11 · 2023: 9 · 2022: 11 · 2021: 6 · 2020: 4
FWCI
0.42
Type
journal article
Language
en
Open access
Locations
  • The Analyst (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institute of Diabetes and Digestive and Kidney Diseases (F31DK118859-02)
  • National Science Foundation (EEC1160483)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
microphysiological systems, oxygen regulation, oxygen sensors, oxygen microenvironment, angiogenesis, carcinogenesis, cellular metabolism, oxygen partial pressure
MeSH terms
Animals, Cell Line, Humans, Models, Biological, Oxygen, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.