A fluorometric skin-interfaced microfluidic device and smartphone imaging module for in situ quantitative analysis of sweat chemistry
The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
Abstract
A wearable microfluidic system and smartphone optics module enabled in situ analysis of sweat.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The last method is the fluorescence approach, where the wavelength of the light emitted is larger than the wavelength received, which is more sensitive and suitable for trace substance measurement.[238]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [238]
In the citing paper
“Sekine et al. [23] developed a wearable fluorometric sensor in the form of a soft, skin-interfaced microfluidic system to detect Na+, Cl−, and zinc (Zn2+) from eccrine sweat(Figure 1l).”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [23]
In the citing paper
“After pairing with the smartphone imaging module, we can monitor sweat biomarkers with an accuracy comparable to conventional laboratory equipment.”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [23]
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Synthesis and applications of Rhodamine derivatives as fluorescent probes
Beija, M., Afonso, C. A. M., & Martinho, J. M. G. (2009) · Chemical Society Reviews · doi:10.1039/b901612k · Cited by 1,463
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationLee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
Research works printed but not linked: 4
- P. Wei , B.Morey , T.Dyson , N.McMahon , Y.Hsu , S.Gazman , L.Klinker , B.Ives , K.Dowling and C.Rafferty , Proc. IEEE Sens , Baltimore, MD, USA , 2013 , vol. 32
- Roda, 2014, Anal. Chem., 139, 6494
- D. Armani , C.Liu and N.Aluru , MEMS '99; 12th IEEE International Conference , 17–21 Jan, 1999 , pp. 222–227
- N. MacKinnon , F.Vasefi , N.Booth and D. L.Farkas , Proc. of SPIE , 2016 , vol. 9711 , p. 971117
Cited by
Items 201–242 of 242
Surface Biochemical Modification of Poly(dimethylsiloxane) for Specific Immune Cytokine Response
Laborie, E., Bayle, F., Bouville, D., Smadja, C., Dufour‐Gergam, E., & Ammar, M. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01188 · Cited by 5
Wearable optical patches for non-invasive sweat sensing
Shuai, Y., Wu, X., Cao, C., Chen, L., Guo, Y., Qu, L., & Dong, X. (2026) · Soft Science · doi:10.20517/ss.2025.138 · Cited by 4
Song, R., Cho, S., Kim, G., Shin, S., Yin, S., Liu, R., Zeng, R., Tu, J., Xiong, Y., Park, I., et al. (2026) · Device · doi:10.1016/j.device.2026.101107 · Cited by 5
Development and application of microfluidic sweat detection technology in mental health monitoring
Zhao, D., Chen, R., Jiang, S., Xie, W., Zhang, K., Zhao, J., Feng, S., & Bian, S. (2025) · View · doi:10.1002/viw.20240088 · Cited by 5
Optical technologies for multiparametric heart failure management beyond the hospital
Vidal, M., Assunção, A. S., Bastos, J. M., Pereira, S. O., Segerink, L. I., Morrin, A., & Leitão, C. (2025) · Talanta · doi:10.1016/j.talanta.2025.128640 · Cited by 4
Ren, M., Li, T., Huo, W., Guo, Y. F., Xia, Z., Ya, L., Niu, J., Önses, M. S., & Huang, X. L. (2023) · International Journal of Smart and Nano Materials · doi:10.1080/19475411.2023.2227129 · Cited by 4
“Flexible wearable sensors for chemical detection are currently primarily achieved by amperometric [1,2], potentiometric [3,4], voltammetric [5,6], fluorescent [7–9], colorimetric [10,11], and surface-enhanced Raman scattering [12,13] approaches.”
BackgroundWearable biofluids colorimetric biosensors
Lyu, Z., Xiao, Z., Shen, W., Liu, C., Gu, T., Cao, R., Zhang, F., Meng, C., & Ding, S. (2026) · FlexMat. · doi:10.1002/flm2.70081 · Cited by 3
Saleheen, A., Campbell, B. M., Prosser, R. A., & Baker, C. A. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02505-y · Cited by 3
Darkening of Laser‐Induced Graphene in Wet for Readable In Situ Real Time Sweating Rate Analysis
Niu, P., Liu, Y., Wang, X., Yu, B., He, A., Chen, M., & She, X. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202102026 · Cited by 3
Thin film biosensors for medical diagnostics: Journey so far
Bhattacharyya, N., Jain, S., Bhattacharyya, S., Pal, S., Jana, A., & Mukherjee, S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96020-5.00058-3 · Cited by 3
Li, Y., Liu, Y., Leach, M. P., Hoettges, K. F., Zhang, Q., & Song, P. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3575581 · Cited by 2
Yang, M., Wang, C., Lai, X., Cai, J. H., & Zhou, W. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/ae0e89 · Cited by 2
“In a channel of known dimensions, the sweating rate can be inferred by analyzing the color variation and the length of the color-changing region [21, 22].”
Mo, Q., Huang, Z., Luo, Z., Lin, F., Li, B., Xu, H., Sun, Y., Song, J., Weng, X., Liu, L., et al. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.139446 · Cited by 3
Esfandiar, M., Hosseinalipour, S. M., & Salehi, S. M. (2026) · Engineering Reports · doi:10.1002/eng2.70593 · Cited by 2
Ausri, I. R., Zilberman, Y., Schneider, S. C., & Tang, X. S. (2023) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2023.100405 · Cited by 7
Processes in biosensor design, development, and validation parameters
Kalaiyarasan, G., & Joseph, J. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-19039-1.00002-x · Cited by 4
Research progress in wearable optical sweat sensors
Chen, Z., Chen, Y., Chen, C., Zhong, X., Qin, L., & Zhang, X. (2024) · Scientia Sinica Chimica · doi:10.1360/ssc-2024-0014 · Cited by 2
Fluorometric Sensors and Devices for Biomarkers
Kumar, P., Mutreja, V., Singh, A. S. G., Watts, J., & Li, Q. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/9781837673230-00095 · Cited by 2
Power-Free Sweat Sample Concentration Using a Silica-Gel-Packed PDMS Microchannel
Hirama, H., & Hayase, M. (2026) · Polymers · doi:10.3390/polym18020260 · Cited by 1
“Sekine et al. developed a skin-adhesive microfluidic device capable of in situ analysis of electrolytes in sweat, demonstrating the quantification of sweat components during exercise via fluorescence intensity measurements [9].”
Sweat-Based Wearable Electronic Devices for Health Monitoring: Materials, Devices, and Applications
Zheng, L., Abudusaimaiti, M., Wang, C., Hou, X., Wang, Z., Liu, Y., Feng, X., Xu, X., Li, H., Zhang, D., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.6c01211 · Cited by 1
Tonello, S., Hosseinzadeh, B., Lopomo, N. F., & Sardini, E. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3709497 · Cited by 1
“…limitations, emerging technologies—including microfluidics / millifluidics, hydrogels, epidermal systems, or sealed chambers [17], [18], [19], [20], [21]—enable continuous, real-time monitoring via impedance, optical, or water vapor sensing [22], e ff ectively minimizing evaporation during sampling.”
Smartphone-enabled miniaturized analytical devices
Ghoorchian, A., Jalal, N. R., Kamalabadi, M., Mollarasouli, F., Moradi, M., Asadi, S., Afkhami, A., Madrakian, T., Thomas, S., Nguyen, T. A., et al. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823727-4.00005-5 · Cited by 1
Yang, Q., Nguyen, E. P., Silva, C. D. C. C., Rosati, G., & Merkoçi, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00005-7 · Cited by 3
Amreen, K., & Goel, S. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_7 · Cited by 1
Automatic Extraction of Heat Maps and Goal Instances of a Basketball Game Using Video Processing
Eberle, G., Bourlot, J., Martínez, C., & Albornoz, E. M. (2022) · Communications in computer and information science · doi:10.1007/978-3-031-05903-2_7 · Cited by 1
Askari, V. R., Roudi, H. S., Safaei, R., Slamani, N., Nikfarjam, M., Shirazi, S. S., Fadaei, M. S., Hasnain, M. S., & Nayak, A. K. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21658-9.00018-8 · Cited by 1
Wearable Sensors and Deep Learning for the Management of Acute Pancreatitis in Precision Medicine
Liu, Q., Jiang, Y., Yu, R., & Poon, C. C. Y. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00068-6 · Cited by 3
Sweat-based screening of biomarkers using an enzymatic bioelectrocatalytic approach
Michelraj, S., Mechoor, A., & Ganesh, V. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-19039-1.00014-6
Smartphone-based point-of-care device
Aliyeva, N., Saylan, Y., & Denizli, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00027-2
Huang, L., Hao, T., Zhang, C., Shi, J., Yao, J., & Xu, J. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.114101
Self-Powered Uric Acid Monitoring with CuInSe 2 Nanozyme Catalysts
Zhao, X., Li, J., Li, H., Xie, G., & Su, Y. (2025) · ACS Applied Nano Materials · doi:10.1021/acsanm.5c04150
Design and Implementation of a Wearable Electrochemical Sweat Sensing Platform on Smart Eyeglasses
Acar, M. A., & Carminati, M. (2025) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine66377.2025.11340080
Optical Sensors for Point-of-Care Devices
Dalmieda, J. (2026) · Springer eBooks · doi:10.1007/978-981-95-5519-2_7
Laborie, E. (2021) · theses.fr (ABES) · doi:10.70675/b6bfae86zb344z4e7bz8581z483b70c63f21 · Cited by 1
Body‐integrated photonic biosensors: Illuminating the path to active healthcare
Gu, J., Wen, X., Yan, Q., ZHAO, Y., Yuan, L., Chen, S., Ma, Y., 方正月, Lei, D., Liu, Y., et al. (2026) · FlexMat. · doi:10.1002/flm2.70098 · Cited by 1
Recent Advances in Wearable Biosensors for Stress and Emotion Monitoring
Y, X., Wang, J., Gao, X., Zhang, Y., & Wen, D. (2026) · Advanced Sustainable Systems · doi:10.1002/adsu.70509
Self-citationSaranya, R., Jagadheeswari, B., V, Lavanya, G., Kumar, N. S., Rasheedha, A., & Chamundeswari, K. (2026) · International Conference on Intelligent Technologies (CONIT) · doi:10.1109/conit69683.2026.11621564
“Since wearable devices typically operate without external pumps, the microchannel architecture must enable reliable passive fluid transport while minimizing dead volumes and flow stagnation [14].”
InfluentialPerception‐Feedback Mapping Strategies for Flexible Human–Machine Interfaces
Yang, R., Xu, S., Pang, W., & Zhang, Y. (2026) · Advanced Materials · doi:10.1002/adma.74589
“Flexible chemical sensors can be realized through electrochemical [ 76, 77 ], chemiresistive [ 78 ], or colorimetric approaches [ 79 ].”
Self-citationPassive Sensor Based on CSRR for Monitoring Na + Concentration in Sweat
Zhao, B., & Chen, L. (2026) · International Conference on Artificial Intelligence and Electromechanical Automation (AIEA) · doi:10.1109/aiea70743.2026.11632584
“Reference[13] proposes a fluorescence sensing mode integrated within a microfluidic system.”
Yin, F., Lu, C., Kang, K., Hu, Y., Li, H., & Guo, X. (2026) · Electronics · doi:10.3390/electronics15194359
Skin-Derived Non-Coding RNAs as Potential Biomarkers and Therapeutic Targets
Zen, J. L., Le, Q. M. N., Li, S., & Hanna, G. B. (2026) · Non-Coding RNA · doi:10.3390/ncrna12050038
“These findings support the idea that ISF can serve as an accessible intermediary that may reflect both local tissue activity and systemic molecular signatures [10,26–31].”
Suea‐Ngam, A., Wirojsaengthong, S., Puthongkham, P., & Rodthongkum, N. (2026) · The Analyst · doi:10.1039/d6an00751a
Metadata
- Authors
- Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., Sugita, T., Wu, Y., Lee, K., Lee, K.-T., Ghaffari, R., & Rogers, J. A.
- Affiliations
- Japan Atomic Energy Agency (JP)
- University of Illinois Urbana-Champaign (US)
- Northwestern University (US)
- Keio University (JP)
- Southern Illinois University Carbondale (US)
- Corresponding author
- Sekine, Yurina
- Rogers, John A.
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 18
- Issue
- 15
- Pages
- 2178-2186
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2810554630
- Cited by
- 242
- References
- 44
- Citations by year
- 2026: 21 · 2025: 33 · 2024: 29 · 2023: 29 · 2022: 37 · 2021: 32 · 2020: 35 · 2019: 21 · 2018: 5
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Air Force Research Laboratory (FA8650-14-D-6516)
- Japan Society for the Promotion of Science (JP16K21604)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- sweat analysis, fluorescence sensing, wearable sensors, point-of-care testing, chloride determination, sodium determination, fluorescent probes, sweat biomarkers, wearable devices
- MeSH terms
- Smartphone, Chlorides, Fluorometry, Humans, Skin, Sodium, Sweat, Zinc, Lab-On-A-Chip Devices, Molecular Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.