A fluorometric skin-interfaced microfluidic device and smartphone imaging module for in situ quantitative analysis of sweat chemistry
The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.
Abstract
A wearable microfluidic system and smartphone optics module enabled in situ analysis of sweat.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The last method is the fluorescence approach, where the wavelength of the light emitted is larger than the wavelength received, which is more sensitive and suitable for trace substance measurement.[238]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [238]
In the citing paper
“Sekine et al. [23] developed a wearable fluorometric sensor in the form of a soft, skin-interfaced microfluidic system to detect Na+, Cl−, and zinc (Zn2+) from eccrine sweat(Figure 1l).”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [23]
In the citing paper
“After pairing with the smartphone imaging module, we can monitor sweat biomarkers with an accuracy comparable to conventional laboratory equipment.”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [23]
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Synthesis and applications of Rhodamine derivatives as fluorescent probes
Beija, M., Afonso, C. A. M., & Martinho, J. M. G. (2009) · Chemical Society Reviews · doi:10.1039/b901612k · Cited by 1,463
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationLee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Biology of sweat glands and their disorders. I. Normal sweat gland function
Sato, K., Kang, W. H., Saga, K., & Sato, K. T. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70063-3 · Cited by 717
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Wei, Q., Qi, H., Luo, W., Tseng, D., Ki, S. J., Wan, Z., Göröcs, Z., Bentolila, L. A., Wu, T.-T., Sun, R., et al. (2013) · ACS Nano · doi:10.1021/nn4037706 · Cited by 452
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Self-citationFuard, D., Tzvetkova-Chevolleau, T., Decossas, S., Tracqui, P., & Schiavone, P. (2008) · Microelectronic Engineering · doi:10.1016/j.mee.2008.02.004 · Cited by 424
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
The physiology, pharmacology, and biochemistry of the eccrine sweat gland
Sato, K. (1977) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0037089 · Cited by 384
Re-configurable fluid circuits by PDMS elastomer micromachining
Armani, D., Liu, C., & Aluru, N. (1999) · Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291) · doi:10.1109/memsys.1999.746817 · Cited by 382
Smartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva
Oncescu, V., O'Dell, D., & Erickson, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50431j · Cited by 362
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201601355 · Cited by 315
Self-citationTattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 312
Self-citationHandbook of Biological Dyes and Stains: Synthesis and Industrial Applications
Sabnis, R. W. (2010) · Wiley eBooks · doi:10.1002/9780470586242 · Cited by 309
Neural control and mechanisms of eccrine sweating during heat stress and exercise
Shibasaki, M., Wilson, T. E., & Crandall, C. G. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01124.2005 · Cited by 307
Formulation and stability of a novel artificial human sweat under conditions of storage and use
Harvey, C. J., LeBouf, R. F., & Stefaniak, A. B. (2010) · Toxicology in Vitro · doi:10.1016/j.tiv.2010.06.016 · Cited by 274
Wearable temporary tattoo sensor for real-time trace metal monitoring in human sweat
Kim, J., de Araujo, W. R., Samek, I. A., Bandodkar, A. J., Jia, W., Brunetti, B., Paixão, T. R. L. C., & Wang, J. (2015) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.11.024 · Cited by 245
Self-citationSweat: A sample with limited present applications and promising future in metabolomics
Mena-Bravo, A., & Luque de Castro, M. D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.10.048 · Cited by 235
Roda, A., Michelini, E., Cevenini, L., Calabria, D., Calabretta, M. M., & Simoni, P. (2014) · Analytical Chemistry · doi:10.1021/ac502137s · Cited by 222
An overview of the use of urine, hair, sweat and saliva to detect drug use
DOLAN, K., ROUEN, D., & KIMBER, J. (2004) · Drug and Alcohol Review · doi:10.1080/09595230410001704208 · Cited by 191
Kim, S. B., Zhang, Y., Won, S. M., Bandodkar, A. J., Sekine, Y., Xue, Y., Koo, J., Harshman, S. W., Martin, J. A., Park, J. M., et al. (2018) · Small · doi:10.1002/smll.201703334 · Cited by 167
Self-citationMeier, S. D., Kovalchuk, Y., & Rose, C. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.01.009 · Cited by 156
Choi, J., Xue, Y., Xia, W. J., Ray, T. R., Reeder, J. T., Bandodkar, A. J., Kang, D., Xu, S., Huang, Y. Y., & Rogers, J. A. (2017) · Lab on a Chip · doi:10.1039/c7lc00525c · Cited by 150
Self-citationSweat Composition in Relation to Rate of Sweating in Patients with Cystic Fibrosis of the Pancreas
Emrich, H. M., Stoll, E., Friolet, B., Colombo, J. P., Richterich, R., & Rossi, E. (1968) · Pediatric Research · doi:10.1203/00006450-196811000-00004 · Cited by 130
Human sweat metabolomics for lung cancer screening
Calderón-Santiago, M., Priego-Capote, F., Turck, N., Robin, X., Jurado-Gámez, B., Sanchez, J. C., & Luque de Castro, M. D. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8700-8 · Cited by 122
Sweat Iron and Zinc Losses during Prolonged Exercise
DeRuisseau, K. C., Cheuvront, S. N., Haymes, E. M., & Sharp, R. G. (2002) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.12.4.428 · Cited by 120
Effect of Training on Zinc Metabolism: Changes in Serum and Sweat Zinc Concentrations in Sportsmen
Córdova, A., & Navas, F. J. (1998) · Annals of Nutrition and Metabolism · doi:10.1159/000012744 · Cited by 72
Development and Critical Evaluation of Fluorescent Chloride Nanosensors
Graefe, A., Stanca, S. E., Nietzsche, S., Kubicová, L., Beckert, R., Biskup, C. U., & Mohr, G. J. (2008) · Analytical Chemistry · doi:10.1021/ac800115u · Cited by 70
Human perspiration measurement
Ohhashi, T., Sakaguchi, M., & Tsuda, T. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/4/001 · Cited by 68
Patterned Photonic Nitrocellulose for Pseudopaper ELISA
Chi, J., Gao, B., Sun, M., Zhang, F., Su, E., Liu, H., & Gu, Z. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01732 · Cited by 56
Hall, S. K., Stableforth, D. E., & Green, A. (1990) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329002700406 · Cited by 48
Peng, R., Sonner, Z., Hauke, A., Wilder, E., Kasting, J., Gaillard, T., Swaille, D., Sherman, F., Mao, X., Hagen, J., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc01013j · Cited by 43
Kan, T., Aoki, H., Binh-Khiem, N., Matsumoto, K., & Shimoyama, I. (2013) · Sensors · doi:10.3390/s130404138 · Cited by 38
Huber, C., Krause, C. H., Werner, T., & Wolfbeis, O. S. (2003) · Microchimica Acta · doi:10.1007/s00604-003-0034-0 · Cited by 30
Smartphone-based fluorescence spectroscopy device aiding in preliminary skin screening (Erratum)
Wahi, A., Jaiswal, S., Sahoo, A., Das, A. J., & Poojary, S. (2018) · Optics and Biophotonics in Low-Resource Settings · doi:10.1117/12.2289857 · Cited by 3
Research works printed but not linked: 4
- P. Wei , B.Morey , T.Dyson , N.McMahon , Y.Hsu , S.Gazman , L.Klinker , B.Ives , K.Dowling and C.Rafferty , Proc. IEEE Sens , Baltimore, MD, USA , 2013 , vol. 32
- Roda, 2014, Anal. Chem., 139, 6494
- D. Armani , C.Liu and N.Aluru , MEMS '99; 12th IEEE International Conference , 17–21 Jan, 1999 , pp. 222–227
- N. MacKinnon , F.Vasefi , N.Booth and D. L.Farkas , Proc. of SPIE , 2016 , vol. 9711 , p. 971117
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationSkin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
Metadata
- Authors
- Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., Sugita, T., Wu, Y., Lee, K., Lee, K.-T., Ghaffari, R., & Rogers, J. A.
- Affiliations
- Japan Atomic Energy Agency (JP)
- University of Illinois Urbana-Champaign (US)
- Northwestern University (US)
- Keio University (JP)
- Southern Illinois University Carbondale (US)
- Corresponding author
- Sekine, Yurina
- Rogers, John A.
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 18
- Issue
- 15
- Pages
- 2178-2186
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2810554630
- Cited by
- 242
- References
- 44
- Citations by year
- 2026: 21 · 2025: 33 · 2024: 29 · 2023: 29 · 2022: 37 · 2021: 32 · 2020: 35 · 2019: 21 · 2018: 5
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Air Force Research Laboratory (FA8650-14-D-6516)
- Japan Society for the Promotion of Science (JP16K21604)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- sweat analysis, fluorescence sensing, wearable sensors, point-of-care testing, chloride determination, sodium determination, fluorescent probes, sweat biomarkers, wearable devices
- MeSH terms
- Smartphone, Chlorides, Fluorometry, Humans, Skin, Sodium, Sweat, Zinc, Lab-On-A-Chip Devices, Molecular Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.