The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Skin Melanin, Hemoglobin, and Light Scattering Properties can be Quantitatively Assessed In Vivo Using Diffuse Reflectance Spectroscopy
Open accessAbstract
Noninvasive and real-time analysis of skin properties is useful in a wide variety of applications. In particular, the quantitative assessment of skin in terms of hemoglobin and melanin content, as well as in terms of its light scattering properties, is a challenging problem in dermatology. We present here a technique for examining human skin, based on the in vivo measurement of diffuse reflectance spectra in the visible and near-infrared ranges of the electromagnetic spectrum. Spectra were measured by means of a fiber optic probe, and they were analyzed using an analytical model of light diffusion in the skin. The results of the analysis indicate that it is possible to obtain quantitative information about hemoglobin and melanin content, as well as basic information regarding the scattering properties of the skin.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“increased melanin reduces signal penetration into the blood-containing dermis, attenuating the AC component of the PPG signal.”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [10]
In the citing paper
“failing to correct for these errors exacerbates existing healthcare disparities [10,23,24,25,26]”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [10]
In the citing paper
“consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode [10,11,28].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [10]
In the citing paper
“previous research demonstrated that inaccurate PPG HR measurements occur up to 15% more frequently in dark skin as compared to light skin”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [23]
In the citing paper
“likely because darker skin contains more melanin which absorbs more green light than lighter skin.”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [23]
In the citing paper
“This effect has been documented by other investigators68 and it may account for some of the errors experienced by dark skin individuals utilizing wearable based on PPG68–71.”
From Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI) (2021) · cites this paper as [70]
Citations
Cites
Born, M., Wolf, E., Bhatia, A. B., Clemmow, P. C., Gabor, D., Stokes, A. R., Taylor, A. M., Wayman, P. A., & Wilcock, W. L. (1999) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,627
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Farrell, T. J., Patterson, M. S., & Wilson, B. C. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,380
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M. M., Grossman, M. C., Esterowitz, D., Webb, R. H., & Anderson, R. R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,090
Principles of color technology
Billmeyer, F. W., & Saltzman, M. (1981) · Cited by 814
van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 682
Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G. I., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Dam, J. V., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 532
Self-citationPerelman, L. T., Backman, V., Wallace, M. B., Zonios, G. I., Manoharan, R., Nusrat, A., Shields, S. J., Seiler, M., Lima, C., Hamano, T., et al. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.627 · Cited by 492
Self-citationKollias, N., Sayre, R. M., Zeise, L., & Chedekel, M. R. (1991) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/1011-1344(91)80147-a · Cited by 482
Self-citation
Research works printed but not linked: 1
- Press, 1992, 681
Cited by
Sorted by citations
Items 101–200 of 485
McMurdy, J. W., Jay, G. D., Suner, S., Trespalacios, F., & Crawford, G. P. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2167967 · Cited by 38
Gnanatheepam, E., Kanniyappan, U., Aruna, P. R., Koteeswaran, D., & Ganesan, S. (2015) · Optik · doi:10.1016/j.ijleo.2015.11.045 · Cited by 37
An Introduction to Light Interaction with Human Skin
Baranoski, G. V. G., & Krishnaswamy, A. (2004) · Revista de Informática Teórica e Aplicada · doi:10.22456/2175-2745.5961 · Cited by 37
Transdermal Diagnosis of Malaria Using Vapor Nanobubbles
Lukianova‐Hleb, E. Y., Bezek, S., Szigeti, R. G., Khodarev, A., Kelley, T. A., Hurrell, A., Berba, M., Kumar, N., D’Alessandro, U., & Lapotko, D. O. (2015) · Emerging infectious diseases · doi:10.3201/eid2107.150089 · Cited by 36
Magnetic resonance and fluorescence based molecular imaging technologies
Sosnovik, D. E., & Weissleder, R. (2005) · Birkhäuser Basel eBooks · doi:10.1007/3-7643-7426-8_3 · Cited by 36
Melanin quantification by in vitro and in vivo analysis of near‐infrared fluorescence
Kalia, S., Zhao, J., Zeng, H., McLean, D. I., Kollias, N., & Lui, H. (2017) · Pigment Cell & Melanoma Research · doi:10.1111/pcmr.12624 · Cited by 35
Self-citationCorreia, T., Gibson, A. P., & Hebden, J. C. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3484747 · Cited by 34
Szekely‐Klepser, G., Wade, K., Woolson, D., Brown, R. R., Fountain, S. T., & Kindt, E. K. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2005.08.002 · Cited by 34
Tissue Ablation: Applications and Perspectives
Keum, H., Çevik, E., Kim, J., Demirlenk, Y. M., Atar, D., Saini, G., Sheth, R. A., Deipolyi, A. R., & Öklü, R. (2024) · Advanced Materials · doi:10.1002/adma.202310856 · Cited by 33
PressureVision: Estimating Hand Pressure from a Single RGB Image
Grady, P. L., Tang, C., Brahmbhatt, S., Twigg, C. D., Wan, C., Hays, J. H., & Kemp, C. C. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-20068-7_19 · Cited by 34
Estimating physiological skin parameters from hyperspectral signatures
Vyas, S., Banerjee, A., & Burlina, P. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.057008 · Cited by 35
Estimation of postmortem interval based on the spectrophotometric analysis of postmortem lividity
Usumoto, Y., Hikiji, W., Sameshima, N., Kudo, K., Tsuji, A., & Ikeda, N. (2009) · Legal Medicine · doi:10.1016/j.legalmed.2009.09.008 · Cited by 32
Photonics‐based In Vivo total hemoglobin monitoring and clinical relevance
McMurdy, J. W., Jay, G. D., Suner, S., & Crawford, G. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910019 · Cited by 32
Lamola, A. A., & Russo, M. (2013) · Photochemistry and Photobiology · doi:10.1111/php.12167 · Cited by 31
Al-Amin, M., Cao, J., Naeem, M., Banna, H., Kim, M., Jung, Y., Chung, H. Y., Moon, H. R., & Yoo, J. (2016) · Drug Design Development and Therapy · doi:10.2147/dddt.s123759 · Cited by 31
Vasefi, F., MacKinnon, N. B., Saager, R. B., Kelly, K. M., Maly, T. J., Booth, N., Durkin, A. J., & Farkas, D. L. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.11.114001 · Cited by 31
Effect of surface roughness on determination of bulk tissue optical parameters
Ma, X., Lu, J. Q., & Hu, X. (2003) · Optics Letters · doi:10.1364/ol.28.002204 · Cited by 30
Study of a Ring-Type Surgical Pleth Index Monitoring System Based on Flexible PPG Sensor
Zhou, C., Wang, H., Zhang, Y., & Ye, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3041072 · Cited by 29
Squiers, J. J., Thatcher, J. E., Bastawros, D. S., Applewhite, A. J., Baxter, R. D., Yi, F., Quan, P., Yu, S., DiMaio, J. M., & Gable, D. R. (2021) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2021.06.478 · Cited by 29
Racial and skin color mediated disparities in pulse oximetry in infants and young children
Sharma, M., Brown, A. W., Powell, N. M., Rajaram, N., Tong, L., Mourani, P. M., & Schootman, M. (2024) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2023.12.006 · Cited by 29
He, Q., & Wang, R. K. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005625 · Cited by 29
Fear, E. J., Torkelsen, F. H., Zamboni, E., Chen, K., Scott, M. T. W., Jeffery, G., Baseler, H. A., & Kennerley, A. J. (2023) · Aging Cell · doi:10.1111/acel.14005 · Cited by 28
Phototherapy in the newborn: what’s new?
Yurdakök, M. (2015) · Journal of pediatric and neonatal individualized medicine · doi:10.7363/040255 · Cited by 28
Principles of Light-Skin Interactions
Yang, M. F., Tuchin, V. V., & Yaroslavsky, A. N. (2009) · Springer eBooks · doi:10.1007/978-1-84882-328-0_1 · Cited by 28
A Real-Time Contactless Pulse Rate and Motion Status Monitoring System Based on Complexion Tracking
Lin, Y.-C., Chou, N., Lin, G., Lin, G., & Lin, Y.-H. (2017) · Sensors · doi:10.3390/s17071490 · Cited by 28
Comparative evaluation of two simple diffuse reflectance models for biological tissue applications
Zonios, G. I., Bassukas, I. D., & Dimou, A. D. (2008) · Applied Optics · doi:10.1364/ao.47.004965 · Cited by 28
Self-citationVolkova, E., Perchik, A., Pavlov, K., Nikolaev, E., Ayuev, A., Park, J., Chang, N., Lee, W., Kim, J. Y., Doronin, A. A., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-40339-7 · Cited by 27
Sitiwin, E. I., Madigan, M. C., Gratton, E., Cherepanoff, S., Conway, R. M., Whan, R. M., & Macmillan, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-54871-y · Cited by 27
Ha, T., Javedan, H., Waterston, K., Naysmith, L., & Rees, J. L. (2003) · Pigment Cell Research · doi:10.1034/j.1600-0749.2003.00076.x · Cited by 27
Adnan, A., Yaroslavsky, A. N., Carroll, J. D., Selting, W. J., Juliano, A. F. T., London, W. B., Sonis, S. T., Duncan, C., & Treister, N. S. (2021) · Frontiers in Oral Health · doi:10.3389/froh.2021.689386 · Cited by 26
Karsten, A., Singh, A., Karsten, P. A., & Braun, M. W. H. (2012) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2012.01220.x · Cited by 26
Colour quality of facial prostheses in additive manufacturing
Sohaib, A., Amano, K., Xiao, K., Yates, J. M., Whitford, C., & Wuerger, S. M. (2018) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-017-1480-x · Cited by 26
Probing pain pathways with light
Wang, F., Bélanger, E., Paquet, M.-È., Côté, D. C., & Koninck, Y. D. (2016) · Neuroscience · doi:10.1016/j.neuroscience.2016.09.035 · Cited by 26
Impact of one-layer assumption on diffuse reflectance spectroscopy of skin
Hennessy, R., Markey, M. K., & Tunnell, J. W. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.2.027001 · Cited by 25
Gevaux, L., Adnet, C., Séroul, P., Clerc, R., Trémeau, A., Perrot, J., & Hébert, M. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.6.066002 · Cited by 25
Hamdy, O., Abdel‐Salam, Z. A., & Harith, M. A. (2020) · Analytical Methods · doi:10.1039/d0ay00324g · Cited by 25
The validation of smartphone applications for heart rate measurement
Pipitprapat, W., Harnchoowong, S., Suchonwanit, P., & Sriphrapradang, C. (2018) · Annals of Medicine · doi:10.1080/07853890.2018.1531144 · Cited by 27
A library based fitting method for visual reflectance spectroscopy of human skin
Verkruysse, W., Zhang, R., Choi, B., Lucassen, G. W., Svaasand, L. O., & Nelson, J. S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/1/005 · Cited by 24
Verkruysse, W., Jia, W., Franco, W., Milner, T. E., & Nelson, J. S. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20581 · Cited by 24
MECHANISMS OF LASER-TISSUE INTERACTION: I. OPTICAL PROPERTIES OF TISSUE
Ansari, M. A., & Mohajerani, E. (2011) · doi:10.22037/2010.v2i3.2619 · Cited by 24
Is spectral reflectance of the face a reliable biometric?
Uzair, M., Mahmood, A., Faisal Shafait, B., Nansen, C., & Mian, A. S. (2015) · Optics Express · doi:10.1364/oe.23.015160 · Cited by 23
Naglič, P., Pernuš, F., Likar, B., & Bürmen, M. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003973 · Cited by 23
Carotenoids and throat pouch coloration in the great frigatebird (Fregata minor)
Juola, F. A., McGraw, K. J., & Dearborn, D. C. (2007) · Comparative Biochemistry and Physiology Part B Biochemistry and Molecular Biology · doi:10.1016/j.cbpb.2007.10.010 · Cited by 23
A’Amar, O. M., Ley, R. D., & Bigio, I. J. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1803845 · Cited by 23
Hyperspectral optical imaging of human iris in vivo: characteristics of reflectance spectra
Medina, J. M., Pereira, L. M., Correia, H. T., & Nascimento, S. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3595710 · Cited by 23
Ischaemia-reperfusion injury in photodynamic therapy-treated mouse tumours
Korbelik, M., Sun, J., & Zeng, H. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6600792 · Cited by 23
Investigation on the influence of the skin tone on hyperspectral imaging for free flap surgery
Pachyn, E., Aumiller, M., Freymüller, C., Linek, M., Volgger, V., Büchner, A., Rühm, A., & Sroka, R. C. (2024) · Scientific Reports · doi:10.1038/s41598-024-64549-9 · Cited by 22
Zhang, X. U., van der Zee, P., Atzeni, I. M., Faber, D. J., van Leeuwen, T. G. J. M., & Sterenborg, H. J. C. M. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.12.127001 · Cited by 22
Harnessing color vision for visual oximetry in central cyanosis
Changizi, M. A., & Rio, K. W. (2009) · Medical Hypotheses · doi:10.1016/j.mehy.2009.07.045 · Cited by 22
Study of light propagation in Asian and Caucasian skins by means of the Boundary Element Method
Ansari, M. A., & Massudi, R. (2009) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2009.04.006 · Cited by 22
Photodynamic treatment of malignant melanoma with structured light: in silico Monte Carlo modeling
Doronin, A. A., Yakovlev, V. V., & Bagnato, V. S. (2024) · Biomedical Optics Express · doi:10.1364/boe.515962 · Cited by 21
Jahn, S., Faber, H., Zazzeroni, R., & Kärst, U. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6247 · Cited by 21
Morgan, M., Kostyuk, O., Brown, R. A., & Mudera, V. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1821 · Cited by 21
Fodor, L., Ullmann, Y., & Elman, M. (2010) · Springer eBooks · doi:10.1007/978-1-84996-456-2_2 · Cited by 20
Wavelet based feature extraction and visualization in hyperspectral tissue characterization
Denstedt, M., Bjørgan, A., Milanič, M., & Randeberg, L. L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004260 · Cited by 20
Erythema Persists Longer than One Year in Split-thickness Skin Graft Donor Sites
Danielsen, P. L., Jørgensen, L. N., Jørgensen, B., Karlsmark, T., & Ågren, M. S. (2013) · Acta Dermato Venereologica · doi:10.2340/00015555-1455 · Cited by 20
Topical applications of iron chelators in photosensitization
Juzeniene, A., Juzenas, P., Iani, V., & Moan, J. E. (2007) · Photochemical & Photobiological Sciences · doi:10.1039/b703861e · Cited by 20
Latreille, J., Gardinier, S., Ambroisine, L., Mauger, E., Tenenhaus, M., Guéhenneux, S., Morizot, F., Tschachler, E., & Guinot, C. (2007) · Skin Research and Technology · doi:10.1111/j.1600-0846.2007.00212.x · Cited by 20
Subcutaneous veins depth measurement using diffuse reflectance images
Goh, C. M., Subramaniam, R., Saad, M. N. M., Ali, S. A., & Mériaudeau, F. (2017) · Optics Express · doi:10.1364/oe.25.025741 · Cited by 19
Hyperspectral imaging and characterization of allergic contact dermatitis in the short‐wave infrared
Du, T., Mishra, D. K., Shmuylovich, L., Yu, A., Hurbon, H., Wang, S. T., & Berezin, M. Y. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000040 · Cited by 19
A reflectance model for non-contact mapping of venous oxygen saturation using a CCD camera
Li, J., Dunmire, B. L., Beach, K. W., & Leotta, D. F. (2013) · Optics Communications · doi:10.1016/j.optcom.2013.06.041 · Cited by 19
Bohnert, M., Walther, R., Roths, T., & Honerkamp, J. (2005) · International Journal of Legal Medicine · doi:10.1007/s00414-005-0541-0 · Cited by 19
Phan, T., Rowland, R. A., Ponticorvo, A., Le, B. C., Sharif, S. A., Kennedy, G. T., Wilson, R. H., & Durkin, A. J. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.3.036002 · Cited by 18
Sun, C., Wu, P., Chen, S.-T., Su, Y.-H., Wei, M., Wang, C.-Y., Gao, H.-C., Sung, K., & Liao, Y. (2020) · Biomedical Optics Express · doi:10.1364/boe.391451 · Cited by 18
Broatch, J. R., O’Riordan, S. F., Keske, M. A., Betik, A. C., Bishop, D. J., Halson, S. L., & Parker, L. (2021) · The FASEB Journal · doi:10.1096/fj.202002205rr · Cited by 18
Simple detection of absorption change in skin tissue using simulated spectral reflectance database
Das, K., Yuasa, T., Maeda, T., Nishidate, I., Funamizu, H., & Aizu, Y. (2021) · Measurement · doi:10.1016/j.measurement.2021.109684 · Cited by 18
Multi-spectral mapping of in vivo skin hemoglobin and melanin
Jakovels, D., Spīgulis, J., & Saknīte, I. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.853928 · Cited by 18
Nishidate, I., Minakawa, M., McDuff, D., Wares, M. A., Nakano, K., Haneishi, H., Aizu, Y., & Niizeki, K. (2020) · Biomedical Optics Express · doi:10.1364/boe.382270 · Cited by 18
Narayanan, S., Kurian, N. K., & Bhat, S. G. (2019) · BioNanoScience · doi:10.1007/s12668-019-00689-x · Cited by 17
Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation
Cheung, M. Y., Sabharwal, A., Coté, G. L., & Veeraraghavan, A. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3434344 · Cited by 23
Bergé‐Lefranc, D., Schäf, O., Denoyel, R., Bergé‐Lefranc, J., Guieu, R., Brunet, P., & Hornebecq, V. (2009) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2009.09.009 · Cited by 16
Schmid, D., Grabmer, C., Streif, D., Lener, T., Schallmoser, K., & Rohde, E. (2014) · Vox Sanguinis · doi:10.1111/vox.12200 · Cited by 16
Hengfoss, C., Kulcke, A., Mull, G., Edler, C., Püschel, K., & Well, E. J.-V. (2011) · Forensic Science International · doi:10.1016/j.forsciint.2011.05.014 · Cited by 16
Optical properties of biomimetic probes engineered from erythrocytes
Burns, J. M., Saager, R. B., Majaron, B., Jia, W., & Anvari, B. (2016) · Nanotechnology · doi:10.1088/1361-6528/28/3/035101 · Cited by 16
Lerche, C. M., Olsen, P., Nissen, C., Philipsen, P. A., & Wulf, H. C. (2019) · Pigment Cell & Melanoma Research · doi:10.1111/pcmr.12805 · Cited by 16
Reductive effect of ursodeoxycholic acid on bilirubin levels in neonates on phototherapy
Ughasoro, M. D., Adimorah, G. N., Chukwudi, N. K., Nnakenyi, I. D., Iloh, K. K., & Udemba, C. E. (2019) · Clinical and Experimental Gastroenterology · doi:10.2147/ceg.s207523 · Cited by 16
Enhanced Surgical Imaging: Laparoscopic Vessel Identification and Assessment of Tissue Oxygenation
Crane, N. J., McHone, B. R., Hawksworth, J. S., Pearl, J. P., DeNobile, J. W., Tadaki, D. K., Pinto, P. A., Levin, I. W., & Elster, E. A. (2008) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2008.01.013 · Cited by 16
Deducing effective light transport parameters in optically thin systems
Mazzamuto, G., Pattelli, L., Toninelli, C., & Wiersma, D. S. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/2/023036 · Cited by 16
Quantitative interpretations of Visible-NIR reflectance spectra of blood
Serebrennikova, Y. M., Smith, J. M., Huffman, D. E., Leparc, G. F., & García‐Rubio, L. H. (2008) · Optics Express · doi:10.1364/oe.16.018215 · Cited by 16
Numerical study of reflectance imaging using a parallel Monte Carlo method
Chen, C., Lu, J. Q., Li, K., Zhao, S., Brock, R. S., & Hu, X. (2007) · Medical Physics · doi:10.1118/1.2745241 · Cited by 16
Probing skin interaction with hydrogen peroxide using diffuse reflectance spectroscopy
Zonios, G. I., Dimou, A. D., & Galaris, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/019 · Cited by 16
Self-citationZhang, B., Li, H., Xu, L., Qi, L., Yao, Y., & Greenwald, S. E. (2021) · Journal of Sensors · doi:10.1155/2021/9995871 · Cited by 15
Abdelazeem, R. M., & Hamdy, O. (2022) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22731 · Cited by 15
Pinto, F., Mielewczik, M., Liebisch, F., Walter, A., Greven, H., & Rascher, U. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073234 · Cited by 15
Tomas Strömberg, A., Jonasson, H., Fredriksson, I., Nyström, F. H., & Larsson, M. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.057002 · Cited by 15
A nonlinear approach to surface-enhanced sensing in the short-wave infrared
Turley, H. K., & Camden, J. P. (2013) · Chemical Communications · doi:10.1039/c3cc49002e · Cited by 15
Optical Properties of Human Skin Phototypes and Their Correlation with Individual Angle Typology
da Cruz, L. B., Girasol, C. E., Coltro, P. S., Guirro, R. R. D. J., & Bachmann, L. (2023) · Photobiomodulation Photomedicine and Laser Surgery · doi:10.1089/photob.2022.0111 · Cited by 14
Minakawa, M., Wares, M. A., Nakano, K., Haneishi, H., Aizu, Y., Hayasaki, Y., Ikeda, T., Nagahara, H., & Nishidate, I. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.10.107001 · Cited by 14
Tyr, A., Heldring, N., & Zilg, B. (2024) · International Journal of Legal Medicine · doi:10.1007/s00414-024-03262-8 · Cited by 14
Niedorf, F., Jungmann, H., & Kietzmann, M. (2005) · Medical Physics · doi:10.1118/1.1851917 · Cited by 14
Devpura, S., Pattamadilok, B., Syed, Z., Vemulapalli, P., Henderson, M. D., Rehse, S. J., Hamzavi, I. H., Lim, H. W., & Naik, R. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.001664 · Cited by 14
Fluorescence spectroscopy for the detection of tongue carcinoma—validation in an animal model
Kurachi, C., Fontana, C. R., Rosa, L. E. B., & Bagnato, V. S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2937214 · Cited by 14
Rudraiah, P. S., Duadi, H., & Fixler, D. (2021) · OSA Continuum · doi:10.1364/osac.415509 · Cited by 13
Khatun, F., Aizu, Y., & Nishidate, I. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.3.033708 · Cited by 13
Assessment of facial video-based detection of atrial fibrillation across human complexion
Couderc, J., Page, A., Lutz, M., Tsouri, G. R., & HALL, B. W. (2022) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2022.08.003 · Cited by 13
Karsten, A., Singh, A., Karsten, P. A., & Braun, M. W. H. (2012) · Lasers in Medical Science · doi:10.1007/s10103-012-1079-2 · Cited by 13
Feasibility of Ionization-Mediated Pathway for Ultraviolet-Induced Melanin Damage
Mandal, M., Das, T., Grewal, B. K., & Ghosh, D. (2015) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.5b08750 · Cited by 13
A colorimetric comparison of sunless with natural skin tan
Amano, K., Xiao, K., Wuerger, S. M., & Meyer, G. F. (2020) · PLoS ONE · doi:10.1371/journal.pone.0233816 · Cited by 13
Bykowski, J. L., Kollias, N., & LaMuraglia, G. M. (2003) · Microvascular Research · doi:10.1016/j.mvr.2003.11.003 · Cited by 13
Self-citationLight interaction with human skin
Baranoski, G. V. G., & Krishnaswamy, A. (2008) · SIGGRAPH Asia Courses · doi:10.1145/1508044.1508071 · Cited by 13
Metadata
- Authors
- Zonios, G., Bykowski, J., & Kollias, N.
- Affiliations
- Harvard University (US)
- Corresponding author
- Kollias, Nikiforos
- Venue
- Journal of Investigative Dermatology
- Publisher
- Elsevier BV
- Published
- 2001-12
- Volume
- 117
- Issue
- 6
- Pages
- 1452-1457
- ISSN
- 0022-202X (ISSN-L)
- OpenAlex
- W2089724274
- Cited by
- 477
- References
- 30
- Citations by year
- 2026: 11 · 2025: 27 · 2024: 35 · 2023: 20 · 2022: 16 · 2021: 32 · 2020: 25 · 2019: 29 · 2018: 25 · 2017: 17 · 2016: 28 · 2015: 30 · 2014: 18 · 2013: 29 · 2012: 17
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Investigative Dermatology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Oncology › Cutaneous Melanoma Detection and Management
- Keywords
- skin melanin, light scattering properties, diffuse reflectance spectroscopy, in vivo skin measurement, optical fiber probe, visible and near-infrared spectra
- MeSH terms
- Fiber Optic Technology, Hemoglobins, Humans, Melanins, Models, Biological, Scattering, Radiation, Skin, Skin Pigmentation, Spectroscopy, Near-Infrared, Optical Fibers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review