Aims To assess the accuracy, reliability and measurement of glycaemic control associated with the Medtronic‐MiniMed Continuous Glucose Monitoring System (CGMS) in comparison with blood glucose self‐monitoring (BGSM) in Type 1 diabetic patients. Methods Type 1 diabetic patients (n = 18) underwent glucose monitoring by the CGMS for up to 3 days, when control was also assessed by BGSM performed eight times daily. Results Ninety‐five per cent of paired non calibration samples were in the clinically acceptable zones of the Clarke error grid, and 97% in a consensus grid. The median bias was 0.1 mmol/l and relative bias 15%. The failure rate of sensors was 28% of those initially inserted. The CGMS detected significantly more hypoglycaemia and post‐prandial hyperglycaemia, but total duration of hyperglycaemia, blood glucose oscillations and day‐to‐day variability were similarly assessed by CGMS and BGSM. Conclusions The CGMS has acceptable clinical accuracy. Detection by the CGMS of more hypoglycaemia and post‐prandial hyperglycaemia than BGSM promises a valuable tool for control assessment and optimization of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Self-citationGlucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Nonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 534
Metadata
- Authors
- Sachedina, N., & Pickup, J. C.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2003-11-24
- Volume
- 20
- Issue
- 12
- Pages
- 1012-1015
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1982137772
- Cited by
- 143
- References
- 4
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance assessment of the Medtronic‐MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects. https://app.cochat.ai/papers/10.1046/j.1464-5491.2003.01037.x
- The paper
- Sachedina, N., & Pickup, J. C. (2003). Performance assessment of the Medtronic‐MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects. Diabetic Medicine. https://doi.org/10.1046/j.1464-5491.2003.01037.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.