CoChat

Automated detection of diabetic retinopathy in digital retinal images: a tool for diabetic retinopathy screening

Usher, D., Dumskyj, M., Himaga, M., Williamson, T. H., Nussey, S., Boyce, J. · 2004 · Diabetic Medicine
Cited by 299

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Aims To develop a system to detect automatically features of diabetic retinopathy in colour digital retinal images and to evaluate its potential in diabetic retinopathy screening. Methods Macular centred 45° colour retinal images from 1273 patients in an inner city diabetic retinopathy screening programme. A system was used involving pre‐processing to standardize colour and enhance contrast, segmentation to reveal possible lesions and classification of lesions using an artificial neural network. The system was trained using a subset of images from 500 patients and evaluated by comparing its performance with a human grader on a test set of images from 773 patients. Results Maximum sensitivity for detection of any retinopathy on a per patient basis was 95.1%, accompanied by specificity of 46.3%. Specificity could be increased as far as 78.9% but was accompanied by a fall in sensitivity to 70.8%. At a setting with 94.8% sensitivity and 52.8% specificity, no cases of sight‐threatening retinopathy were missed (retinopathy warranting immediate ophthalmology referral or re‐examination sooner than 1 year by National Institute for Clinical Excellence criteria). If the system was implemented at 94.8% sensitivity setting over half the images with no retinopathy would be correctly identified, reducing the need for a human grader to examine images in 1/3 of patients. Conclusion This system could be used when screening for diabetic retinopathy. At 94.8% sensitivity setting the number of normal images requiring examination by a human grader could be halved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1464-5491.2003.01085.x

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Research works printed but not linked: 11

  1. Evans J, 1996, Blindness and partial sight in England and Wales April 1900–March 1991, Health Trends, 28, 5
  2. 10.1136/bmj.324.7341.849 · doi:10.1136/bmj.324.7341.849
  3. 10.1089/152091501300209543 · doi:10.1089/152091501300209543
  4. 10.1089/152091501300209534 · doi:10.1089/152091501300209534
  5. 10.1089/15209150050025267 · DOI
  6. 10.1016/S0169-2607(00)00064-X · doi:10.1016/s0169-2607(00)00064-x
  7. 10.1111/j.1442-9071.1998.tb01385.x · doi:10.1111/j.1442-9071.1998.tb01385.x
  8. 10.1038/eye.1997.166 · doi:10.1038/eye.1997.166
  9. 10.1038/eye.1991.24 · doi:10.1038/eye.1991.24
  10. 10.1007/BF00166760 · doi:10.1007/bf00166760
  11. 10.1038/eye.2000.80 · doi:10.1038/eye.2000.80

Cited by

Metadata

Authors
Usher, D., Dumskyj, M., Himaga, M., Williamson, T. H., Nussey, S., & Boyce, J.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2003-11-28
Volume
21
Issue
1
Pages
84-90
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2115278098
Cited by
299
References
23
FWCI
1.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.