The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Abstract
A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Evans, R. D., & Beiser, A. (1955) · Cited by 1,814
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Self-citationOllinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Self-citationHubbell, J. H. (1969) · doi:10.6028/nbs.nsrds.29 · Cited by 598
(2014) · Nuclear Medicine · doi:10.1016/b978-0-323-08299-0.00003-1 · Cited by 578
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
(2012) · Elsevier eBooks · doi:10.1016/c2009-0-51635-2 · Cited by 459
Review of photon interaction cross section data in the medical and biological context
Hubbell, J. H. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/1/001 · Cited by 444
Burger, C., Goerres, G., Schoenes, S., Buck, A., Lonn, A., & von Schulthess, G. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0796-3 · Cited by 428
PET-CT image co-registration in the thorax: influence of respiration
Goerres, G. W., Kamel, E., Heidelberg, T.-N. H., Schwitter, M. R., Burger, C., & von Schulthess, G. K. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0710-4 · Cited by 332
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281
The Theory and Practice of 3D PET
(1998) · Springer eBooks · doi:10.1007/978-94-017-3475-2 · Cited by 223
Statistical approaches in quantitative positron emission tomography
Leahy, R. M., & Qi, J. (2000) · Statistics and Computing · doi:10.1023/a:1008946426658 · Cited by 215
Transmission scanning in emission tomography
Bailey, D. L. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050282 · Cited by 202
Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans.
Antoch, G., Freudenberg, L. S., Egelhof, T., Stattaus, J., Jentzen, W., Debatin, J. F., & Bockisch, A. (2002) · PubMed · Cited by 201
Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels
Comtat, C., Kinahan, P. E., Fessler, J. A., Beyer, T., Townsend, D. W., Defrise, M., & Michel, C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/301 · Cited by 178
Self-citationBlankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.531891 · Cited by 170
Self-citationImage Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner
CHARRON, M., BEYER, T., BOHNEN, N. N., KINAHAN, P. E., DACHILLE, M., JERIN, J., NUTT, R., MELTZER, C. C., VILLEMAGNE, V., & TOWNSEND, D. W. (2000) · Clinical Nuclear Medicine · doi:10.1097/00003072-200011000-00010 · Cited by 170
Self-citationFast reconstruction of 3D PET data with accurate statistical modeling
Comtat, C., Kinahan, P. E., Defrise, M., Michel, C., & Townsend, D. W. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.681983 · Cited by 165
Self-citationNakamoto, Y., Osman, M., Cohade, C., Marshall, L. T., Links, J. M., Kohlmyer, S. G., & Wahl, R. L. (2002) · PubMed · Cited by 161
Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants
Goerres, G. W., Hany, T. F., Kamel, E. M., von Schulthess, G. K., & Buck, A. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0721-1 · Cited by 156
Kamel, E. M., Hany, T. F., Burger, C., Treyer, V., Lonn, A. H. R., von Schulthess, G. K., & Buck, A. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0698-9 · Cited by 152
Investigation of the use of X-ray CT images for attenuation compensation in SPECT
LaCroix, K. J., Tsui, B. M. W., Hasegawa, B. H., & Brown, J. K. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.340649 · Cited by 142
Self-citationRobinson, P. J., & Kreel, L. (1979) · PubMed · Cited by 131
Pulmonary Tissue Attenuation with Computed Tomography
Robinson, P. J., & Kreel, L. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197903060-00006 · Cited by 125
Attenuation correction in PET using single photon transmission measurement
deKemp, R. A., & Nahmias, C. (1994) · Medical Physics · doi:10.1118/1.597394 · Cited by 123
Adaptive, segmented attenuation correction for whole-body PET imaging
Xu, M., Cutler, P. D., & Luk, W. K. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.485974 · Cited by 103
Object-specific attenuation correction of SPECT with correlated dual-energy X-ray CT
Hasegawa, B. H., Lang, T., Brown, J. K., Gingold, E. L., Reilly, S. M., Blankespoor, S. C., Liew, S. C., Tsui, B. M. W., & Ramanathan, C. (1993) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1993.8526573 · Cited by 83
Self-citationWeik, M. H. (2000) · Springer eBooks · doi:10.1007/1-4020-0613-6_13861 · Cited by 75
To AC or not to AC: that is the question.
Wahl, R. L. (1999) · PubMed · Cited by 54
Tang, H. R., Brown, J. K., Silva, A. J. D., Matthay, K. K., Price, D. C., Huberty, J. P., Hawkins, R. A., & Hasegawa, B. H. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775578 · Cited by 45
Self-citation
Cited by
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Kinahan, P. E., & Fletcher, J. W. (2010) · Seminars in Ultrasound, CT and MRI · doi:10.1053/j.sult.2010.10.001 · Cited by 631
Self-citationWhole-Body PET/CT Scanning: Estimation of Radiation Dose and Cancer Risk
Huang, B., Law, M. W.-M., & Khong, P.-L. (2009) · Radiology · doi:10.1148/radiol.2511081300 · Cited by 522
Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., Nekolla, S. G., Ziegler, S., Ganter, C., Rummeny, E. J., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.098608 · Cited by 508
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Metadata
- Authors
- Kinahan, P. E., Hasegawa, B. H., & Beyer, T.
- Venue
- Seminars in Nuclear Medicine
- Publisher
- Elsevier BV
- Published
- 2003-07
- Volume
- 33
- Issue
- 3
- Pages
- 166-179
- ISSN
- 0001-2998 (ISSN-L)
- OpenAlex
- W2126639779
- Cited by
- 515
- References
- 35
- FWCI
- 19.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.