Advanced imaging for detection and differentiation of colorectal neoplasia: European Society of Gastrointestinal Endoscopy (ESGE) Guideline
Open accessThe DOI matches its Crossref record; 286 of the 286 references it cites were found in a registry or an index.
Abstract
MAIN RECOMMENDATIONS: 1 ESGE suggests the routine use of high definition white-light endoscopy systems for detecting colorectal neoplasia in average risk populations (weak recommendation, moderate quality evidence). 2 ESGE recommends the routine use of high definition systems and pancolonic conventional or virtual (narrow band imaging [NBI], i-SCAN) chromoendoscopy in patients with known or suspected Lynch syndrome (strong recommendation, low quality evidence). 2b ESGE recommends the routine use of high definition systems and pancolonic conventional or virtual (NBI) chromoendoscopy in patients with known or suspected serrated polyposis syndrome (strong recommendation, low quality evidence). 3 ESGE recommends the routine use of 0.1 % methylene blue or 0.1 % - 0.5 % indigo carmine pancolonic chromoendoscopy with targeted biopsies for neoplasia surveillance in patients with long-standing colitis. In appropriately trained hands, in the situation of quiescent disease activity and adequate bowel preparation, nontargeted, four-quadrant biopsies can be abandoned (strong recommendation, high quality evidence). 4 ESGE suggests that virtual chromoendoscopy (NBI, FICE, i-SCAN) and conventional chromoendoscopy can be used, under strictly controlled conditions, for real-time optical diagnosis of diminutive (≤ 5 mm) colorectal polyps to replace histopathological diagnosis. The optical diagnosis has to be reported using validated scales, must be adequately photodocumented, and can be performed only by experienced endoscopists who are adequately trained and audited (weak recommendation, high quality evidence). 5 ESGE suggests the use of conventional or virtual (NBI) magnified chromoendoscopy to predict the risk of invasive cancer and deep submucosal invasion in lesions such as those with a depressed component (0-IIc according to the Paris classification) or nongranular or mixed-type laterally spreading tumors (weak recommendation, moderate quality evidence). CONCLUSION: Advanced imaging techniques will need to be applied in specific patient groups in routine clinical practice and to be taught in endoscopic training programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-performance medicine: the convergence of human and artificial intelligence
Topol, E. J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0300-7 · Cited by 10,450
Grading quality of evidence and strength of recommendations
(2004) · BMJ · doi:10.1136/bmj.328.7454.1490 · Cited by 8,477 · cited 1×
“For important outcomes, articles were individually assessed by using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system for grading evidence levels and recommendation strengths [8].”
Rajkomar, A., Dean, J., & Kohane, I. (2019) · New England Journal of Medicine · doi:10.1056/nejmra1814259 · Cited by 4,579
The well-built clinical question: A key to evidence-based decisions
(1995) · ACP Journal Club · doi:10.7326/acpjc-1995-123-3-a12 · Cited by 2,931
Japanese Society for Cancer of the Colon and Rectum, Watanabe, T., Muro, K., Ajioka, Y., Hashiguchi, Y., Ito, Y., Saito, Y., Hamaguchi, T., Ishida, H., Ishiguro, M., et al. (2018) · International Journal of Clinical Oncology · doi:10.1007/s10147-017-1101-6 · Cited by 2,467
Adenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
WINAWER, S. (2003) · Gastroenterology · doi:10.1053/gast.2003.50044 · Cited by 2,143
Quality Indicators for Colonoscopy and the Risk of Interval Cancer
Kaminski, M. F., Regula, J., Kraszewska, E., Polkowski, M., Wojciechowska, U., Didkowska, J., Zwierko, M., Rupinski, M., Nowacki, M. P., & Butruk, E. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907667 · Cited by 2,010
Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic Adults
Pickhardt, P. J., Choi, J. R., Hwang, I., Butler, J. A., Puckett, M. L., Hildebrandt, H. A., Wong, R. K., Nugent, P. A., Mysliwiec, P. A., & Schindler, W. R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031618 · Cited by 1,972
Lieberman, D. A., Rex, D. K., Winawer, S. J., Giardiello, F. M., Johnson, D. A., & Levin, T. R. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.06.001 · Cited by 1,892
Cited by
Ferlitsch, M., Moss, A., Hassan, C., Bhandari, P., Dumonceau, J.-M., Paspatis, G., Jover, R., Langner, C., Bronzwaer, M., Nalankilli, K., et al. (2017) · Endoscopy · doi:10.1055/s-0043-102569 · Cited by 1,108
Self-citationKaminski, M., Thomas-Gibson, S., Bugajski, M., Bretthauer, M., Rees, C., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., et al. (2017) · Endoscopy · doi:10.1055/s-0043-103411 · Cited by 885
Self-citationPrimary sclerosing cholangitis – a comprehensive review
Karlsen, T. H., Folseraas, T., Thorburn, D., & Vesterhus, M. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.07.022 · Cited by 868
“in the situation of quiescent disease and adequate bowel preparation (241, 243).”
BackgroundByrne, M. F., Chapados, N., Soudan, F., Oertel, C., Linares Pérez, M., Kelly, R., Iqbal, N., Chandelier, F., & Rex, D. K. (2019) · Gut · doi:10.1136/gutjnl-2017-314547 · Cited by 635
Hassan, C., Spadaccini, M., Iannone, A., Maselli, R., Jovani, M., Chandrasekar, V. T., Antonelli, G., Yu, H., Areia, M., Dinis-Ribeiro, M., et al. (2021) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.059 · Cited by 529
Self-citationMonahan, K. J., Bradshaw, N., Dolwani, S., Desouza, B., Dunlop, M. G., East, J. E., Ilyas, M., Kaur, A., Lalloo, F., Latchford, A., et al. (2020) · Gut · doi:10.1136/gutjnl-2019-319915 · Cited by 484
Self-citationRutter, M. D., East, J., Rees, C. J., Cripps, N., Docherty, J., Dolwani, S., Kaye, P. V., Monahan, K. J., Novelli, M. R., Plumb, A., et al. (2020) · Gut · doi:10.1136/gutjnl-2019-319858 · Cited by 380
Self-citationThe role of endoscopy in inflammatory bowel disease
Shergill, A. K., Lightdale, J. R., Bruining, D. H., Acosta, R. D., Chandrasekhara, V., Chathadi, K. V., Decker, G. A., Early, D. S., Evans, J. A., Fanelli, R. D., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.10.030 · Cited by 362
Kaminski, M. F., Thomas‐Gibson, S., Bugajski, M., Bretthauer, M., Rees, C. J., Dekker, E., Hoff, G., Jover, R., Suchanek, S., Ferlitsch, M., et al. (2017) · United European Gastroenterology Journal · doi:10.1177/2050640617700014 · Cited by 346
Self-citationBisschops, R., East, J. E., Hassan, C., Hazewinkel, Y., Kamiński, M. F., Neumann, H., Pellisé, M., Antonelli, G., Bustamante Balen, M., Coron, E., et al. (2019) · Endoscopy · doi:10.1055/a-1031-7657 · Cited by 340
Self-citationSeppälä, T. T., Latchford, A., Negoi, I., Sampaio Soares, A., Jimenez-Rodriguez, R., Sánchez-Guillén, L., Evans, D. G., Ryan, N., Crosbie, E. J., Dominguez-Valentin, M., et al. (2021) · British Journal of Surgery · doi:10.1002/bjs.11902 · Cited by 275
Artificial Intelligence in Colorectal Cancer Screening, Diagnosis and Treatment. A New Era
Mitsala, A., Tsalikidis, C., Pitiakoudis, M., Simopoulos, C., & Tsaroucha, A. K. (2021) · Current Oncology · doi:10.3390/curroncol28030149 · Cited by 271
Murthy, S. K., Feuerstein, J. D., Nguyen, G. C., & Velayos, F. S. (2021) · Gastroenterology · doi:10.1053/j.gastro.2021.05.063 · Cited by 267
Aabakken, L., Karlsen, T., Albert, J., Arvanitakis, M., Chazouilleres, O., Dumonceau, J.-M., Färkkilä, M., Fickert, P., Hirschfield, G., Laghi, A., et al. (2017) · Endoscopy · doi:10.1055/s-0043-107029 · Cited by 255
Self-citationArtificial Intelligence-assisted System Improves Endoscopic Identification of Colorectal Neoplasms
Kudo, S.-E., Misawa, M., Mori, Y., Hotta, K., Ohtsuka, K., Ikematsu, H., Saito, Y., Takeda, K., Nakamura, H., Ichimasa, K., et al. (2020) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2019.09.009 · Cited by 242
Advanced endoscopic imaging: European Society of Gastrointestinal Endoscopy (ESGE) Technology Review
East, J., Vleugels, J., Roelandt, P., Bhandari, P., Bisschops, R., Dekker, E., Hassan, C., Horgan, G., Kiesslich, R., Longcroft-Wheaton, G., et al. (2016) · Endoscopy · doi:10.1055/s-0042-118087 · Cited by 239
Self-citationAhmad, O. F., Soares, A. S., Mazomenos, E., Brandao, P., Vega, R., Seward, E., Stoyanov, D., Chand, M., & Lovat, L. B. (2019) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(18)30282-6 · Cited by 215
Rees, C. J., Rajasekhar, P. T., Wilson, A., Close, H., Rutter, M. D., Saunders, B. P., East, J. E., Maier, R., Moorghen, M., Muhammad, U., et al. (2017) · Gut · doi:10.1136/gutjnl-2015-310584 · Cited by 211
Self-citationDeep learning to find colorectal polyps in colonoscopy: A systematic literature review
Sánchez-Peralta, L. F., Bote-Curiel, L., Picón, A., Sánchez-Margallo, F. M., & Pagador, J. B. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101923 · Cited by 177
Zachariah, R., Samarasena, J., Luba, D., Duh, E., Dao, T., Requa, J., Ninh, A., & Karnes, W. (2020) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000000429 · Cited by 117
“Among 36,107 diminutive polyps in a large prospective database, only 0.3% of colonic polyps demonstrate high grade dysplasia and none were cancers [5][6].”
BackgroundInfluentialSato, Y., Tsujinaka, S., Miura, T., Kitamura, Y., Suzuki, H., & Shibata, C. (2023) · Cancers · doi:10.3390/cancers15164154 · Cited by 111
Aabakken, L., Karlsen, T. H., Albert, J., Arvanitakis, M., Chazouilleres, O., Dumonceau, J.-M., Färkkilä, M., Fickert, P., Hirschfield, G. M., Laghi, A., et al. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.02.013 · Cited by 107
“In appropriately trained hands, in the situation of quiescent disease activity and adequate bowel preparation, non-targeted four-quadrant biopsies can be abandoned [118].”
Self-citationScreening and Surveillance of Colorectal Cancer: A Review of the Literature
Maida, M., Dahiya, D. S., Shah, Y. R., Tiwari, A., Gopakumar, H., Vohra, I., Khan, A., Jaber, F., Ramai, D., & Facciorusso, A. (2024) · Cancers · doi:10.3390/cancers16152746 · Cited by 43
PEACE: Perception and Expectations toward Artificial Intelligence in Capsule Endoscopy
Leenhardt, R., Fernandez-Urien Sainz, I., Rondonotti, E., Toth, E., Van de Bruaene, C., Baltes, P., Rosa, B., Triantafyllou, K., Histace, A., Koulaouzidis, A., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10235708 · Cited by 30
Next-generation endoscopy in inflammatory bowel disease
Zammarchi, I., Santacroce, G., & Iacucci, M. (2023) · Diagnostics · doi:10.3390/diagnostics13152547 · Cited by 28
Polyp characterization using deep learning and a publicly accessible polyp video database
Kader, R., Cid‐Mejias, A., Brandao, P., Islam, S., Hebbar, S., Puyal, J. G., Ahmad, O. F., Hussein, M., Toth, D., Mountney, P., et al. (2023) · Digestive Endoscopy · doi:10.1111/den.14500 · Cited by 22
Metadata
- Authors
- Kamiński, M., Hassan, C., Bisschops, R., Pohl, J., Pellisé, M., Dekker, E., Ignjatovic-Wilson, A., Hoffman, A., Longcroft-Wheaton, G., Heresbach, D., Dumonceau, J.-M., & East, J.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2014-03-17
- Volume
- 46
- Issue
- 05
- Pages
- 435-457
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2005464795
- Cited by
- 433
- References
- 286
- FWCI
- 17.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.