Validity and Reliability of the Apple Watch for Measuring Heart Rate During Exercise
Open accessAbstract
We examined the validity and reliability of the Apple Watch heart rate sensor during and in recovery from exercise. Twenty-one males completed treadmill exercise while wearing two Apple Watches (left and right wrists) and a Polar S810i monitor (criterion). Exercise involved 5-min bouts of walking, jogging, and running at speeds of 4 km.h−1, 7 km.h−1, and 10 km.h−1, followed by 11 min of rest between bouts. At all exercise intensities the mean bias was trivial. There were very good correlations with the criterion during walking (L: r=0.97; R: r=0.97), but good (L: r=0.93; R: r=0.92) and poor/good (L: r=0.81; R: r=0.86) correlations during jogging and running. Standardised typical error of the estimate was small, moderate, and moderate to large. There were good correlations following walking, but poor correlations following jogging and running. The percentage of heart rates recorded reduced with increasing intensity but increased over time. Intra-device standardised typical errors decreased with intensity. Inter-device standardised typical errors were small to moderate with very good to nearly perfect intraclass correlations. The Apple Watch heart rate sensor has very good validity during walking but validity decreases with increasing intensity.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Three studies (23 comparisons) examined interdevice reliability for heart rate, with analyzed sample sizes ranging from 13 to 21.
“Three studies (23 comparisons) examined interdevice reliability for heart rate [24,26,58], with analyzed sample sizes ranging from 13 [24] to 21 [26].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [26]
Apple Watch showed very good interdevice reliability at 5-s epochs during treadmill bouts at 4, 7, and 10 km/h, with reliability increasing and standard typical error decreasing with increasing pace [26].
“Apple Watch showed very good interdevice reliability at 5-s epochs during treadmill bouts at 4, 7, and 10 km/h, with reliability increasing and standard typical error decreasing with increasing pace [26].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Heart-rate Recovery Immediately After Exercise as a Predictor of Mortality
Cole, C. R., Blackstone, E. H., Pashkow, F. J., Snader, C. E., & Lauer, M. S. (1999) · New England Journal of Medicine · doi:10.1056/nejm199910283411804 · Cited by 1,935 · see citing works
Warren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587 · see citing works
Update – Ethical Standards in Sport and Exercise Science Research
Harriss, D., & Atkinson, G. (2011) · International Journal of Sports Medicine · doi:10.1055/s-0031-1287829 · Cited by 508 · see citing works
Heart rate recovery: validation and methodologic issues
Shetler, K. P., Marcus, R. R., Froelicher, V. F., Vora, S., Kalisetti, D., Prakash, M., Do, D., & Myers, J. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01652-7 · Cited by 491 · see citing works
Accuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
Weippert, M., Kumar, M., Kreuzfeld, S., Arndt, D., Rieger, A., & Stoll, R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1415-9 · Cited by 302 · see citing works
Vanderlei, L. C. M., Silva, R. A., Pastre, C. M., de Azevedo, F. M., & de Godoy, M. F. (2008) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2008005000039 · Cited by 296 · see citing works
International Journal of Sports Medicine – Ethical Standards in Sport and Exercise Science Research
Harriss, D., & Atkinson, G. (2009) · International Journal of Sports Medicine · doi:10.1055/s-0029-1237378 · Cited by 295 · see citing works
Heart Rate Recovery Immediately After Exercise as a Predictor of Mortality
Cole, C. R., Blackstone, E. H., Pashkow, F. J., Snader, C. E. P., & Lauer, M. S. (2000) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-200003000-00012 · Cited by 134 · see citing works
Physical training and the control of skin blood flow
Johnson, J. M. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199803000-00007 · Cited by 86 · see citing works
Αναστασοπούλου, Π., Tubic, M., Schmidt, S., Neumann, R., Wöll, A., & Härtel, S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090606 · Cited by 80 · see citing works
Validity of the Smarthealth Watch to Measure Heart Rate During Rest and Exercise
Lee, C. M., & Gorelick, M. (2011) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2011.539089 · Cited by 42 · see citing works
Poor Reliability of Heart Rate Monitoring to Assess Oxygen Uptake During Field Training
Crisafulli, A., Pittau, G., Lorrai, L., et al. (2006) · International Journal of Sports Medicine · doi:10.1055/s-2005-837504 · Cited by 25 · see citing works
Heart Rate Unreliability during Interval Training Recovery in Middle Distance Runners.
Tocco, F., Sanna, I., Mulliri, G., et al. (2015) · PubMed · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Sañudo, B., De Hoyo, M., Muñoz-López, A., Perry, J., & Abt, G. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1325-2 · Cited by 48 · see citing works
Self-citation
- Authors
- Khushhal, A., Nichols, S., Evans, W., Gleadall-Siddall, D., Page, R., O'Doherty, A., Carroll, S., Ingle, L., & Abt, G.
- Affiliations
- University of Hull (GB)
- Sheffield Hallam University (GB)
- Northumbria University, Department of Sport, Exercise and Rehabilitation, Newcastle upon Tyne, United Kingdom of Great Britain and Northern Ireland
- Corresponding author
- Abt, Grant
- ORCID
- Venue
- Sports Medicine International Open
- Publisher
- Georg Thieme Verlag KG
- Published
- 2017-10
- Volume
- 1
- Issue
- 06
- Pages
- E206-E211
- ISSN
- 2367-1890 (ISSN-L)
- PMC
- PMC6226089
- OpenAlex
- W2766894515
- Cited by
- 92
- References
- 16
- Citations by year
- 2026: 6 · 2025: 20 · 2024: 16 · 2023: 8 · 2022: 8 · 2021: 11 · 2020: 12 · 2019: 9 · 2018: 1
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sports Medicine International Open (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Edinburgh Napier Research Repository (Edinburgh Napier University) (publishedVersion, other-oa)
- Sunderland Repository (University of Sunderland) (acceptedVersion)
- Repository@Hull (Worktribe) (University of Hull) (submittedVersion, cc-by-nc-nd)
- Repository@Hull (Worktribe) (University of Hull) (submittedVersion, other-oa)
- Northumbria Research Link (Northumbria University) (submittedVersion)
- Research at York St John (York St John University) (submittedVersion)
- SHURA (Sheffield Hallam University Research Archive) (Sheffield Hallam University) (submittedVersion)
- Durham Research Online (Durham University) (submittedVersion, cc-by)
- Open Access Institutional Repository at Robert Gordon University (Robert Gordon University) (submittedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Keywords
- Apple Watch, heart rate monitoring, wearable sensors, exercise intensity, treadmill exercise, heart rate recovery, measurement validity, measurement reliability, inter-device agreement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review