Cited by 92Non-Invasive Vital Sign MonitoringCardiovascular and exercise physiologyPhysical Activity and Health

Validity and Reliability of the Apple Watch for Measuring Heart Rate During Exercise

Open access
Khushhal, Alaa, Nichols, Simon, Evans, Will, Gleadall-Siddall, Damien, Page, Richard, O'Doherty, Alasdair, Carroll, Sean, Ingle, Lee +1 more·2017·Sports Medicine International Open

Abstract

We examined the validity and reliability of the Apple Watch heart rate sensor during and in recovery from exercise. Twenty-one males completed treadmill exercise while wearing two Apple Watches (left and right wrists) and a Polar S810i monitor (criterion). Exercise involved 5-min bouts of walking, jogging, and running at speeds of 4 km.h−1, 7 km.h−1, and 10 km.h−1, followed by 11 min of rest between bouts. At all exercise intensities the mean bias was trivial. There were very good correlations with the criterion during walking (L: r=0.97; R: r=0.97), but good (L: r=0.93; R: r=0.92) and poor/good (L: r=0.81; R: r=0.86) correlations during jogging and running. Standardised typical error of the estimate was small, moderate, and moderate to large. There were good correlations following walking, but poor correlations following jogging and running. The percentage of heart rates recorded reduced with increasing intensity but increased over time. Intra-device standardised typical errors decreased with intensity. Inter-device standardised typical errors were small to moderate with very good to nearly perfect intraclass correlations. The Apple Watch heart rate sensor has very good validity during walking but validity decreases with increasing intensity.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0043-120195

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Khushhal, A., Nichols, S., Evans, W., Gleadall-Siddall, D., Page, R., O'Doherty, A., Carroll, S., Ingle, L., & Abt, G.
Affiliations
  • University of Hull (GB)
  • Sheffield Hallam University (GB)
  • Northumbria University, Department of Sport, Exercise and Rehabilitation, Newcastle upon Tyne, United Kingdom of Great Britain and Northern Ireland
Corresponding author
Abt, Grant
Venue
Sports Medicine International Open
Published
2017-10
Volume
1
Issue
06
Pages
E206-E211
ISSN
2367-1890 (ISSN-L)
OpenAlex
W2766894515
Cited by
92
References
16
Citations by year
2026: 6 · 2025: 20 · 2024: 16 · 2023: 8 · 2022: 8 · 2021: 11 · 2020: 12 · 2019: 9 · 2018: 1
FWCI
2.71
Type
journal article
Language
en
Open access
Locations
  • Sports Medicine International Open (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Edinburgh Napier Research Repository (Edinburgh Napier University) (publishedVersion, other-oa)
  • Sunderland Repository (University of Sunderland) (acceptedVersion)
  • Repository@Hull (Worktribe) (University of Hull) (submittedVersion, cc-by-nc-nd)
  • Repository@Hull (Worktribe) (University of Hull) (submittedVersion, other-oa)
  • Northumbria Research Link (Northumbria University) (submittedVersion)
  • Research at York St John (York St John University) (submittedVersion)
  • SHURA (Sheffield Hallam University Research Archive) (Sheffield Hallam University) (submittedVersion)
  • Durham Research Online (Durham University) (submittedVersion, cc-by)
  • Open Access Institutional Repository at Robert Gordon University (Robert Gordon University) (submittedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
Apple Watch, heart rate monitoring, wearable sensors, exercise intensity, treadmill exercise, heart rate recovery, measurement validity, measurement reliability, inter-device agreement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review