Pilot study assessing the influence of skin type on the heart rate measurements obtained by photoplethysmography with the Apple Watch

Open access
Sañudo, Borja, De Hoyo, Moisés, Muñoz-López, Alejandro, Perry, John, Abt, Grant·2019·Journal of Medical Systems

Abstract

Photoplethysmographic imaging (PPG) is currently used to measure heart rate (HR) and the accuracy of PPG can be influenced by pigmentation of the skin; however, the effects of skin color-related artifacts on PPG during exercise remain unclear. This study aimed to assess the agreement between the Apple Watch photoplethysmography sensor and a criterion, for measuring heart rate across a range of intensities during exercise and to determine the influence of skin type on the accuracy of the measure. Forty-five males (20-43 y) completed the Fitzpatrick Skin Scale and were classified into three different skin type groups: a) types II (n = 15), III (n = 15) and IV (n = 15). Participants performed a graded incremental cycle-ergometer test while simultaneously wearing the Apple Watch and a Polar monitor as a criterion measure. Data from both devices were collected in 5-s epochs. Correlations between devices were very good (0.96-0.99 [95%CI: 0.94 to 0.99]). Significant differences were observed between skin types II and III when the intensity of the exercise was increased, albeit with trivial to small effect sizes (ES: 0.05 to 0.28). All significant differences corresponded to <2% of relative difference between both devices. Bland-Altman analyses showed a trivial but systematic underestimation of HR in the Apple Watch compared to Polar for all skin types during exercise. In conclusion, the Apple Watch accurately measures HR when cycling at different intensities and certain types of skin seem not to influence these measures, which may have important implications for controlling the intensity of exercise.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10916-019-1325-2

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Reduced accuracy in darker skin tones has been linked to missed detection of atrial fibrillation when irregular pulse notifications fail to capture abnormal rhythms.

    “Reduced accuracy in darker skin tones has been linked to missed detection of atrial fibrillation when irregular pulse notifications fail to capture abnormal rhythms.”

    From Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring (2025) · cites this paper as [7]

    The Results and Discussion (pages unavailable) report no significant Apple Watch heart-rate difference for the darkest skin type studied, type IV; the observed differences were in types II and III. The paper assesses heart-rate measurement during cycling, not atrial-fibrillation detection or irregular-pulse notifications. (LLM, conf=0.84)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • For light skin pigmentation, pulse rate mean bias was -1.24 bpm (95% CI -5.31 to 2.83).

    “Mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for the corresponding groups (Table 4 and Figures 5-7 [41,60-62]).”

    From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [61]

    The Results section (page not available) reports a mean bias of −2 bpm for the lightest skin group studied (type II), with 95% limits of agreement of −8 to 5 bpm. It does not report a bias of −1.24 bpm or a 95% confidence interval of −5.31 to 2.83 bpm; the reported interval is also a different measure. (LLM, conf=0.88)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • For dark skin pigmentation, pulse rate mean bias was -0.57 bpm (95% CI -9.44 to 8.29).

    “Mean biases were –1.24 (95% CI –5.31 to 2.83) bpm, –0.89 (95% CI –3.70 to 1.93) bpm, and –0.57 (95% CI –9.44 to 8.29) bpm for the corresponding groups (Table 4 and Figures 5-7 [41,60-62]).”

    From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [61]

    The Results section (page unavailable) reports a mean bias of −1 bpm for the darkest skin type studied (type IV), with 95% limits of agreement of −6 to 4 bpm. It does not report the claimed −0.57 bpm or a 95% confidence interval of −9.44 to 8.29 bpm; the reported limits of agreement are a different measure from a confidence interval. (LLM, conf=0.88)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • For medium skin pigmentation, pulse rate 95% limits of agreement were -18.62 to 16.84 bpm.

    “Our analysis revealed 95% LoA of –16.02 to 13.54 bpm, –18.62 to 16.84 bpm, and –33.69 to 32.54 bpm for light, medium, and dark skin pigmentation groups, respectively.”

    From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [61]

    The Results section reports 95% limits of agreement of −8 to 4 beats/min for skin type III during exercise, not −18.62 to 16.84 bpm. It reports −5 to 5 beats/min for type III at rest. Our copy does not provide a page number for this passage. (LLM, conf=0.89)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • For dark skin pigmentation, pulse rate 95% limits of agreement were -33.69 to 32.54 bpm.

    “Our analysis revealed 95% LoA of –16.02 to 13.54 bpm, –18.62 to 16.84 bpm, and –33.69 to 32.54 bpm for light, medium, and dark skin pigmentation groups, respectively.”

    From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [61]

    The Results (section 3; page unavailable) report 95% limits of agreement of −6 to 4 bpm for the darkest skin type studied (type IV) during exercise, and −5 to 4 bpm at rest—not −33.69 to 32.54 bpm. The paper also did not include participants with Fitzpatrick skin types V or VI. (LLM, conf=0.90)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Hopkins WG (2016) Validity thresholds and error rates for test measures used to assess individuals. In Proc. 21st Annu. Congress of the European College of Sport Science, Vienna, Austria.

Cited by

Sorted by citations

Authors
Sañudo, B., De Hoyo, M., Muñoz-López, A., Perry, J., & Abt, G.
Affiliations
  • Universidad de Sevilla (ES)
  • Mary Immaculate College (IE)
  • University of Hull (GB)
Corresponding author
Sañudo, Borja
Venue
Journal of Medical Systems
Published
2019-05-22
Volume
43
Issue
7
Pages
195-195
ISSN
  • 0148-5598 (ISSN-L)
  • 1573-689X
OpenAlex
W2945549072
Cited by
48
References
22
Citations by year
2026: 4 · 2025: 10 · 2024: 7 · 2023: 10 · 2022: 7 · 2021: 6 · 2020: 4
FWCI
1.50
Type
journal article
Language
en
Locations
  • Journal of Medical Systems (publishedVersion)
  • PubMed (publishedVersion)
  • Repository@Hull (Worktribe) (University of Hull) (submittedVersion, cc-by)
  • Deposito de Investigacion Universidad de Sevilla (University of Seville) (submittedVersion, other-oa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmography, heart rate measurement, skin pigmentation, Fitzpatrick skin type, Apple Watch, wearable devices, exercise intensity, cycle ergometer test, measurement accuracy
MeSH terms
Wearable Electronic Devices, Adult, Exercise Test, Heart Rate, Humans, Male, Monitoring, Physiologic, Pilot Projects, Skin Pigmentation, Photoplethysmography, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review