A Prospective Study of Indexes Predicting the Outcome of Trials of Weaning from Mechanical Ventilation
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The traditional predictors of the outcome of weaning from mechanical ventilation--minute ventilation (VE) and maximal inspiratory pressure (Plmax)--are frequently inaccurate. We developed two new indexes: the first quantitates rapid shallow breathing as the ratio of respiratory frequency to tidal volume (f/VT), and the second is termed CROP, because it integrates thoracic compliance, respiratory rate, arterial oxygenation, and Plmax. METHODS: The threshold values for each index that discriminated best between a successful and an unsuccessful outcome of weaning were determined in 36 patients, and the predictive accuracy of these values was then tested prospectively in an additional 64 patients. Sensitivity and specificity were calculated, and the data were also analyzed with receiver-operating-characteristic (ROC) curves, in which the proportions of true positive results and false positive results are plotted against each other for a number of threshold values of an index; the area under the curve reflects the accuracy of the index. RESULTS: Sensitivity was highest for Plmax (1.00), followed closely by the f/VT ratio (0.97). Specificity was highest for the f/VT ratio (0.64) and lowest for Plmax (0.11). The f/VT ratio was the best predictor of successful weaning, and Plmax and the f/VT ratio were the best predictors of failure. The area under the ROC curve for the f/VT ratio (0.89) was larger than that under the curves for the CROP index (0.78, P less than 0.05), Plmax (0.61, P less than 0.001), and VE (0.40, P less than 0.001). CONCLUSIONS: Rapid shallow breathing, as reflected by the f/VT ratio, was the most accurate predictor of failure, and its absence the most accurate predictor of success, in weaning patients from mechanical ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Clinical Prediction Rules: Applications and Methodological Standards
Wasson, J. H., Sox, H. C., Neff, R. K., & Goldman, L. (1985) · New England Journal of Medicine · doi:10.1056/nejm198509263131306 · Cited by 1,357
The use of relative operating characteristic (ROC) curves in test performance evaluation.
Beck, & Shultz, E. K. (1986) · PubMed · Cited by 621
Roussos, C. S., & Macklem, P. T. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.43.2.189 · Cited by 497
Respiratory Monitoring in the Intensive Care Unit
Tobin, M. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1625 · Cited by 200
Self-citationCentor, R. M., & Schwartz, J. S. (1985) · Medical Decision Making · doi:10.1177/0272989x8500500204 · Cited by 136
Krieger, B. P., Ershowsky, P., BECKER, D. A., & Gazeroglu, H. (1989) · Critical Care Medicine · doi:10.1097/00003246-198909000-00002 · Cited by 122
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Ely, E. W., Baker, A. M., Dunagan, D. P., Burke, H. L., Smith, A. C., Kelly, P. T., Johnson, M. M., Browder, R. W., Bowton, D. L., & Haponik, E. F. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352502 · Cited by 1,346
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Metadata
- Authors
- Yang, K. L., & Tobin, M. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1991-05-23
- Volume
- 324
- Issue
- 21
- Pages
- 1445-1450
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1993843698
- Cited by
- 1,378
- References
- 8
- FWCI
- 23.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.