A Prospective Study of Indexes Predicting the Outcome of Trials of Weaning from Mechanical Ventilation
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The traditional predictors of the outcome of weaning from mechanical ventilation--minute ventilation (VE) and maximal inspiratory pressure (Plmax)--are frequently inaccurate. We developed two new indexes: the first quantitates rapid shallow breathing as the ratio of respiratory frequency to tidal volume (f/VT), and the second is termed CROP, because it integrates thoracic compliance, respiratory rate, arterial oxygenation, and Plmax. METHODS: The threshold values for each index that discriminated best between a successful and an unsuccessful outcome of weaning were determined in 36 patients, and the predictive accuracy of these values was then tested prospectively in an additional 64 patients. Sensitivity and specificity were calculated, and the data were also analyzed with receiver-operating-characteristic (ROC) curves, in which the proportions of true positive results and false positive results are plotted against each other for a number of threshold values of an index; the area under the curve reflects the accuracy of the index. RESULTS: Sensitivity was highest for Plmax (1.00), followed closely by the f/VT ratio (0.97). Specificity was highest for the f/VT ratio (0.64) and lowest for Plmax (0.11). The f/VT ratio was the best predictor of successful weaning, and Plmax and the f/VT ratio were the best predictors of failure. The area under the ROC curve for the f/VT ratio (0.89) was larger than that under the curves for the CROP index (0.78, P less than 0.05), Plmax (0.61, P less than 0.001), and VE (0.40, P less than 0.001). CONCLUSIONS: Rapid shallow breathing, as reflected by the f/VT ratio, was the most accurate predictor of failure, and its absence the most accurate predictor of success, in weaning patients from mechanical ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Clinical Prediction Rules: Applications and Methodological Standards
Wasson, J. H., Sox, H. C., Neff, R. K., & Goldman, L. (1985) · New England Journal of Medicine · doi:10.1056/nejm198509263131306 · Cited by 1,357
The use of relative operating characteristic (ROC) curves in test performance evaluation.
Beck, & Shultz, E. K. (1986) · PubMed · Cited by 621
Roussos, C. S., & Macklem, P. T. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.43.2.189 · Cited by 497
Respiratory Monitoring in the Intensive Care Unit
Tobin, M. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1625 · Cited by 200
Self-citationCentor, R. M., & Schwartz, J. S. (1985) · Medical Decision Making · doi:10.1177/0272989x8500500204 · Cited by 136
Krieger, B. P., Ershowsky, P., BECKER, D. A., & Gazeroglu, H. (1989) · Critical Care Medicine · doi:10.1097/00003246-198909000-00002 · Cited by 122
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Ely, E. W., Baker, A. M., Dunagan, D. P., Burke, H. L., Smith, A. C., Kelly, P. T., Johnson, M. M., Browder, R. W., Bowton, D. L., & Haponik, E. F. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352502 · Cited by 1,346
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Effect of Failed Extubation on the Outcome of Mechanical Ventilation
Epstein, S. K., Ciubotaru, R. L., & Wong, J. B. (1997) · Chest · doi:10.1378/chest.112.1.186 · Cited by 892
Extubation Outcome after Spontaneous Breathing Trials with T-Tube or Pressure Support Ventilation
ESTEBAN, A., ALÍA, I., GORDO, F., FERNÁNDEZ, R., SOLSONA, J. F., VALLVERDÚ, I., MACÍAS, S., ALLEGUE, J. M., BLANCO, J., CARRIEDO, D., et al. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9610109 · Cited by 795
ESTEBAN, A., ANZUETO, A., ALÍA, I., GORDO, F., APEZTEGUÍA, C., PÁLIZAS, F., CIDE, D., GOLDWASER, R., SOTO, L., BUGEDO, G., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9902018 · Cited by 780
Self-citationESTEBAN, A., ALÍA, I., TOBIN, M. J., GIL, A., GORDO, F., VALLVERDÚ, I., BLANCH, L., BONET, A., VÁZQUEZ, A., de PABLO, R., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9803106 · Cited by 773
Self-citationGosselink, R., Bott, J., Johnson, M., Dean, E., Nava, S., Norrenberg, M., Schönhofer, B., Stiller, K., van de Leur, H., & Vincent, J. L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1026-7 · Cited by 751
Slutsky, A. S. (1993) · Chest · doi:10.1378/chest.104.6.1833 · Cited by 563
Diaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*
Kim, W. Y., Suh, H. J., Hong, S.-B., Koh, Y., & Lim, C.-M. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182266408 · Cited by 550
Implications of Extubation Delay in Brain-Injured Patients Meeting Standard Weaning Criteria
COPLIN, W. M., PIERSON, D. J., COOLEY, K. D., NEWELL, D. W., & RUBENFELD, G. D. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9905102 · Cited by 544
Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2014) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 487
VALLVERDÚ, I., CALAF, N., SUBIRANA, M., NET, A., BENITO, S., & MANCEBO, J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9712135 · Cited by 480
Advances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
Self-citationKhamiees, M., Raju, P., DeGirolamo, A., Amoateng-Adjepong, Y., & Manthous, C. A. (2001) · Chest · doi:10.1378/chest.120.4.1262 · Cited by 466
BTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults
Davidson, A. C., Banham, S., Elliott, M., Kennedy, D., Gelder, C., Glossop, A., Church, A. C., Creagh-Brown, B., Dodd, J. W., Felton, T., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-208209 · Cited by 426
Predicting Success in Weaning From Mechanical Ventilation
Meade, M., Guyatt, G., Cook, D., Griffith, L., Sinuff, T., Kergl, C., Mancebo, J., Esteban, A., & Epstein, S. (2001) · Chest · doi:10.1378/chest.120.6_suppl.400s · Cited by 424
Grubin, C. E., Daniels, T., Toivola, B., Landin-Olsson, M., Hagopian, W. A., Li, L., Karlsen, A. E., Boel, E., Michelsen, B., & Lernmark, �. (1994) · Diabetologia · doi:10.1007/bf00408469 · Cited by 415
“use of GAD65 [7, 21] and GAD67 [10] cDNA to synthesize by in vitro translation and transcription specific radioactive ligands used in a radioimmunoassay of GAD65 and GAD67 antibodies and the use of the ROC plot [ 22-25 ] to determine the diagnostic accuracy of the GAD antibody test.”
MethodRisk Factors for Extubation Failure in Patients Following a Successful Spontaneous Breathing Trial
Frutos-Vivar, F., Ferguson, N. D., Esteban, A., Epstein, S. K., Arabi, Y., Apezteguía, C., González, M., Hill, N. S., Nava, S., D’Empaire, G., et al. (2006) · Chest · doi:10.1378/chest.130.6.1664 · Cited by 406
GIRAULT, C., DAUDENTHUN, I., CHEVRON, V., TAMION, F., LEROY, J., & BONMARCHAND, G. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.1.9802120 · Cited by 365
Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1246oc · Cited by 359
Self-citationPredictors of Successful Extubation in Neurosurgical Patients
NAMEN, A. M., WESLEY ELY, E., TATTER, S. B., DOUGLAS CASE, L., LUCIA, M. A., SMITH, A., LANDRY, S., WILSON, J. A., GLAZIER, S. S., BRANCH, C. L., et al. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2003060 · Cited by 355
Basing Respiratory Management of COVID-19 on Physiological Principles
Tobin, M. J. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202004-1076ed · Cited by 330
Self-citationWeaning and extubation readiness in pediatric patients*
Newth, C. J. L., Venkataraman, S., Willson, D. F., Meert, K. L., Harrison, R., Dean, J. M., Pollack, M., Zimmerman, J., Anand, K. J. S., Carcillo, J. A., et al. (2009) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e318193724d · Cited by 328
Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014) · Critical Ultrasound Journal · doi:10.1186/2036-7902-6-8 · Cited by 306
Large Scale Implementation of a Respiratory Therapist– driven Protocol for Ventilator Weaning
ELY, E. W., BENNETT, P. A., BOWTON, D. L., MURPHY, S. M., FLORANCE, A. M., & HAPONIK, E. F. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9805120 · Cited by 304
VASSILAKOPOULOS, T., ZAKYNTHINOS, S., & ROUSSOS, C. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.2.9710084 · Cited by 297
Martin, A. D., Smith, B. K., Davenport, P. D., Harman, E., Gonzalez-Rothi, R. J., Baz, M., Layon, A. J., Banner, M. J., Caruso, L. J., Deoghare, H., et al. (2011) · Critical Care · doi:10.1186/cc10081 · Cited by 294
Weaning Patients from the Ventilator
McConville, J. F., & Kress, J. P. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1203367 · Cited by 270
Tobin, M. J. (1994) · New England Journal of Medicine · doi:10.1056/nejm199404143301507 · Cited by 262
Self-citationAssociation Between Reduced Cuff Leak Volume and Postextubation Stridor
Miller, R. L., & Cole, R. P. (1996) · Chest · doi:10.1378/chest.110.4.1035 · Cited by 260
Predicting the Duration of Mechanical Ventilation
Seneff, M. G., Zimmerman, J. E., Knaus, W. A., Wagner, D. P., & Draper, E. A. (1996) · Chest · doi:10.1378/chest.110.2.469 · Cited by 231
Intrinsic positive end-expiratory pressure (PEEPi)
Rossi, A., Polese, G., Brandi, G., & Conti, G. (1995) · Intensive Care Medicine · doi:10.1007/bf01706208 · Cited by 228
Artificial Intelligence and Machine Learning in Anesthesiology
Connor, C. W. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002694 · Cited by 227
Clinical review: The ABC of weaning failure - a structured approach
Heunks, L. M., & van der Hoeven, J. G. (2010) · Critical Care · doi:10.1186/cc9296 · Cited by 220
Hepatopulmonary syndrome in candidates for liver transplantation
Martı́nez, G. P., Barberà, J. A., Visa, J., Rimola, A., Paré, J. C., Roca, J., Navasa, M., Rodés, J., & Rodriguez-Roisin, R. (2001) · Journal of Hepatology · doi:10.1016/s0168-8278(00)00108-2 · Cited by 211
Diaphragm Dysfunction in Critical Illness
Supinski, G. S., Morris, P. E., Dhar, S., & Callahan, L. A. (2018) · Chest · doi:10.1016/j.chest.2017.08.1157 · Cited by 211
Rapid Shallow Breathing (Frequency-Tidal Volume Ratio) Did Not Predict Extubation Outcome
Lee, K. H., Hui, K. P., Chan, T. B., Tan, W. C., & Lim, T. K. (1994) · Chest · doi:10.1378/chest.105.2.540 · Cited by 208
Physiologic Determinants of Ventilator Dependence in Long-term Mechanically Ventilated Patients
PURRO, A., APPENDINI, L., DE GAETANO, A., GUDJONSDOTTIR, M., DONNER, C. F., & ROSSI, A. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.4.9812160 · Cited by 189
Diagnostic methods to assess inspiratory and expiratory muscle strength
Caruso, P., Albuquerque, A. L. P. D., Santana, P. V., Cardenas, L. Z., Ferreira, J. G., Prina, E., Trevizan, P. F., Pereira, M. C., Iamonti, V., Pletsch, R., et al. (2015) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132015000004474 · Cited by 179
Impact of whole-body rehabilitation in patients receiving chronic mechanical ventilation
Martin, U. J., Hincapie, L., Nimchuk, M., Gaughan, J., & Criner, G. J. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000181730.02238.9b · Cited by 177
Effects of obesity on breathing pattern, ventilatory neural drive and mechanics
Chlif, M., Keochkerian, D., Choquet, D., Vaidie, A., & Ahmaidi, S. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.06.012 · Cited by 173
Partial Liquid Ventilation in Adult Patients with Acute Respiratory Distress Syndrome
Kacmarek, R. M., Wiedemann, H. P., Lavin, P. T., Wedel, M. K., Tütüncü, A. S., & Slutsky, A. S. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200508-1196oc · Cited by 171
Titration and Implementation of Neurally Adjusted Ventilatory Assist in Critically Ill Patients
Brander, L., Leong-Poi, H., Beck, J., Brunet, F., Hutchison, S. J., Slutsky, A. S., & Sinderby, C. (2009) · Chest · doi:10.1378/chest.08-1747 · Cited by 171
Nasal highflow improves ventilation in patients with COPD
Bräunlich, J., Köhler, M., & Wirtz, H. (2016) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s104616 · Cited by 165
Spadaro, S., Grasso, S., Mauri, T., Dalla Corte, F., Alvisi, V., Ragazzi, R., Cricca, V., Biondi, G., Di Mussi, R., Marangoni, E., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1479-y · Cited by 163
Mechanical Ventilation Antioxidant Trial
Howe, K. P., Clochesy, J. M., Goldstein, L. S., & Owen, H. (2015) · American Journal of Critical Care · doi:10.4037/ajcc2015335 · Cited by 52
Vidotto, M. C., Sogame, L. C. M., Calciolari, C. C., Nascimento, O. A., & Jardim, J. R. (2008) · Neurocritical Care · doi:10.1007/s12028-008-9059-x · Cited by 47
“Yang and Tobin [ 12 ], first described that a value of 105 or over for the f/Vt ratio would predict unsuccessful extubation.”
BackgroundInfluentialGao, Y., Xu, A., Hu, P. J.-H., & Cheng, T.-H. (2017) · Decision Support Systems · doi:10.1016/j.dss.2017.01.007 · Cited by 26
ClinicalVis: Supporting Clinical Task-Focused Design Evaluation
Ghassemi, M., Pushkarna, M., Wexler, J., Johnson, J., & Varghese, P. (2018) · arXiv · doi:10.48550/arxiv.1810.05798 · Cited by 26
Liu, W., Tao, G., Zhang, Y., Xiao, W., Zhang, J., Liu, Y., Lu, Z., Hua, T., & Yang, M. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2021.814566 · Cited by 25
“Unfortunately, the accuracy of these factors in predicting weaning is unsatisfactory (10, 11).”
BackgroundMethod
Metadata
- Authors
- Yang, K. L., & Tobin, M. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1991-05-23
- Volume
- 324
- Issue
- 21
- Pages
- 1445-1450
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W1993843698
- Cited by
- 1,378
- References
- 8
- FWCI
- 23.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.