Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular Arrhythmia
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Unsustained ventricular tachycardia in patients with previous myocardial infarction and left ventricular dysfunction is associated with a two-year mortality rate of about 30 percent. We studied whether prophylactic therapy with an implanted cardioverter-defibrillator, as compared with conventional medical therapy, would improve survival in this high-risk group of patients. METHODS: Over the course of five years, 196 patients in New York Heart Association functional class I, II, or III with prior myocardial infarction; a left ventricular ejection fraction < or = 0.35; a documented episode of asymptomatic unsustained ventricular tachycardia; and inducible, nonsuppressible ventricular tachyarrhythmia on electrophysiologic study were randomly assigned to receive an implanted defibrillator (n = 95) or conventional medical therapy (n=101). We used a two-sided sequential design with death from any cause as the end point. RESULTS: The base-line characteristics of the two treatment groups were similar. During an average follow-up of 27 months, there were 15 deaths in the defibrillator group (11 from cardiac causes) and 39 deaths in the conventional-therapy group (27 from cardiac causes) (hazard ratio for overall mortality, 0.46; 95 percent confidence interval, 0.26 to 0.82; P=0.009). There was no evidence that amiodarone, beta-blockers, or any other antiarrhythmic therapy had a significant influence on the observed hazard ratio. CONCLUSIONS: In patients with a prior myocardial infarction who are at high risk for ventricular tachyarrhythmia, prophylactic therapy with an implanted defibrillator leads to improved survival as compared with conventional medical therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“NSVT accompanied by inducibility of sustained VT during programmed ventricular stimulation was associated with an increased risk of SCD”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Moss et al., 1996
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Echt, D. S., Liebson, P. R., Mitchell, L. B., Peters, R. W., Obias-Manno, D., Barker, A. H., Arensberg, D., Baker, A., Friedman, L., Greene, H. L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241201 · Cited by 3,253
Mirowski, M., Reid, P. R., Mower, M. M., Watkins, L., Gott, V. L., Schauble, J. F., Langer, A., Heilman, M. S., Kolenik, S. A., Fischell, R. E., et al. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008073030607 · Cited by 1,361
Bigger, J. T., Fleiss, J. L., Kleiger, R., Miller, J. P., & Rolnitzky, L. M. (1984) · Circulation · doi:10.1161/01.cir.69.2.250 · Cited by 1,286
Amiodarone in Patients with Congestive Heart Failure and Asymptomatic Ventricular Arrhythmia
Singh, S. N., Fletcher, R. D., Fisher, S. G., Singh, B. N., Lewis, H. D., Deedwania, P. C., Massie, B. M., Colling, C., & Lazzeri, D. (1995) · New England Journal of Medicine · doi:10.1056/nejm199507133330201 · Cited by 1,225
Long-term outcome with the automatic implantable cardioverter-defibrillator
Winkle, R. A., Mead, R. H., Ruder, M. A., Gaudiani, V. A., Smith, N. A., Buch, W. S., Schmidt, P., & Shipman, T. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90310-0 · Cited by 719
Clinical classification of cardiac deaths.
Hinkle, L. E., & Thaler, H. T. (1982) · Circulation · doi:10.1161/01.cir.65.3.457 · Cited by 638
A Comparison of Seven Antiarrhythmic Drugs in Patients with Ventricular Tachyarrhythmias
Mason, J. W. (1993) · New England Journal of Medicine · doi:10.1056/nejm199308123290702 · Cited by 462
Echt, D. S., Armstrong, K., Schmidt, P., Oyer, P. E., Stinson, E. B., & Winkle, R. A. (1985) · Circulation · doi:10.1161/01.cir.71.2.289 · Cited by 452
Cited by
Items 401–500 of 1,004
Is defibrillation testing required for defibrillator implantation?
Strickberger, S. A., & Klein, G. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.068 · Cited by 95
Eckert, M., & Jones, T. (2002) · International Journal of Nursing Practice · doi:10.1046/j.1440-172x.2002.00357.x · Cited by 94
Chan, P. S., Nallamothu, B. K., Spertus, J. A., Masoudi, F. A., Bartone, C. L., Kereiakes, D. J., & Chow, T. (2009) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.108.807123 · Cited by 94
Task force members, Vijgen, J., Botto, G., Camm, J., Hoijer, C.-J., Jung, W., Le Heuzey, J.-Y., Lubinski, A., Norekval, T. M., Santomauro, M., et al. (2009) · Europace · doi:10.1093/europace/eup112 · Cited by 98
Leitlinien zur Implantation von Defibrillatoren
Hohnloser, S. H., Andresen, D., Block, M. S., Breithardt, G., Jung, W., Klein, H. H., Kuck, K. H., Lüderitz, B., & Steinbeck, G. (2001) · Steinkopff eBooks · doi:10.1007/978-3-642-57631-7_8 · Cited by 94
Self-citationJacq, F., Fouldrin, G., Savouré, A., Anselme, F., Baguelin-Pinaud, A., Cribier, A. G., & Thibaut, F. (2009) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2009.01.003 · Cited by 104
Goldberger, J. J., CAIN, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., PASSMAN, R. S., Siscovick, D. S., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.05.031 · Cited by 97
Beggs, S. A. S., Jhund, P. S., Jackson, C. E., McMurray, J. J. V., & Gardner, R. S. (2018) · Heart · doi:10.1136/heartjnl-2016-310850 · Cited by 90
Sudden cardiac death in dialysis patients: different causes and management strategies
Genovesi, S., Boriani, G., Covic, A. C., Vernooij, R. W. M., Combe, C., Burlacu, A., Davenport, A., Kanbay, M., Kirmizis, D. A., Schneditz, D., et al. (2019) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfz182 · Cited by 95
Risk stratification of sudden cardiac death: a review
Tfelt‐Hansen, J., Garcia, R., Albert, C. M., Merino, J. L., Krahn, A. D., Marijon, É., Basso, C., Wilde, A. A. M., & Haugaa, K. H. (2023) · EP Europace · doi:10.1093/europace/euad203 · Cited by 99
“In addition, initial trials on SCD primary prevention included PES for risk stratification of high-risk patients with LVEF < 35–40%.(53,54) However, subsequent trials showed that the risk was already high enough in patients with LVEF < 30 or 35% to warrant ICD implantation without further PES stratification.”
BackgroundSudden Death in Patients With Cardiac Implantable Electronic Devices
Tseng, Z. H., Hayward, R. M., Clark, N. M., Mulvanny, C. G., Colburn, B., Ursell, P. C., Olgin, J. E., Hart, A. P., & Moffatt, E. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.2641 · Cited by 92
Advances in Echocardiographic Imaging in Heart Failure With Reduced and Preserved Ejection Fraction
Omar, A. M. S., Bansal, M., & Sengupta, P. P. (2016) · Circulation Research · doi:10.1161/circresaha.116.309128 · Cited by 103
Salukhe, T. V., Francis, D. P., & Sutton, R. (2003) · International Journal of Cardiology · doi:10.1016/s0167-5273(02)00585-5 · Cited by 91
Meta-Analysis of Mortality in Dialysis Patients With an Implantable Cardioverter Defibrillator
Sakhuja, R., Keebler, M., Lai, T., McLaughlin-Gavin, C., Thakur, R. K., & Bhatt, D. L. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.11.014 · Cited by 90
Russo, A. M., Daugherty, S. L., Masoudi, F. A., Wang, Y., Curtis, J. P., & Lampert, R. J. (2015) · American Heart Journal · doi:10.1016/j.ahj.2015.02.025 · Cited by 90
Moss, A. J., Fadl, Y. Y., Zaręba, W., Cannom, D. S., & Hall, W. J. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01729-5 · Cited by 90
Self-citationSudden Death in Heart Failure: Vascular or Electrical?
Cleland, J. G. F., Massie, B. M., & Packer, M. (1999) · European Journal of Heart Failure · doi:10.1016/s1388-9842(99)00009-4 · Cited by 93
On Estimating Medical Cost and Incremental Cost-Effectiveness Ratios with Censored Data
Zhao, H., & Tian, L. (2001) · Biometrics · doi:10.1111/j.0006-341x.2001.01002.x · Cited by 90
Auricchio, A., Klein, H., Geller, J. C., Reek, S., Heilman, M. S., & Szymkiewicz, S. J. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00120-9 · Cited by 89
Self-citationMaron, B. J., Rowin, E. J., & Maron, M. S. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.01.019 · Cited by 93
Milliez, P., Messaoudi, S., Nehmé, J., Rodriguez, C., Samuel, J., & Delcayre, C. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00591.2008 · Cited by 89
Implantable Defibrillators and Prevention of Sudden Death in Hypertrophic Cardiomyopathy
MARON, B. J., & SPIRITO, P. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01147.x · Cited by 90
Stevens, S. M., Reinier, K., & Chugh, S. S. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.974931 · Cited by 99
Grimm, W., Hoffmann, J. Ü., Müller, H., & Maisch, B. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01822-8 · Cited by 92
Ventricular arrhythmias. Ventricular tachycardias and sudden cardiac death. 2020 Clinical guidelines
Lebedev, D. S., Mikhaylov, E. N., Neminuschiy, N. M., Golukhova, E. Z., Babokin, V. E., Bereznitskaya, V. V., Vasichkina, E. S., Garkina, S. V., Sp, G., Davtyan, K. V., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4600 · Cited by 96
Sudden Cardiac Death: Epidemiology, Mechanisms, and Therapy
Turakhia, M. P., & Tseng, Z. H. (2007) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2007.05.002 · Cited by 100
Gulizia, M. M., Piraino, L., Scherillo, M., Puntrello, C., Vasco, C., Scianaro, M. C., Mascia, F., Pensabene, O., Giglia, S., Chiarandà, G., et al. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.804211 · Cited by 92
SEARS, S. F., BURNS, J. L., HANDBERG, E., SOTILE, W. M., & CONTI, J. B. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.01113.x · Cited by 85
van der Heijden, A. C., Borleffs, C. J. W., Buiten, M. S., Thijssen, J., van Rees, J. B., Cannegieter, S. C., Schalij, M. J., & van Erven, L. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.02.035 · Cited by 87
Implantable cardioverter-defibrillator deactivation at the end of life: A physician survey
Kelley, A. S., Reid, M. C., Miller, D. H., Fins, J. J., & Lachs, M. S. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.12.011 · Cited by 92
Cost-effectiveness of heart failure therapies
Rohde, L. E. P., Bertoldi, E. G., Goldraich, L. A., & Polanczyk, C. A. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.60 · Cited by 98
Ischaemic heart disease presenting as arrhythmias
Ghuran, A., & Camm, A. J. (2001) · British Medical Bulletin · doi:10.1093/bmb/59.1.193 · Cited by 102
Hulleman, M., Berdowski, J., de Groot, J. R., van Dessel, P. F. H. M., Borleffs, C. J. W., Blom, M. T., Bardai, A., de Cock, C. C., Tan, H. L., Tijssen, J. G. P., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.089425 · Cited by 85
Tjong, F. V. Y., Brouwer, T. F., Koop, B. E., Soltis, B., Shuros, A. C., Schmidt, B. L., Swackhamer, B., Quast, A. B. E., Wilde, A. A. M., Burke, M. C., et al. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.04.002 · Cited by 88
Clinical relevance of arrhythmias during sleep: guidance for clinicians
Gula, L. J., Krahn, A. D., Skanes, A. C., Yee, R. K., & Klein, G. J. (2004) · Heart · doi:10.1136/hrt.2003.019323 · Cited by 85
Bunch, T. J., Hohnloser, S. H., & Gersh, B. J. (2007) · Circulation · doi:10.1161/circulationaha.106.683235 · Cited by 99
Shedd, O. L., Sears, S. F., Harvill, J. L., Arshad, A., CONTI, J. B., Steinberg, J. S., & Curtis, A. B. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.058 · Cited by 85
Cowie, M. R., Marshall, D., Drummond, M., Ferko, N., Maschio, M., Ekman, M., de Roy, L., Heidbuchel, H., Verboven, Y., Braunschweig, F., et al. (2009) · EP Europace · doi:10.1093/europace/eup068 · Cited by 85
Godemann, F., Butter, C., Lampe, F., Linden, M., Schlegl, M., Schultheiss, H., & Behrens, S. (2004) · Clinical Cardiology · doi:10.1002/clc.4960270604 · Cited by 85
Reek, S., Geller, J. C., Meltendorf, U., WOLLBRUECK, A., Szymkiewicz, S. J., & Klein, H. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00311.x · Cited by 84
“(4) The gel is released and the device tries for 3 seconds to synchronize the shock.”
BackgroundSelf-citationBarra, S., Providencia, R. A., Paiva, L., Heck, P. M., & Agarwal, S. (2014) · EP Europace · doi:10.1093/europace/euu296 · Cited by 92
“Average age of patients at the time of study enrolment was between 58–65 years in secondary prevention trials(3) – 5 and 58–66 years in the primary prevention trials.(1,2,6,7) Less than 25% of subjects included in the major clinical ICD trials are estimated to be .”
BackgroundCardiac contractility modulation: a novel approach for the treatment of heart failure
ABI‐SAMRA, F. M., & Gutterman, D. D. (2016) · Heart Failure Reviews · doi:10.1007/s10741-016-9571-6 · Cited by 92
Disparities in the Use of Primary Prevention and Defibrillator Therapy Among Blacks and Women
Gauri, A. J., Davis, A. M., Hong, T. E., Burke, M. C., & Knight, B. P. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.08.021 · Cited by 84
Implantable cardioverter defibrillator (ICD) in children
Eicken, A., Kolb, C., Lange, S., Brodherr-Heberlein, S., Zrenner, B., Schreiber, C., & Hess, J. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.02.048 · Cited by 91
“, in patients at risk for but not having had a serious ventricular arrhythmia) [5–7] and for secondary prevention (after successful resuscitation from a life-threatening arrhythmia) [2–4].”
BackgroundClinical Management and Prevention of Sudden Cardiac Death
Yousuf, O. K., Chrispin, J., Tomaselli, G. F., & Berger, R. D. (2015) · Circulation Research · doi:10.1161/circresaha.116.304555 · Cited by 93
Rigolli, M., Anandabaskaran, S., Christiansen, J., & WHALLEY, G. A. (2016) · Open Heart · doi:10.1136/openhrt-2015-000388 · Cited by 88
Short-Term Exposure to Air Pollution and Cardiac Arrhythmia: A Meta-Analysis and Systematic Review
Song, X., Liu, Y., Hu, Y., Zhao, X., Tian, J., Ding, G., & Wang, S. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13070642 · Cited by 93
Boyé, P., Abdel‐Aty, H., Zacharzowsky, U. B., Bohl, S., Schwenke, C., van der Geest, R. J., Dietz, R., Schirdewan, A., & Schulz‐Menger, J. (2011) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2011.04.014 · Cited by 82
Borleffs, C. J. W., Thijssen, J., de Bie, M. K., van Rees, J. B., van Welsenes, G. H., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02780.x · Cited by 82
Infection and mortality after implantation of a subcutaneous ICD after transvenous ICD extraction
Boersma, L. V. A., Burke, M. C., Neužil, P., Lambiase, P. D., Friehling, T. D., Theuns, D. A. M. J., Garcia, F. C., Carter, N., Stivland, T. M., & Weiss, R. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.08.039 · Cited by 82
Obstructive sleep apnea syndrome
Litvin, A. Y., & Chazova, I. E. (2009) · Systemic Hypertension · doi:10.26442/sg28846 · Cited by 82
Sanguinetti, M. C. (2009) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-009-0758-8 · Cited by 97
Ørn, S., Cleland, J. G. F., Romo, M., KJEKSHUS, J. K., & Dickstein, K. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.02.010 · Cited by 84
Jayatilleke, I., Doolan, A., Ingles, J., McGuire, M. A., Booth, V., Richmond, D., & Semsarian, C. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.01.057 · Cited by 82
Godemann, F., Butter, C., Lampe, F., Linden, M., Werner, S., & Behrens, S. (2004) · Quality of Life Research · doi:10.1023/b:qure.0000018493.32844.56 · Cited by 81
“The evaluation of medical treatments is primarily focused on outcome variables like morbidity and mortality [1, 2].”
BackgroundCardiac device infections are associated with a significant mortality risk
de Bie, M. K., van Rees, J. B., Thijssen, J., Borleffs, C. J. W., Trines, S. A. I. P., Cannegieter, S. C., Schalij, M. J., & van Erven, L. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.10.034 · Cited by 82
Survival in octogenarians receiving implantable defibrillators
Koplan, B. A., Epstein, L. M., Albert, C. M., & Stevenson, W. G. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.06.008 · Cited by 85
Theuns, D. A. M. J., Rivero‐Ayerza, M., Boersma, E., & Jordaens, L. J. L. M. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.041 · Cited by 87
Visualization of Fibroblast Activation After Myocardial Infarction Using 68Ga-FAPI PET
Kessler, L., Kupusović, J., Ferdinandus, J., Hirmas, N., Umutlu, L., Zarrad, F., Nader, M., Fendler, W. P., Totzeck, M., Wakili, R., et al. (2021) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000003745 · Cited by 80
Zaman, S. J., Sivagangabalan, G., Narayan, A., Thiagalingam, A., Ross, D. L., & Kovoor, P. (2009) · Circulation · doi:10.1161/circulationaha.108.836791 · Cited by 82
Isaksen, K., Morken, I. M., Munk, P. S., & Larsen, A. I. (2011) · European Journal of Preventive Cardiology · doi:10.1177/1741826711414624 · Cited by 82
Hauer, R. N. W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2584 · Cited by 80
Not Everyone With an Ejection Fraction ≤30% Should Receive an ICD
Buxton, A. E. (2005) · Circulation · doi:10.1161/01.cir.0000165057.88551.2c · Cited by 86
Thomas, K. L., Al‐Khatib, S. M., Kelsey, R. C., Bush, H., Brosius, L., Velazquez, E. J., Peterson, E. D., & Gilliam, F. R. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.04.024 · Cited by 79
Curtis, A. B., Ellenbogen, K. A., Hammill, S. C., Hayes, D. L., REYNOLDS, D. W., Wilber, D. J., & CAIN, M. E. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.08.003 · Cited by 79
Self-citationEffect of risk stratification on cost-effectiveness of the implantable cardioverter defibrillator
Owens, D. K., Sanders, G. D., Heidenreich, P. A., McDonald, K. M., & Hlatky, M. A. (2002) · American Heart Journal · doi:10.1067/mhj.2002.125501 · Cited by 83
Böcker, D., Bänsch, D., Heinecke, A., Weber, M., Brunn, J., Hammel, D., Borggrefe, M., Breithardt, G., & Block, M. S. (1998) · Circulation · doi:10.1161/01.cir.98.16.1636 · Cited by 79
Haugaa, K. H., Tilz, R. R., Bovéda, S., Dobreanu, D., Sciaraffia, E., Mansourati, J., Papiashvili, G., & Dagres, N. (2017) · EP Europace · doi:10.1093/europace/eux089 · Cited by 81
Mazurek, J. A., & Jessup, M. L. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2015.08.001 · Cited by 81
Sanders, G. D., Hlatky, M. A., Every, N. R., McDonald, K. M., Heidenreich, P. A., Parsons, L. S., & Owens, D. K. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-10-200111200-00007 · Cited by 86
“Recent studies of the implantable cardioverter defibrillator (ICD) in patients who have no history of sustained arrhythmia have also had mixed results, with positive results in patients with unsustained ventricular tachycardia (11, 12) and negative results in patients with reduced ejection fraction and positive result…”
BackgroundResultColquitt, J. L., Mendes, D., Clegg, A. J., Harris, P., Cooper, K., Picot, J., & Bryant, J. (2014) · Health Technology Assessment · doi:10.3310/hta18560 · Cited by 74
“Other non-device-specific adverse events were reported by four trials.(75,82,90,99) In the MADIT I(99) and SCD-HeFT(75) trials only syncope (5%) and hypothyroidism (6%) affected ≥ 5% of people in the comparator groups.”
BackgroundMethodInfluentialProietti, R., Labos, C., Davis, M., Thanassoulis, G., Santangeli, P., Russo, V., Biase, L. D., Roux, J.-F., Verma, A., Natale, A., et al. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.11.023 · Cited by 84
Predictors of VT/VF-occurrence in ICD patients: results from the PROFIT-Study
Klein, G. G., Lissel, C., Fuchs, A.-C., Gardiwal, A., Oswald, H., deSousa, M., Pichlmaier, A. M., Lichtinghagen, R., Geerlings, H., Lippolt, P., et al. (2006) · EP Europace · doi:10.1093/europace/eul082 · Cited by 81
Providencia, R. A., Kramer, D. B., Pimenta, D., Babu, G. G., Hatfield, L. A., Ioannou, A., Novak, J., Hauser, R. G., & Lambiase, P. D. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.002418 · Cited by 77
Buxton, A. E., Sweeney, M. O., Wathen, M. S., Josephson, M. E., Otterness, M. F., Hogan-Miller, E., Stark, A. J., & DeGroot, P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.060 · Cited by 77
“001* Atrial tachycardia 2 (1) 4 (2) 0.”
Korean Guidelines for Diagnosis and Management of Chronic Heart Failure
Kim, M., Lee, J., Kim, E. J., Park, D.-G., Park, S., Park, J. J., Shin, M., Yoo, B., Youn, J., Lee, S. E., et al. (2017) · Korean Circulation Journal · doi:10.4070/kcj.2017.0009 · Cited by 81
Prognostic Importance of Atrial Fibrillation in Implantable Cardioverter-Defibrillator Patients
Borleffs, C. J. W., van Rees, J. B., van Welsenes, G. H., van der Velde, E. T., van Erven, L., Bax, J. J., & Schalij, M. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.053 · Cited by 85
Bello, D. B., Einhorn, A., Kaushal, R., Kenchaiah, S., Raney, A. R., Fieno, D. S., Narula, J., Goldberger, J. J., Shivkumar, K., Subacius, H. P., et al. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.03.031 · Cited by 76
Goldstein, N. E., & Lynn, J. (2006) · Perspectives in biology and medicine · doi:10.1353/pbm.2006.0008 · Cited by 83
“…due to better medication regimens and improvements such as ICDs, ventricular assist devices, artificial hearts, and cardiac transplants (Bardy et al. 2005; Bristow et al. 2004; Buxton et al. 1993; Copeland et al. 2004; Kadish et al. 2004; Moss et al. 1996; Moss et al. 2002; Stevenson et al. 2004).”
BackgroundModern Management of Acute Myocardial Infarction
Yang, E. H., Brilakis, E. S., Reeder, G. S., & Gersh, B. J. (2006) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2006.08.004 · Cited by 87
Mazurek, J. A., & Jessup, M. L. (2016) · Heart Failure Clinics · doi:10.1016/j.hfc.2016.07.001 · Cited by 96
Multicenter Automatic Defibrillator Implantation Trial II (MADIT II): Design and Clinical Protocol
Moss, A. J., Cannom, D. S., Daubert, J. P., Hall, W. J., Higgins, S. L., Klein, H., Wilber, D. J., Zaręba, W., Brown, M. W., & MADIT II Investigators (1999) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1999.tb00369.x · Cited by 76
Self-citationSafety and Efficacy of the Subcutaneous Implantable Defibrillator
Lewis, G. F., & Gold, M. R. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.11.026 · Cited by 76
Sjöblom, J., Muhrbeck, J., Witt, N., Alam, M., & Frykman, V. (2014) · Circulation · doi:10.1161/circulationaha.114.009924 · Cited by 78
Steinberg, J. S., Martins, J. B., Sadanandan, S., Goldner, B. G., Menchavez, E., DOMANSKI, M. J., Russo, A. M., Tullo, N. G., & Hallstrom, A. (2001) · American Heart Journal · doi:10.1067/mhj.2001.117129 · Cited by 82
Cygankiewicz, I., Gillespie, J. A., Zaręba, W., Brown, M. W., Goldenberg, I., Klein, H., McNitt, S. A., Polonsky, S., Andrews, M. L., Dwyer, E. M., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.12.023 · Cited by 81
Self-citationQuality of Life in Patients with an Implantable Cardioverter Defibrillator: A Systematic Review
Tomzik, J., Koltermann, K. C., Zabel, M., Willich, S. N., & Reinhold, T. (2015) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2015.00034 · Cited by 84
Epstein, A. E., Baessler, C. A., Curtis, A. B., Estes, N. A. M., Gersh, B. J., Grubb, B., & Mitchell, L. B. (2007) · Circulation · doi:10.1161/circulationaha.106.180203 · Cited by 75
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Cheitlin, M. D. (2010) · Yearbook of Cardiology · doi:10.1016/s0145-4145(10)79851-8 · Cited by 74
Autonomic markers and prediction of cardiac death after myocardial infarction
Barron, H. V., & Viskin, S. (1998) · The Lancet · doi:10.1016/s0140-6736(05)78676-1 · Cited by 77
Complications of Third‐Generation Implantable Cardioverter Defibrillator Therapy
Grimm, W., Menz, V., Hoffmann, J., Timmann, U., FUNCK, R. C., Moosdorf, R., & Maisch, B. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00334.x · Cited by 74
Lee, K. L., Hafley, G. E., Fisher, J. D., Gold, M. R., Prystowsky, E. N., Talajic, M. R., Josephson, M. E., Packer, D. L., & Buxton, A. E. (2002) · Circulation · doi:10.1161/01.cir.0000021920.73149.c3 · Cited by 74
Ghezzi, E. S., Sharman, R. L. S., Selvanayagam, J. B., Psaltis, P. J., Sanders, P., Astley, J. M., Knayfati, S., Batra, V., & Keage, H. A. D. (2023) · Europace · doi:10.1093/europace/euad130 · Cited by 73
Groh, W. J., Bhakta, D., Tomaselli, G. F., Aleong, R. G., Teixeira, R. A., Amato, A. A., Asirvatham, S. J., Cha, Y., Corrado, D., Duboc, D., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.04.022 · Cited by 78
Kloppe, A., Proclemer, A., Arenal, Á., Lunati, M., Ferrer, J. M., Hersi, A. S., Gułaj, M., WIJFFELS, M. C. E. F., Santi, E., Manotta, L., et al. (2014) · Circulation · doi:10.1161/circulationaha.114.009468 · Cited by 73
Robin, J. C., Weinberg, K. M., Tiongson, J. E., Carnethon, M. R., Reddy, M., Ciaccio, C. E., Quadrini, M., Hsu, J. C., Fan, J. S., Choi, P., et al. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.06.013 · Cited by 73
Life-Years Gained From Defibrillator Implantation
Salukhe, T. V., Dimopoulos, K., Sutton, R., Coats, A. J. S., Piepoli, M. F., & Francis, D. P. (2004) · Circulation · doi:10.1161/01.cir.0000125522.10053.29 · Cited by 73
Effect of β-Blocking Therapy on Outcome in the Multicenter UnSustained Tachycardia Trial (MUSTT)
Ellison, K., Hafley, G. E., Hickey, K. T., Kellen, J., Coromilas, J., Steín, K. M., Lee, K. L., & Buxton, A. E. (2002) · Circulation · doi:10.1161/01.cir.0000038499.22687.39 · Cited by 80
de Sousa, M. R., Morillo, C. A., Rabelo, F. T., Filho, A. M. N., & Ribeiro, A. L. P. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.07.002 · Cited by 72
Sosa, E., Scanavacca, M., d’Ávila, A., Antônio, J., & Ramires, F. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000026925.41543.7c · Cited by 72
Metadata
- Authors
- Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., Brown, M. W., & Heo, M.
- Affiliations
- University of Rochester Medicine (US)
- Good Samaritan Hospital (US)
- Scripps Memorial Hospital (US)
- University Hospital Magdeburg (DE)
- St. Francis Hospital (US)
- University Hospitals of Cleveland (US)
- University of Chicago (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1996-12-26
- Volume
- 335
- Issue
- 26
- Pages
- 1933-1940
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2320382602
- Cited by
- 4,165
- References
- 25
- Citations by year
- 2026: 40 · 2025: 61 · 2024: 54 · 2023: 61 · 2022: 97 · 2021: 70 · 2020: 85 · 2019: 98 · 2018: 106 · 2017: 151 · 2016: 145 · 2015: 136 · 2014: 145 · 2013: 154 · 2012: 171
- FWCI
- 93.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- implantable cardioverter-defibrillator, ventricular tachyarrhythmia, myocardial infarction, left ventricular dysfunction, survival, antiarrhythmic therapy, amiodarone, beta-blockers, high-risk patients
- MeSH terms
- Adult, Aged, Anti-Arrhythmia Agents, Coronary Disease, Female, Humans, Male, Middle Aged, Myocardial Infarction, Risk Factors, Proportional Hazards Models, Survival Analysis, Defibrillators, Implantable, Tachycardia, Ventricular, Ventricular Dysfunction, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.