Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular Arrhythmia
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Unsustained ventricular tachycardia in patients with previous myocardial infarction and left ventricular dysfunction is associated with a two-year mortality rate of about 30 percent. We studied whether prophylactic therapy with an implanted cardioverter-defibrillator, as compared with conventional medical therapy, would improve survival in this high-risk group of patients. METHODS: Over the course of five years, 196 patients in New York Heart Association functional class I, II, or III with prior myocardial infarction; a left ventricular ejection fraction < or = 0.35; a documented episode of asymptomatic unsustained ventricular tachycardia; and inducible, nonsuppressible ventricular tachyarrhythmia on electrophysiologic study were randomly assigned to receive an implanted defibrillator (n = 95) or conventional medical therapy (n=101). We used a two-sided sequential design with death from any cause as the end point. RESULTS: The base-line characteristics of the two treatment groups were similar. During an average follow-up of 27 months, there were 15 deaths in the defibrillator group (11 from cardiac causes) and 39 deaths in the conventional-therapy group (27 from cardiac causes) (hazard ratio for overall mortality, 0.46; 95 percent confidence interval, 0.26 to 0.82; P=0.009). There was no evidence that amiodarone, beta-blockers, or any other antiarrhythmic therapy had a significant influence on the observed hazard ratio. CONCLUSIONS: In patients with a prior myocardial infarction who are at high risk for ventricular tachyarrhythmia, prophylactic therapy with an implanted defibrillator leads to improved survival as compared with conventional medical therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“NSVT accompanied by inducibility of sustained VT during programmed ventricular stimulation was associated with an increased risk of SCD”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Moss et al., 1996
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Echt, D. S., Liebson, P. R., Mitchell, L. B., Peters, R. W., Obias-Manno, D., Barker, A. H., Arensberg, D., Baker, A., Friedman, L., Greene, H. L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241201 · Cited by 3,253
Mirowski, M., Reid, P. R., Mower, M. M., Watkins, L., Gott, V. L., Schauble, J. F., Langer, A., Heilman, M. S., Kolenik, S. A., Fischell, R. E., et al. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008073030607 · Cited by 1,361
Bigger, J. T., Fleiss, J. L., Kleiger, R., Miller, J. P., & Rolnitzky, L. M. (1984) · Circulation · doi:10.1161/01.cir.69.2.250 · Cited by 1,286
Amiodarone in Patients with Congestive Heart Failure and Asymptomatic Ventricular Arrhythmia
Singh, S. N., Fletcher, R. D., Fisher, S. G., Singh, B. N., Lewis, H. D., Deedwania, P. C., Massie, B. M., Colling, C., & Lazzeri, D. (1995) · New England Journal of Medicine · doi:10.1056/nejm199507133330201 · Cited by 1,225
Long-term outcome with the automatic implantable cardioverter-defibrillator
Winkle, R. A., Mead, R. H., Ruder, M. A., Gaudiani, V. A., Smith, N. A., Buch, W. S., Schmidt, P., & Shipman, T. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90310-0 · Cited by 719
Clinical classification of cardiac deaths.
Hinkle, L. E., & Thaler, H. T. (1982) · Circulation · doi:10.1161/01.cir.65.3.457 · Cited by 638
A Comparison of Seven Antiarrhythmic Drugs in Patients with Ventricular Tachyarrhythmias
Mason, J. W. (1993) · New England Journal of Medicine · doi:10.1056/nejm199308123290702 · Cited by 462
Echt, D. S., Armstrong, K., Schmidt, P., Oyer, P. E., Stinson, E. B., & Winkle, R. A. (1985) · Circulation · doi:10.1161/01.cir.71.2.289 · Cited by 452
Cited by
Items 301–400 of 1,004
Quality of life in implanted cardioverter defibrillator recipients: The impact of a device shock
Carroll, D. L., & Hamilton, G. A. (2005) · Heart & Lung · doi:10.1016/j.hrtlng.2004.10.002 · Cited by 132
Zaman, S. J., & Kovoor, P. (2014) · Circulation · doi:10.1161/circulationaha.113.007497 · Cited by 142
“and a positive EPS study and demonstrated a survival benefit.(14) These findings were confirmed by the Multicenter Unsustained Tachycardia Trial (MUSTT) investigators in 1999.”
BackgroundMethodResultSEARS, S. F., SOWELL, L. D. V., KUHL, E. A., KOVACS, A. H., SERBER, E. R., HANDBERG, E., KNEIPP, S. M., ZINEH, I., & CONTI, J. B. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00773.x · Cited by 128
Zishiri, E. T., Williams, S., Cronin, E. M., Blackstone, E. H., Ellis, S. G., Roselli, E. E., Smedira, N. G., Gillinov, A. M., Glad, J. A., Tchou, P. J., et al. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.112.973552 · Cited by 132
The Cardiovascular Disease Continuum Validated: Clinical Evidence of Improved Patient Outcomes
Dzau, V. J., Antman, E. M., Black, H. R., Hayes, D. L., Manson, J. E., Plutzky, J., Popma, J. J., & Stevenson, W. G. (2006) · Circulation · doi:10.1161/circulationaha.106.655761 · Cited by 161
Quality of Life and Psychological Status of Patients With Implantable Cardioverter Defibrillators
Thomas, S. A., Friedmann, E., Kao, C.-W., Inguito, P., Metcalf, M., Kelley, F. J., & Gottlieb, S. S. (2006) · American Journal of Critical Care · doi:10.4037/ajcc2006.15.4.389 · Cited by 131
Implantable Cardioverter Defibrillator Therapy: The Sickest Patients Benefit the Most
Moss, A. J. (2000) · Circulation · doi:10.1161/01.cir.101.14.1638 · Cited by 131
Self-citationKlein, H., Meltendorf, U., Reek, S., SMID, J., KUSS, S., Cygankiewicz, I., Jøns, C., Szymkiewicz, S. J., Buhtz, F., WOLLBRUECK, A., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02590.x · Cited by 135
Self-citationObstructive Sleep Apnea and Cardiovascular Disease
Kato, M., Adachi, T., Koshino, Y., & Somers, V. K. (2009) · Circulation Journal · doi:10.1253/circj.cj-09-0364 · Cited by 142
Larsen, G. C., Hallstrom, A. P., McAnulty, J. H., Pinski, S. L., Olarte, A., Sullivan, S. D., Brodsky, M. A., Powell, J. L., Marchant, C., Jennings, C., et al. (2002) · Circulation · doi:10.1161/01.cir.0000015504.57641.d0 · Cited by 129
Rohacek, M., Weisser, M., Kobza, R., Schoenenberger, A. W., Pfyffer, G. E., Frei, R., Erné, P., & Trampuž, A. (2010) · Circulation · doi:10.1161/circulationaha.109.906461 · Cited by 134
Wäßnig, N. K., Günther, M., Quick, S., Pfluecke, C., Rottstädt, F., Szymkiewicz, S. J., Ringquist, S., Strasser, R. H., & Speiser, U. (2016) · Circulation · doi:10.1161/circulationaha.115.019124 · Cited by 134
Arnar, D. O., Mairesse, G. H., Boriani, G., Calkins, H. G., Chin, A., Coats, A. J. S., Deharo, J., Svendsen, J. H., Heidbüchel, H., Isa, R., et al. (2019) · EP Europace · doi:10.1093/europace/euz046 · Cited by 141
Koller, M., Schaer, B. A., Wolbers, M., Sticherling, C., Bucher, H. C., & Osswald, S. (2008) · Circulation · doi:10.1161/circulationaha.107.742155 · Cited by 141
Hohnloser, S. H., Klingenheben, T., Zabel, M., Schöpperl, M., & Mauß, O. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00108-4 · Cited by 125
Nonsustained Ventricular Tachycardia
Katritsis, D. G., Zaręba, W., & Camm, A. J. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.063 · Cited by 136
Piccini, J. P., Allen, L. A., Kudenchuk, P. J., Page, R. L., Patel, M. R., & Turakhia, M. P. (2016) · Circulation · doi:10.1161/cir.0000000000000394 · Cited by 133
Patel, R. B., Ng, J., Reddy, V. K., Chokshi, M., Parikh, K. S., Subacius, H. P., Alsheikh-Ali, A. A. A., Nguyen, T., Link, M. S., Goldberger, J. J., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.921130 · Cited by 129
Dietz, R., & Rauch, B. (2003) · Zeitschrift für Kardiologie · doi:10.1007/s00392-003-0960-1 · Cited by 215
“der Beeinträchtigung der Pumpfunktion (ischämisch bedingte Herzinsuffizienz) (65) Rhythmusstörungen zur Folge haben (15, 98, 99).”
BackgroundRuwald, A., Schuger, C. D., Moss, A. J., Kutyifa, V., Olshansky, B., Greenberg, H., Cannom, D. S., Estes, N. A. M., Ruwald, M. H., Huang, D. T.-C., et al. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001623 · Cited by 130
Self-citationSteinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 133
Design and Results of the Antiarrhythmics vs Implantable Defibrillators (AVID) Registry
Anderson, J. L., Hallstrom, A. P., Epstein, A. E., Pinski, S. L., Rosenberg, Y., Nora, M. O., Chilson, D., Cannom, D. S., & Moore, R. (1999) · Circulation · doi:10.1161/01.cir.99.13.1692 · Cited by 124
Self-citationDamman, K., Tang, W. H. W., Felker, G. M., Lassus, J., Zannad, F., Krum, H., & McMurray, J. J. V. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.11.031 · Cited by 122
Sabbag, A., Suleiman, M. A., Laish‐Farkash, A., Samania, N., Kazatsker, M., Goldenberg, I., Glikson, M., & Beinart, R. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.08.020 · Cited by 122
Value of Programmed Ventricular Stimulation in Patients with Congenital Heart Disease
ALEXANDER, M. E., WALSH, E. P., SAUL, J. P., EPSTEIN, M. R., & TRIEDMAN, J. K. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00274.x · Cited by 123
Mela, T., McGovern, B. A., Garan, H., Vlahakes, G. J., Torchiana, D. F., Ruskin, J. N., & Galvin, J. M. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01845-8 · Cited by 122
Shocks burden and increased mortality in implantable cardioverter-defibrillator patients
Larsen, G. K., Evans, J., Lambert, W. E., Chen, Y., & Raitt, M. H. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.07.036 · Cited by 121
Krahn, A. D., Connolly, S. J., Roberts, R. S., & Gent, M. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.12.017 · Cited by 121
Cost-Effectiveness of the Implantable Cardioverter-Defibrillator
OʼBrien, B. J., Connolly, S. J., Goeree, R. A., Blackhouse, G., Willan, A. R., Yee, R. K., Roberts, R. S., & Gent, M. (2001) · Circulation · doi:10.1161/01.cir.103.10.1416 · Cited by 121
KADISH, A. H., BELLO, D., FINN, J. P., BONOW, R. O., SCHAECHTER, A., SUBACIUS, H., ALBERT, C., DAUBERT, J. P., FONSECA, C. G., & GOLDBERGER, J. J. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01503.x · Cited by 118
Self-citationCharytan, D. M., Patrick, A. R., Liu, J., Setoguchi, S., Herzog, C. A., Brookhart, M. A., & Winkelmayer, W. C. (2011) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2011.03.026 · Cited by 121
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., CHAITMAN, B. R., FROMER, M. A., Gregoratos, G., Klein, G. J., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178104 · Cited by 128
Self-citationGoldstein, N. E., Mehta, D., Teitelbaum, E., Bradley, E. H., & Morrison, R. S. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0237-x · Cited by 118
Ventricular Fibrillation Triggered by PVCs from Papillary Muscles: Clinical Features and Ablation
Santoro, F., Biase, L. D., Hranitzky, P. M., Sánchez, J., Santangeli, P., Perini, A. P., BURKHARDT, J. D., & Natale, A. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12478 · Cited by 117
Lipshultz, S. E., Cochran, T. R., Briston, D. A., Brown, S. R., Sambatakos, P. J., Miller, T. L., Carrillo, A. A., Corcia, L., Sanchez, J. E., Diamond, M. B., et al. (2013) · Future Cardiology · doi:10.2217/fca.13.66 · Cited by 102
Update on heart failure management and future directions
Choi, H., Park, M., & Youn, J. (2018) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2018.428 · Cited by 129
“Conventional pharmacological treatment Pharmacological treatment of HF has been evolving through increased understanding of its pathophysiology and the development of new drugs (Table 1 [54-89], Fig.”
BackgroundGroh, C. A., Sharma, S., Pelchovitz, D. J., Bhave, P. D., Rhyner, J., Verma, N., Arora, R., Chicos, A. B., Kim, S. S., LIN, A. C., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.04.025 · Cited by 116
Subcutaneous Versus Transvenous Implantable Defibrillator Therapy
Basu‐Ray, I., Liu, J., Jia, X., Gold, M. R., Ellenbogen, K. A., DiNicolantonio, J. J., Komócsi, A., Vorobcsuk, A., Kim, J.-T., Afshar, H., et al. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.07.017 · Cited by 116
Al‐Khatib, S. M., Greiner, M. A., Peterson, E. D., Hernandez, A. F., Schulman, K. A., & Curtis, L. H. (2008) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.777888 · Cited by 120
van Welsenes, G. H., van Rees, J. B., Borleffs, C. J. W., Cannegieter, S. C., Bax, J. J., van Erven, L., & Schalij, M. J. (2011) · EP Europace · doi:10.1093/europace/euq494 · Cited by 116
“Randomized trials tested the hypothesis that ICD treatment was beneficial in a population characterized by depressed left ventricular ejection fraction (LVEF) without prior cardiac arrest and demonstrated a reduction in all-cause mortality.(8-11) Not only did the implementation of these results in the international gu…”
Clinical and Economic Implications of the Multicenter Automatic Defibrillator Implantation Trial-II
Al-Khatib, S. M., Anstrom, K. J., Eisenstein, E. L., Peterson, E. D., Jollis, J. G., Mark, D. B., Li, Y., O'Connor, C. M., Shaw, L. K., & Califf, R. M. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-8-200504190-00007 · Cited by 119
“In the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-I and Multicenter UnSustained Tachycardia Trial (MUSTT), such patients had appreciably better survival with an ICD compared with antiarrhythmic medications or no antiarrhythmic therapy (3, 4).”
BackgroundStellbrink, C., Auricchio, A., Diem, B., Breithardt, O. A., Kloss, M., Schöndube, F. A., Klein, H., Messmer, B. J., & Hanrath, P. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)01016-9 · Cited by 123
Self-citationDunbar, S. B., Kimble, L. P., Jenkins, L. S., Hawthorne, M., Dudley, W., Slemmons, M., & Langberg, J. J. (1999) · Depression and Anxiety · doi:10.1002/(sici)1520-6394(1999)9:4<163::aid-da3>3.0.co;2-b · Cited by 115
“The implanted cardioverter defibrillator (ICD) has become the standard of care for these patients and also has been shown to prolong life when used in asymptomatic patients at high risk for malignant ventricular arrhythmias [Moss et al., 1996; AVID Investigators, 1997; Owens et al., 1997].”
BackgroundRecommendations from the Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines
Maisel, W. H., Hauser, R. G., Hammill, S. C., Hauser, R. G., Ellenbogen, K. A., Epstein, A. E., Hayes, D. L., Alpert, J. S., Berger, R. D., Curtis, A. B., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.024 · Cited by 114
Koneru, J. N., Jones, P. W., Hammill, E. F., Wold, N. D., & Ellenbogen, K. A. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.117.007691 · Cited by 117
Shrinking lung in primary Sj�gren's syndrome
Tavoni, A. G., Vitali, C., Cirigliano, G., Frigelli, S., Stampacchia, G., & Bombardieri, S. (1999) · Arthritis & Rheumatism · doi:10.1002/1529-0131(199910)42:10<2174::aid-anr19>3.0.co;2-g · Cited by 45
Klein, H., Goldenberg, I., & Moss, A. J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht167 · Cited by 114
Self-citationMacchia, A., Levantesi, G., Franzosi, M. G., Geraci, E., Maggioni, A. P., Marfisi, R., Nicolosi, G. L., Schweiger, C., Tavazzi, L., Tognoni, G., et al. (2005) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2005.04.008 · Cited by 113
“Although ACE inhibitors [10] and more recently eplerenone [11] have been shown to reduce sudden death in patients with overt CHF, only automatic implantable cardioverter defibrillators (AICDs) have been consistently shown to reduce total mortality and sudden death in the relatively small group of patients with severe…”
BackgroundWase, A., Basit, A., Nazir, R. A., Jamal, A., Shah, S. S., Khan, T., Mohiuddin, I. H., White, C., Saklayen, M. G., & McCullough, P. A. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000048570.43706.34 · Cited by 113
“... underwent implantation if they met the following criteria: (1) Multicenter Automatic Defibrillation Implantation Trial Investigator (MADIT) criteria: Non-sustained VT in patients with coronary artery disease (CAD), previous MI, left ventricular (LV) dysfunction, and a left ventricular ejection fraction 10 ], (2) .…”
Wu, L. A., & Kottke, T. E. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(00)00278-x · Cited by 115
de Diagnóstico, G. D. T., & de Cardiología, T. D. L. I. C. C. D. L. S. E. (2005) · Revista Española de Cardiología · doi:10.1157/13078554 · Cited by 130
Molecular biology and the prolonged QT syndromes
Towbin, J. A., & Vatta, M. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00715-4 · Cited by 113
Pun, P. H., Al‐Khatib, S. M., Han, J. Y., Edwards, R., Bardy, G. H., Bigger, J. T., Buxton, A. E., Moss, A. J., Lee, K. L., Steinman, R. C., et al. (2014) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2013.12.009 · Cited by 116
Self-citationRohde, L. E. P., Chatterjee, N. A., Vaduganathan, M., Claggett, B. L., Packer, M., Desai, A. S., Zile, M. R., Rouleau, J. L., Swedberg, K. B., Lefkowitz, M. P., et al. (2020) · JACC Heart Failure · doi:10.1016/j.jchf.2020.06.015 · Cited by 135
2026 ESC Guidelines for the management of heart failure
Køber, L., Adamo, M., Ruwald, A., Tomasoni, D., Anderson, L., Andersson, C., Brugts, J. J., Chioncel, O. D., Donal, E., Ferdinandy, P., et al. (2026) · European Heart Journal · doi:10.1093/eurheartj/ehag100 · Cited by 169
Cannon, B. C., Friedman, R. A., Fenrich, A. L., Fraser, C. D., McKenzie, E. D., & Kertesz, N. J. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00314.x · Cited by 111
Hauser, R. G., & Kallinen, L. M. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.05.006 · Cited by 111
QRS duration: a simple marker for predicting cardiac mortality in ICD patients with heart failure
Bode-Schnurbus, L., Böcker, D., Block, M., Gradaus, R., Heinecke, A., Breithardt, G., & Borggrefe, M. (2003) · Heart · doi:10.1136/heart.89.10.1157 · Cited by 111
Hess, P. L., Al-Khatib, S. M., Han, J. Y., Edwards, R., Bardy, G. H., Bigger, J. T., Buxton, A., Cappato, R., Dorian, P., Hallstrom, A., et al. (2015) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.114.001306 · Cited by 107
Self-citationTrujillo, T. C., & Nolan, P. E. (2000) · Drug Safety · doi:10.2165/00002018-200023060-00003 · Cited by 110
Prediction and prevention of sudden cardiac death in heart failure
Lane, R., Cowie, M., & CHOW, A. W. C. (2005) · Heart · doi:10.1136/hrt.2003.025254 · Cited by 119
Risk of Failure of Transvenous Implantable Cardioverter-Defibrillator Leads
Borleffs, C. J. W., van Erven, L., van Bommel, R. J., van der Velde, E. T., van der Wall, E. E., Bax, J. J., Rosendaal, F. R., & Schalij, M. J. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.834093 · Cited by 108
Butler, J., McMullan, C. J., Anstrom, K. J., Barash, I., Bonaca, M. P., Borentain, M., Corda, S., Ezekowitz, J. A., Felker, G. M., Gates, D. F., et al. (2025) · The Lancet · doi:10.1016/s0140-6736(25)01665-4 · Cited by 121
Kantelhardt, J. W., Bauer, A., Schumann, A. Y., Barthel, P., Schneider, R., Malík, M., & Schmidt, G. P. (2007) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.2430636 · Cited by 135
Temporary epicardial pacing after cardiac surgery: a practical review
Reade, M. C. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.04950.x · Cited by 108
Epidemiology and stratification of risk for sudden cardiac death
Podrid, P. J., & Myerburg, R. J. (2009) · Clinical Cardiology · doi:10.1002/clc.4960281303 · Cited by 120
Gradaus, R., Block, M. S., Brachmann, J., BREITHARDT, G. E., HUBER, H. G., Jung, W., Kranig, W., Mletzko, R., Schoels, W., Seidl, K., et al. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00219.x · Cited by 107
Cutler, M. J., Wan, X., Plummer, B. N., Liu, H., Deschênes, I., Laurita, K. R., Hajjar, R. J., & ROSENBAUM, D. S. (2012) · Circulation · doi:10.1161/circulationaha.111.071480 · Cited by 117
Nielsen, J. C., Lin, Y., Figueiredo, M. J. D. O., Shamloo, A. S., Alfie, A., Bovéda, S., Dagres, N., Toro, D. D., Eckhardt, L. L., Ellenbogen, K. A., et al. (2020) · Journal of Arrhythmia · doi:10.1002/joa3.12338 · Cited by 109
Cost Effectiveness of Defibrillation by Targeted Responders in Public Settings
Nichol, G., Valenzuela, T. D., Roe, D. J., Clark, L. L., Huszti, E., & Wells, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000084545.65645.28 · Cited by 116
Goldenberg, I., Moss, A. J., McNitt, S. A., Zaręba, W., Hall, W. J., Andrews, M. L., Wilber, D. J., & Klein, H. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.048 · Cited by 104
Self-citationIndications for Implantable Cardioverter-Defibrillators Based on Evidence and Judgment
Myerburg, R. J., Reddy, V. Y., & Castellanos, A. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.078 · Cited by 112
Implantable Cardioverter Defibrillator Therapy for Life-Threatening Arrhythmias in Young Patients
Stefanelli, C. B., Bradley, D. J., Leroy, S., Dick, M., Serwer, G. A., & Fischbach, P. (2002) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1019509803992 · Cited by 104
Importance of beta blockade in the therapy of serious ventricular arrhythmias
Reiter, M. J., & Reiffel, J. A. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00468-8 · Cited by 109
Demonstration of nonlinear components in heart rate variability of healthy persons
Braun, C., KOWALLIK, P., Freking, A., Hadeler, D., Kniffki, K., & Meesmann, M. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.5.h1577 · Cited by 127
Clinical experience with a novel subcutaneous implantable defibrillator system in a single center
Abkenari, L. D., Theuns, D. A. M. J., Valk, S. D. A., Belle, Y. V., de Groot, N. M. S., Haitsma, D. B., Muskens, A. J. Q. M., Szili‐Törok, T., & Jordaens, L. J. L. M. (2011) · Clinical Research in Cardiology · doi:10.1007/s00392-011-0303-6 · Cited by 108
Fonarow, G. C., Feliciano, Z., Boyle, N. G., Knight, L., Woo, M. A., Moriguchi, J. D., Laks, H., & Wiener, I. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00914-5 · Cited by 105
The DAVID (Dual Chamber and VVI Implantable Defibrillator) II Trial
Wilkoff, B. L., Kudenchuk, P. J., Buxton, A. E., Sharma, A. D., Cook, J. R., Bhandari, A. K., Biehl, M. L., TOMASSONI, G. F., Leonen, A. O., Klevan, L. R., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.057 · Cited by 107
Bennett, M. T., Parkash, R., Nery, P. B., Sénéchal, M., Mondesert, B. A., BIRNIE, D. H., Sterns, L. D., Rinne, C., Exner, D. V., Philippon, F., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.09.009 · Cited by 109
Sohail, M. R., Eby, E. L., Ryan, M. P., Gunnarsson, C., Wright, L. A., & Greenspon, A. J. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.116.003929 · Cited by 108
Prognosis determination in heart failure
Eichhorn, E. J. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(98)00384-2 · Cited by 107
An updated review of implantable cardioverter/defibrillators, induced anxiety, and quality of life.
Bostwick, J. M., & Sola, C. L. (2007) · Psychiatric Clinics of North America · doi:10.1016/j.psc.2007.07.002 · Cited by 101
Natale, A., Raviele, A., Al‐Ahmad, A., Alfieri, O., Aliot, E., Almendral, J. M., Breithardt, G., Brugada, J., Calkins, H. G., Callans, D. J., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01686.x · Cited by 102
Self-citationSelvanayagam, J. B., Hartshorne, T., Billot, L., Grover, S., Hillis, G. S., Jung, W., Krum, H., Prasad, S. K., & McGavigan, A. D. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12420 · Cited by 101
Bunch, T. J., White, R. D., Friedman, P. A., Kottke, T. E., Wu, L. A., & Packer, D. L. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.04.017 · Cited by 101
Shun-Shin, M. J., Zheng, S. L., Cole, G. D., Howard, J. P., Whinnett, Z. I., & Francis, D. P. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx028 · Cited by 107
Friedman, P. A., MURGATROYD, F. D., Boersma, L. V. A., Manlucu, J., Knight, B. P., Clémenty, N., Leclercq, C., Amin, A. K., Merkely, B. P., Birgersdotter-Green, U. M., et al. (2024) · Circulation · doi:10.1161/circulationaha.124.071795 · Cited by 100
Danik, S. B., MANSOUR, M. C., Singh, J. P., Reddy, V. Y., Ellinor, P. T., Milan, D. J., Heist, E. K., d’Ávila, A., Ruskin, J. N., & Mela, T. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.044 · Cited by 100
Outcomes of Implantable Cardioverter-Defibrillator Use in Patients With Comorbidities
Steinberg, B. A., Al-Khatib, S. M., Edwards, R., Han, J., Bardy, G. H., Bigger, J. T., Buxton, A. E., Moss, A. J., Lee, K. L., Steinman, R., et al. (2014) · JACC: Heart Failure · doi:10.1016/j.jchf.2014.06.007 · Cited by 98
“Subsequently, patient-level data from 4 major prospective randomized trials of ICDs were combined: MADIT I (Multicenter Automatic Defibrillator Implantation Trial I) (1), MADIT II (3), DEFINITE (Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation) (4), and SCD-HeFT (Sudden Cardiac Death in Heart Failure…”
MethodSelf-citationLip, G. Y. H., Heinzel, F. R., Gaïta, F., González‐Juanatey, J. R., Heuzey, J. Y. L., Potpara, T., Svendsen, J. H., Vos, M. A., Anker, S. D., Coats, A. J. S., et al. (2015) · EP Europace · doi:10.1093/europace/euv191 · Cited by 116
Nielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Al‐Khatib, S. M., Hellkamp, A. S., Bardy, G. H., Hammill, S. C., Hall, W. J., Mark, D. B., Anstrom, K. J., Curtis, J. P., Al‐Khalidi, H. R., Curtis, L. H., et al. (2013) · JAMA · doi:10.1001/jama.2012.157182 · Cited by 97
Self-citationAuricchio, A., Metra, M., Gasparini, M., Lamp, B., Klersy, C., Curnis, A., Fantoni, C., Gronda, E., & Vogt, J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.07.087 · Cited by 97
Long-term results after ablation of infarct-related ventricular tachycardia
Segal, O. R., CHOW, A. W. C., Markides, V., SCHILLING, R. J., Peters, N. S., & Davies, D. W. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.01.017 · Cited by 97
Implantable Cardiac Device Procedures in Older Patients: Use and In-Hospital Outcomes
Swindle, J. P., Rich, M. W., McCann, P., Burroughs, T. E., & Hauptman, P. J. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.30 · Cited by 103
What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up?
Brugada, P. (2006) · Clinical Research in Cardiology · doi:10.1007/s00392-006-1302-x · Cited by 104
The Design of a Thermoelectric Generator and Its Medical Applications
Kumar, P. M., Babu, V. J., Subramanian, A., Bandla, A., Thakor, N. V., Ramakrishna, S., & He, W. (2019) · Designs · doi:10.3390/designs3020022 · Cited by 100
“Later, implantable cardioverter-defibrillators were developed for detecting cardiac arrhythmia and correcting through electric pulses [82].”
Risk stratification in surgically repaired tetralogy of Fallot
Khairy, P., Dore, A., Poirier, N., Marcotte, F., Ibrahim, R., Mongeon, F.-P., & Mercier, L.-A. (2009) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.09.38 · Cited by 95
Anderson, K. P. (2005) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-005-4547-9 · Cited by 96
Remote Interrogation and Monitoring of Implantable Cardioverter Defibrillators
Joseph, G. K., Wilkoff, B. L., Dresing, T., BURKHARDT, J. D., & Khaykin, Y. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000042356.52369.89 · Cited by 95
Metadata
- Authors
- Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., Brown, M. W., & Heo, M.
- Affiliations
- University of Rochester Medicine (US)
- Good Samaritan Hospital (US)
- Scripps Memorial Hospital (US)
- University Hospital Magdeburg (DE)
- St. Francis Hospital (US)
- University Hospitals of Cleveland (US)
- University of Chicago (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1996-12-26
- Volume
- 335
- Issue
- 26
- Pages
- 1933-1940
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2320382602
- Cited by
- 4,165
- References
- 25
- Citations by year
- 2026: 40 · 2025: 61 · 2024: 54 · 2023: 61 · 2022: 97 · 2021: 70 · 2020: 85 · 2019: 98 · 2018: 106 · 2017: 151 · 2016: 145 · 2015: 136 · 2014: 145 · 2013: 154 · 2012: 171
- FWCI
- 93.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- implantable cardioverter-defibrillator, ventricular tachyarrhythmia, myocardial infarction, left ventricular dysfunction, survival, antiarrhythmic therapy, amiodarone, beta-blockers, high-risk patients
- MeSH terms
- Adult, Aged, Anti-Arrhythmia Agents, Coronary Disease, Female, Humans, Male, Middle Aged, Myocardial Infarction, Risk Factors, Proportional Hazards Models, Survival Analysis, Defibrillators, Implantable, Tachycardia, Ventricular, Ventricular Dysfunction, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.