Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular Arrhythmia
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 25 of the 25 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Unsustained ventricular tachycardia in patients with previous myocardial infarction and left ventricular dysfunction is associated with a two-year mortality rate of about 30 percent. We studied whether prophylactic therapy with an implanted cardioverter-defibrillator, as compared with conventional medical therapy, would improve survival in this high-risk group of patients. METHODS: Over the course of five years, 196 patients in New York Heart Association functional class I, II, or III with prior myocardial infarction; a left ventricular ejection fraction < or = 0.35; a documented episode of asymptomatic unsustained ventricular tachycardia; and inducible, nonsuppressible ventricular tachyarrhythmia on electrophysiologic study were randomly assigned to receive an implanted defibrillator (n = 95) or conventional medical therapy (n=101). We used a two-sided sequential design with death from any cause as the end point. RESULTS: The base-line characteristics of the two treatment groups were similar. During an average follow-up of 27 months, there were 15 deaths in the defibrillator group (11 from cardiac causes) and 39 deaths in the conventional-therapy group (27 from cardiac causes) (hazard ratio for overall mortality, 0.46; 95 percent confidence interval, 0.26 to 0.82; P=0.009). There was no evidence that amiodarone, beta-blockers, or any other antiarrhythmic therapy had a significant influence on the observed hazard ratio. CONCLUSIONS: In patients with a prior myocardial infarction who are at high risk for ventricular tachyarrhythmia, prophylactic therapy with an implanted defibrillator leads to improved survival as compared with conventional medical therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“NSVT accompanied by inducibility of sustained VT during programmed ventricular stimulation was associated with an increased risk of SCD”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Moss et al., 1996
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Echt, D. S., Liebson, P. R., Mitchell, L. B., Peters, R. W., Obias-Manno, D., Barker, A. H., Arensberg, D., Baker, A., Friedman, L., Greene, H. L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241201 · Cited by 3,253
Mirowski, M., Reid, P. R., Mower, M. M., Watkins, L., Gott, V. L., Schauble, J. F., Langer, A., Heilman, M. S., Kolenik, S. A., Fischell, R. E., et al. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008073030607 · Cited by 1,361
Bigger, J. T., Fleiss, J. L., Kleiger, R., Miller, J. P., & Rolnitzky, L. M. (1984) · Circulation · doi:10.1161/01.cir.69.2.250 · Cited by 1,286
Amiodarone in Patients with Congestive Heart Failure and Asymptomatic Ventricular Arrhythmia
Singh, S. N., Fletcher, R. D., Fisher, S. G., Singh, B. N., Lewis, H. D., Deedwania, P. C., Massie, B. M., Colling, C., & Lazzeri, D. (1995) · New England Journal of Medicine · doi:10.1056/nejm199507133330201 · Cited by 1,225
Long-term outcome with the automatic implantable cardioverter-defibrillator
Winkle, R. A., Mead, R. H., Ruder, M. A., Gaudiani, V. A., Smith, N. A., Buch, W. S., Schmidt, P., & Shipman, T. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90310-0 · Cited by 719
Clinical classification of cardiac deaths.
Hinkle, L. E., & Thaler, H. T. (1982) · Circulation · doi:10.1161/01.cir.65.3.457 · Cited by 638
A Comparison of Seven Antiarrhythmic Drugs in Patients with Ventricular Tachyarrhythmias
Mason, J. W. (1993) · New England Journal of Medicine · doi:10.1056/nejm199308123290702 · Cited by 462
Echt, D. S., Armstrong, K., Schmidt, P., Oyer, P. E., Stinson, E. B., & Winkle, R. A. (1985) · Circulation · doi:10.1161/01.cir.71.2.289 · Cited by 452
Cited by
Items 601–700 of 1,004
Berenbom, L., Weiford, B. C., Vacek, J. L., Emert, M. P., Hall, W. J., Andrews, M. L., McNitt, S. A., Zaręba, W., Moss, A. J., & for the MADIT‐II Investigators (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00063.x · Cited by 59
Self-citationFilho, M. M., de Siqueira, S. F., MOREIRA, H., FAGUNDES, A., Pedrosa, A., Nishioka, S. D., Costa, R., Scanavacca, M., d’Ávila, A., & Sosa, E. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb07058.x · Cited by 59
Cleland, J. G. F. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2570 · Cited by 59
Arrhythmias in Heart Failure: Current Concepts of Mechanisms and Therapy
Eckardt, L., Haverkamp, W., Johna, R., Böcker, D., Deng, M. C.-H. K., Breithardt, G., & BORGGREEE, M. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00746.x · Cited by 60
Management of Ventricular Arrhythmias: Detection, Drugs, and Devices
Cannom, D. S., & Prystowsky, E. N. (1999) · JAMA · doi:10.1001/jama.281.2.172 · Cited by 73
Self-citationThackray, S. D. R., Coletta, A. P., Jones, P., Dunn, A., Clark, A. L., & Cleland, J. G. F. (2001) · European Journal of Heart Failure · doi:10.1016/s1388-9842(01)00175-1 · Cited by 59
Risk factors for cardiac implantable electronic device infections: a nationwide Danish study
Olsen, T., Jørgensen, O. D., Nielsen, J. C., Thøgersen, A. M., Philbert, B. T., Frausing, M. H. J. P., Sandgaard, N. C. F., & Johansen, J. B. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac576 · Cited by 58
Butler, J., Ezekowitz, J. A., Collins, S. P., Givertz, M. M., Teerlink, J. R., Walsh, M. N., Albert, N. M., Canary, C. A. W., Carson, P. E., Colvin, M. M., et al. (2012) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2012.02.005 · Cited by 63
Cardiac Arrest: the Changing Incidence of Ventricular Fibrillation
Keller, S. P., & Halperin, H. R. (2015) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-015-0392-z · Cited by 58
Cardiac Implantable Electronic Device Therapy in Heart Failure
Hussein, A. A., & Wilkoff, B. L. (2019) · Circulation Research · doi:10.1161/circresaha.118.313571 · Cited by 60
End‐of‐Life Care in Patients with Implantable Cardioverter Defibrillators: A MADIT‐II Substudy
Sherazi, S., McNitt, S. A., Aktaş, M. K., Polonsky, B., Shah, A. H., Moss, A. J., Daubert, J. P., & Zaręba, W. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12188 · Cited by 62
Self-citationVersorgungsLeitlinie, N. (2011) · Cited by 58
Arrhythmias in Female Patients: Incidence, Presentation and Management
Zeitler, E. P., Poole, J. E., Albert, C. M., Al-Khatib, S. M., Ali-Ahmed, F., Birgersdotter-Green, U., Cha, Y.-M., Chung, M. K., Curtis, A. B., Hurwitz, J. L., et al. (2022) · Circulation Research · doi:10.1161/circresaha.121.319893 · Cited by 61
Patient satisfaction and suggestions for improvement of remote ICD monitoring
Petersen, H. H., Larsen, M. C. J., Nielsen, O. W., Kensing, F., & Svendsen, J. H. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9675-4 · Cited by 64
Biffi, M., Ziacchi, M., Bertini, M., Sangiorgi, D., Corsini, D., Martignani, C., Diemberger, I., & Boriani, G. (2008) · EP Europace · doi:10.1093/europace/eun240 · Cited by 57
Bermejo, R. A., Babarro, E. G., Canoa, J. N. L., Roman, A. V., Otero, I. G., Oro‐Ayude, M., Vazquez, P. P., Rodríguez, I. G., Castro, Ó. D., & González‐Juanatey, J. R. (2017) · Cardiology Journal · doi:10.5603/cj.a2017.0103 · Cited by 61
“When the baseline characteristics of HpEF, HFrEF and HFrecEF patients were analyzed, observations revealed statistically significant differences in age, sex, smoking, previous myocardial infarction, previous percutaneous revascularization, previous device (ICD/CRT) implantation, systolic blood pressure, New York Heart…”
BackgroundInfluentialSILVA, R. M. F. L., Mont, L., Nava, S., Rojel-Martínez, U., Matas, M., & Brugada, J. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00567.x · Cited by 57
Naccarelli, G. V., Wolbrette, D. L., Patel, H. M., & Luck, J. C. (2000) · Current Opinion in Cardiology · doi:10.1097/00001573-200001000-00009 · Cited by 57
Demirel, F., Adiyaman, A., Timmer, J. R., Dambrink, J. E., Kok, M., Boeve, W. J., & Elvan, A. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.08.132 · Cited by 59
Rinaldi, C. A., Simón, R., Geelen, P., Reek, S., Baszko, A., Kuehl, M., & Gill, J. S. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00253.x · Cited by 56
Sudden Cardiac Death From the Perspective of Coronary Artery Disease
Sara, J. D. S., Eleid, M. F., Gulati, R., & Holmes, D. R. (2014) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2014.08.022 · Cited by 62
Ripplinger, C. M., Noujaim, S. F., & Linz, D. (2016) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2015.12.015 · Cited by 55
“…system to prevent ventricular arrhythmia The effectiveness of implantable cardioverter-defibrillators (ICDs) for primary and secondary preventions of sudden cardiac death has resulted in an increasing number of patients presenting with recurrent, appropriate ICD shocks for VT (Moss et al., 1996).”
BackgroundKołodziejczak, M. M., Andreotti, F., Kowalewski, M., Buffon, A., Ciccone, M. M., Parati, G., Scicchitano, P., Umińska, J. M., Servi, S. D., Bliden, K. P., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m17-0120 · Cited by 64
“Nonischemic cardiomyopathy AMIOVIRT (13) CAT (11) DANISH (6) DEFINITE (12) SCD-HeFT (15) Subtotal Ischemic cardiomyopathy CABG-PATCH (20) DINAMIT (19) IRIS (16) MADIT (17) MADIT II (18) MUSTT (18) SCD-HeFT (15) Subtotal Total 0.”
BackgroundInfluentialPlacement of Transvenous Pacemaker and ICD Leads Across Total Chronic Occlusions
McCOTTER, C. J., Angle, J. F., Prudente, L. A., Mounsey, J. P., Ferguson, J., Dimarco, J., Hummel, J. P., & Mangrum, J. M. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00203.x · Cited by 56
Adamson, P. B., CONTI, J. B., Smith, A. L., Abraham, W. T., Aaron, M. F., Aranda, J. M., Baker, J. H., Bourge, R. C., Warner‐Stevenson, L., & Sparks, B. S. (2007) · Clinical Cardiology · doi:10.1002/clc.20250 · Cited by 56
Trans Fatty Acids and Coronary Heart Disease
Zaloga, G. P., Harvey, K. A., Stillwell, W. H., & Siddiqui, R. A. (2006) · Nutrition in Clinical Practice · doi:10.1177/0115426506021005505 · Cited by 72
Ranković, V., Karha, J., PASSMAN, R. S., Kadish, A. H., & Goldberger, J. J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02278-6 · Cited by 56
Cook, J. R., Rizo-Patrón, C., Curtis, A. B., Gillis, A. M., Bigger, J. T., Kutalek, S. P., Coromilas, J., Hofer, B. I., Powell, J. L., & Hallstrom, A. P. (2002) · American Heart Journal · doi:10.1067/mhj.2002.121732 · Cited by 56
Cardiac Pacemakers and Implantable Defibrillators in Terminal Care
Braun, T. C., Hagen, N. A., Hatfield, R. E., & Wyse, D. G. (1999) · Journal of Pain and Symptom Management · doi:10.1016/s0885-3924(99)00038-x · Cited by 56
Bansal, N., Szpiro, A. A., Reynolds, K., Smith, D. H., Magid, D. J., Gurwitz, J. H., Masoudi, F. A., Greenlee, R. T., Tabada, G. H., Sung, S. H., et al. (2018) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.8462 · Cited by 55
Jazayeri, M., & Emert, M. P. (2019) · Medical Clinics of North America · doi:10.1016/j.mcna.2019.04.006 · Cited by 67
The subcutaneous implantable cardioverter-defibrillator in review
Kamp, N., & Al‐Khatib, S. M. (2019) · American Heart Journal · doi:10.1016/j.ahj.2019.08.010 · Cited by 55
“In July 2018, another metaanalysis of S-ICD versus TV-ICD was published,35 including the studies in the 2017 meta-analysis14,31-34 and 3 more studies.36-38 In total, this meta-analysis included N1,800 patient-years in the S-ICD arm and N2,200 patient-years in the TV-ICD.”
BackgroundInfluentialSudden cardiac death: Epidemiologic and financial worldwide perspective
Smith, T. W., & CAIN, M. E. (2006) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-9069-6 · Cited by 55
Reynolds, M. R., & Josephson, M. E. (2003) · Circulation · doi:10.1161/01.cir.0000086777.82110.f5 · Cited by 59
Current medical therapy for advanced heart failure
Gheorghiade, M., Cody, R. J., Francis, G. S., McKenna, W. J., Young, J. B., & Bonow, R. O. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70253-4 · Cited by 58
Prediction of sudden arrhythmic death following acute myocardial infarction
Liew, R. (2010) · Heart · doi:10.1136/hrt.2010.194407 · Cited by 55
Trials and tribulations of cell therapy for heart failure: an update on ongoing trials
Zhang, J. J., Pogwizd, S. M., Fukuda, K., Zimmermann, W., Fan, C., Hare, J. M., Bolli, R., & Menasché, P. (2024) · Nature Reviews Cardiology · doi:10.1038/s41569-024-01098-8 · Cited by 59
“effectiveness of ICDs have been demonstrated in numerous large-scale clinical trials, including MADIT 9 , MADIT-II 10 and SCD-HeFT 11 .”
HUIKURI, H. V., MAHAUX, V., BLOCH‐THOMSEN, P., & CARISMA Investigators (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00061.x · Cited by 55
Improvements in 25 Years of Implantable Cardioverter Defibrillator Therapy
van Welsenes, G. H., Borleffs, C. J. W., van Rees, J. B., Atary, J. Z., Thijssen, J., van der Wall, E. E., & Schalij, M. J. (2010) · Netherlands Heart Journal · doi:10.1007/s12471-010-0047-3 · Cited by 54
Bauer, A., Barthel, P., Müller, A., Ulm, K., Huikuri, H. V., Malík, M., & Schmidt, G. P. (2009) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2009.07.013 · Cited by 56
Antiarrhythmic and Nonantiarrhythmic Drugs for Sudden Cardiac Death Prevention
Das, M. K., & Zipes, D. P. (2010) · Journal of Cardiovascular Pharmacology · doi:10.1097/fjc.0b013e3181d64dde · Cited by 58
“DINAMIT showed reduction in arrhythmic deaths, but this benefit was offset by an increase in the rate of death from nonarrhythmic causes.43 The MADIT study established the initial ICD indication for primary prevention of SCD in patients with CAD.42 MADIT revealed that prophylactic therapy had an ICD improved survival…”
MethodInfluentialKuschyk, J., Stach, K., Tülümen, E., Rudic, B., Liebe, V., Schimpf, R., Borggrefe, M., & Röger, S. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.06.022 · Cited by 54
Kim, B., Jeon, D. S., Shin, M. J., Kim, Y. O., Song, H. C., Lee, S. H., Kim, S. Y., Choi, E. J., Chang, Y. S., & Bang, B. K. (2005) · American Journal of Nephrology · doi:10.1159/000085585 · Cited by 54
Davids, J. S., McPherson, C. A., Earley, C., Batsford, W. P., & Lampert, R. J. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.04.009 · Cited by 56
Mortality Following Defibrillator Implantation in Patients with Renal Insufficiency
Eckart, R. E., Gula, L. J., REYNOLDS, M. R., Shry, E. A., & Maisel, W. H. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00550.x · Cited by 55
Janardhan, A. H., Li, W., Fedorov, V. V., Yeung, M., Wallendorf, M., Schuessler, R. B., & Efimov, I. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.1001 · Cited by 54
The National ICD Registry: Now and into the future
Hammill, S. C., Phurrough, S. E., & Brindis, R. G. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.01.019 · Cited by 54
Antiarrhythmic agents and proarrhythmia
Chaudhry, G. M., & Haffajee, C. I. (2000) · Critical Care Medicine · doi:10.1097/00003246-200010001-00008 · Cited by 54
Nonthoracotomy Implantable Defibrillator Lead Extraction:
Saad, E., Saliba, W. I., Schweikert, R. A., Al-Khadra, A. S., Abdul‐Karim, A., Niebauer, M. J., & Wilkoff, B. L. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00300.x · Cited by 54
“To successfully extract NTLs using the superior vein approach, there was adherence to three important principles: (1) the”
MethodRisk stratification following myocardial infarction in the thrombolytic era
Andresen, D., Steinbeck, G., Brüggemann, T., Müller, D., Haberl, R., Behrens, S., Hoffmann, E., Wegscheider, K., Dißmann, R., & Ehlers, H.-C. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00516-6 · Cited by 61
Device Therapy in Heart Failure Patients With Chronic Kidney Disease
Cannizzaro, L., Piccini, J. P., Patel, U. D., & Hernandez, A. F. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.05.024 · Cited by 53
Gula, L. J., Ames, A., WOODBURN, A., MAtkins, J., McCORMICK, M., BELL, J., SINK, D., McConville, J. W., & Epstein, L. M. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00163.x · Cited by 53
de Bie, M. K., Lekkerkerker, J. C., van Dam, B., Gaasbeek, A., van Buren, M., Putter, H., van Erven, L., Bax, J. J., Schalij, M. J., Rabelink, T. J., et al. (2008) · Current Medical Research and Opinion · doi:10.1185/03007990802237343 · Cited by 55
Gula, L. J., Klein, G. J., Hellkamp, A. S., Massel, D. R., Krahn, A. D., Skanes, A. C., Yee, R. K., Anderson, J., Johnson, G. W., Poole, J. E., et al. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.08.007 · Cited by 55
Evolution of Cardiovascular Disease During the Transition to End-Stage Renal Disease
Bansal, N. (2017) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2016.12.002 · Cited by 54
Kusumoto, F. M., Bailey, K. R., Chaouki, A. S., Deshmukh, A. J., Gautam, S., Kim, R. J., Kramer, D. B., Lambrakos, L. K., Nasser, N. H., & Sorajja, D. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.052 · Cited by 55
Tjong, F. V. Y., & Koop, B. E. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0602-y · Cited by 57
New perspectives and future directions in the treatment of heart failure
Pellicori, P., Khan, M. J., Graham, F. J., & Cleland, J. G. F. (2019) · Heart Failure Reviews · doi:10.1007/s10741-019-09829-7 · Cited by 56
In situ diagnosis and simultaneous treatment of cardiac diseases using a single-device platform
Hwang, J. C., Kim, M., Kim, S., Seo, H., An, S., Jang, E. H., Han, S. Y., Kim, M. J., Kim, N. K., Cho, S., et al. (2022) · Science Advances · doi:10.1126/sciadv.abq0897 · Cited by 54
Interim analyses and sequential designs in phase III studies
Todd, S., Whitehead, A., Stallard, N., & Whitehead, J. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2001.01382.x · Cited by 60
Occhetta, E., Bortnik, M., Magnani, A., Francalacci, G., & Marino, P. N. (2006) · EP Europace · doi:10.1093/europace/eul093 · Cited by 53
Sudden Death Prevention With Implantable Devices
PASSMAN, R. S., & Kadish, A. H. (2007) · Circulation · doi:10.1161/circulationaha.106.655704 · Cited by 56
Advanced ICD Troubleshooting: Part II
Swerdlow, C. D., & Friedman, P. A. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00300.x · Cited by 54
Grubman, E. M., Pavri, B. B., Shipman, T., Britton, N., & Kocovic, D. Z. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00359-3 · Cited by 53
Gelfman, L. P., Kalman, J., & Goldstein, N. E. (2014) · Journal of Palliative Medicine · doi:10.1089/jpm.2013.0675 · Cited by 58
BAQUERO, G. A., BANCHS, J. E., DEPALMA, S., YOUNG, S. K., PENNY‐PETERSON, E. D., SAMII, S. M., WOLBRETTE, D. L., NACCARELLI, G. V., & GONZALEZ, M. D. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02183.x · Cited by 52
Shafee, M. A., Fukuda, K., Wakayama, Y., Nakano, M., Kondo, M., Hasebe, Y., Kawana, A., & Shimokawa, H. (2012) · Journal of Cardiology · doi:10.1016/j.jjcc.2012.08.002 · Cited by 53
LaPointe, N. M. A., Al‐Khatib, S. M., Piccini, J. P., Atwater, B. D., Honeycutt, E. F., Thomas, K. L., Shah, B. R., Zimmer, L. O., Sanders, G. D., & Peterson, E. D. (2011) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.958603 · Cited by 52
Honarbakhsh, S., Providencia, R. A., Srinivasan, N. T., Ahsan, S., LOWE, M. D., Rowland, E., Hunter, R., Finlay, M., Segal, O. R., Earley, M. J., et al. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.11.017 · Cited by 52
Implantable cardioverter defibrillators and their role in heart failure progression
Çevik, C., Perez-Verdia, A., & NUGENT, K. M. (2009) · EP Europace · doi:10.1093/europace/eup091 · Cited by 59
Chen, L., & Hay, J. W. (2004) · Cardiovascular Drugs and Therapy · doi:10.1023/b:card.0000029034.65769.f7 · Cited by 60
Worldwide Utilization of Implantable Cardioverter/Defibrillators Now and in the Future
Seidl, K., & Senges, J. (2003) · Cardiac Electrophysiology Review · doi:10.1023/a:1023603118860 · Cited by 52
Has the survival of the heart failure population changed? lessons from trials
Cleland, J. G. F., & Clark, A. L. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)01011-x · Cited by 58
KORHONEN, P., HUSA, T., TIERALA, I., VÄÄNÄNEN, H., MÄKIJÄRVI, M., KATILA, T., & TOIVONEN, L. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00332.x · Cited by 51
VAZQUEZ, L. D., CONTI, J. B., & SEARS, S. F. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02787.x · Cited by 51
“The FPAS is composed of four factors: (1) Return to Function, (2) Device-Related Distress, (3) Positive Appraisal, and (4) Body Image Concerns.”
BackgroundMartin, D. T., McNitt, S., Nesto, R. W., Rutter, M. K., & Moss, A. J. (2011) · Circulation Heart Failure · doi:10.1161/circheartfailure.110.959510 · Cited by 51
Self-citationNarins, C. R., Aktaş, M. K., Chen, A. Y., McNitt, S. A., Ling, F. S., Younis, A., Zaręba, W., Daubert, J. P., Huang, D. T.-C., Rosero, S. Z., et al. (2021) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2021.06.020 · Cited by 53
Self-citationDiretriz Brasileira de Dispositivos Cardíacos Eletrônicos Implantáveis – 2023
Teixeira, R. A., Fagundes, A. A., Baggio, J. M., de Oliveira, J. C., Medeiros, P. D. T. J., Valdigem, B. P., Teno, L. A. C., Silva, R. T., de Melo, C. S., Elías, J., et al. (2023) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20220892 · Cited by 71
Lip, G. Y. H., Heinzel, F. R., Gaïta, F., González‐Juanatey, J. R., Heuzey, J. Y. L., Potpara, T., Svendsen, J. H., Vos, M. A., Anker, S. D., Coats, A. J. S., et al. (2015) · European Journal of Heart Failure · doi:10.1002/ejhf.338 · Cited by 54
Prediction of Arrhythmic Events with Positron Emission Tomography: PAREPET study design and methods
Fallavollita, J. A., Luisi, A. J., Michalek, S. M., Valverde, A. M., deKemp, R. A., Haka, M. S., Hutson, A. D., & Canty, J. M. (2006) · Contemporary Clinical Trials · doi:10.1016/j.cct.2006.03.005 · Cited by 52
Cost-Effectiveness Analysis: A Proposal of New Reporting Standards in Statistical Analysis
Bang, H., & Zhao, H. (2014) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543406.2013.860157 · Cited by 58
Thijssen, J., Borleffs, C. J. W., van Rees, J. B., de Bie, M. K., van der Velde, E. T., van Erven, L., Bax, J. J., Cannegieter, S. C., & Schalij, M. J. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr161 · Cited by 51
Bernal, O., & Moro, C. (2006) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(07)60011-5 · Cited by 60
Arenal, Á., Proclemer, A., Kloppe, A., Lunati, M., Ferrer, J. M., Hersi, A. S., Gułaj, M., WIJFFELS, M. C. E. F., Santi, E., Manotta, L., et al. (2016) · EP Europace · doi:10.1093/europace/euw032 · Cited by 51
A 25‐year review of sequential methodology in clinical studies
Todd, S. (2006) · Statistics in Medicine · doi:10.1002/sim.2763 · Cited by 58
Perioperative cardiac arrhythmias
Thompson, A., & Balser, J. R. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh166 · Cited by 51
NACCARELLLI, G. V., Wolbrette, D. L., Dell’Orfano, J. T., Patel, H. M., & Luck, J. C. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00127.x · Cited by 52
Rosano, G. M. C., Stolfo, D., Anderson, L., Abdelhamid, M., Adamo, M., Bauersachs, J., Bayés‐Genís, A., Böhm, M., Chioncel, O. D., Filippatos, G. S., et al. (2024) · European Journal of Heart Failure · doi:10.1002/ejhf.3284 · Cited by 51
Saeed, M., NEASON, C., Razavi, M., CHANDIRAMANI, S., Alonso, J., NATARAJAN, S., IP, J. H., Peress, D., RAMADAS, S., & Massumi, A. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01825.x · Cited by 50
An Updated Review of Implantable Cardioverter/Defibrillators, Induced Anxiety, and Quality of Life
Bostwick, J. M., & Sola, C. L. (2010) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.10.003 · Cited by 54
Carroll, S. L., Strachan, P. H., de Laat, S., Schwartz, L. J., & Arthur, H. M. (2011) · Health Expectations · doi:10.1111/j.1369-7625.2011.00703.x · Cited by 54
Tsai, V., Goldstein, M. K., Hsia, H. H., Wang, Y., Curtis, J. P., & Heidenreich, P. A. (2011) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.959205 · Cited by 50
(2008), G. D. T. D. L. E. P. E. D. Y. T. D. L. I. C. A. Y. C., & Desarrollada en colaboración con la Heart Failure Association (HFA) de la ESC y aprobada por la European Society of Intensive Care Medicine (ESICM) (2008) · Revista Española de Cardiología · doi:10.1016/s0300-8932(08)75740-3 · Cited by 87
Wang, C. C., Wu, C., Tsai, M., Lee, C., Huang, W. C., Chou, H., Huang, J. L., Chi, N., Yen, H., Tzeng, B., et al. (2019) · PubMed Central · doi:10.6515/acs.201905_35(3).20190422a · Cited by 54
Okada, D. R., Miller, J., Chrispin, J., Prakosa, A., Trayanova, N. A., Jones, S., Maggioni, M., & Wu, K. C. (2020) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007975 · Cited by 52
Boriani, G., Lubinski, A., Capucci, A., Niederle, R., Kornacewicz-Jack, Z., Wnuk-Wojnar, A. M., Borggrefe, M., Brachmann, J., Biffi, M., & Butrous, G. S. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2679 · Cited by 51
Implantable cardioverter defibrillators and cardiac resynchronisation therapy
Holzmeister, J., & Leclercq, C. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61228-2 · Cited by 62
Systematic Review of Defibrillation Threshold Testing at De Novo Implantation
Phan, K. H., Ha, H., Kabunga, P., Kilborn, M. J., Toal, E., & Sy, R. W. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003357 · Cited by 49
Naksuk, N., Tan, N. Y. L., Padmanabhan, D., Kancharla, K., Makkar, N., Yogeswaran, V., Gaba, P., Kaginele, P., Riley, D. C., Sugrue, A. M., et al. (2018) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.117.006091 · Cited by 52
Cardiac Implantable Electronic Device Therapy
Steffen, M., Osborn, J. S., & Cutler, M. J. (2019) · Medical Clinics of North America · doi:10.1016/j.mcna.2019.04.005 · Cited by 54
Metadata
- Authors
- Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., Brown, M. W., & Heo, M.
- Affiliations
- University of Rochester Medicine (US)
- Good Samaritan Hospital (US)
- Scripps Memorial Hospital (US)
- University Hospital Magdeburg (DE)
- St. Francis Hospital (US)
- University Hospitals of Cleveland (US)
- University of Chicago (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1996-12-26
- Volume
- 335
- Issue
- 26
- Pages
- 1933-1940
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2320382602
- Cited by
- 4,165
- References
- 25
- Citations by year
- 2026: 40 · 2025: 61 · 2024: 54 · 2023: 61 · 2022: 97 · 2021: 70 · 2020: 85 · 2019: 98 · 2018: 106 · 2017: 151 · 2016: 145 · 2015: 136 · 2014: 145 · 2013: 154 · 2012: 171
- FWCI
- 93.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- implantable cardioverter-defibrillator, ventricular tachyarrhythmia, myocardial infarction, left ventricular dysfunction, survival, antiarrhythmic therapy, amiodarone, beta-blockers, high-risk patients
- MeSH terms
- Adult, Aged, Anti-Arrhythmia Agents, Coronary Disease, Female, Humans, Male, Middle Aged, Myocardial Infarction, Risk Factors, Proportional Hazards Models, Survival Analysis, Defibrillators, Implantable, Tachycardia, Ventricular, Ventricular Dysfunction, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.