Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 456

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

A Paclitaxel-Eluting Stent for the Prevention of Coronary Restenosis

Open access
Park, Seung-Jung, Shim, Won Heum, Ho, David S., Raizner, Albert E., Park, Seong-Wook, Hong, Myeong-Ki, Lee, Cheol Whan, Choi, Donghoon, Jang, Yangsoo, Lam, Ricky, Weissman, Neil J., Mintz, Gary S. · 2003 · New England Journal of Medicine

Abstract

BACKGROUND: Intimal hyperplasia and resulting restenosis limit the efficacy of coronary stenting. We studied a coronary stent coated with the antiproliferative agent paclitaxel as a means of preventing restenosis. METHODS: We conducted a multicenter, randomized, controlled, triple-blind study to evaluate the ability of a paclitaxel-eluting stent to inhibit restenosis. At three centers, 177 patients with discrete coronary lesions (<15 mm in length, 2.25 to 3.5 mm in diameter) underwent implantation of paclitaxel-eluting stents (low dose, 1.3 microg per square millimeter, or high dose, 3.1 microg per square millimeter) or control stents. Antiplatelet therapies included aspirin with ticlopidine (120 patients), clopidogrel (18 patients), or cilostazol (37 patients). Clinical follow-up was performed at one month and four to six months, and angiographic follow-up at four to six months. RESULTS: Technical success was achieved in 99 percent of the patients (176 of 177). At follow-up, the high-dose group, as compared with the control group, had significantly better results for the degree of stenosis (mean [+/-SD], 14+/-21 percent vs. 39+/-27 percent; P<0.001), late loss of luminal diameter (0.29+/-0.72 mm vs. 1.04+/-0.83 mm, P<0.001), and restenosis of more than 50 percent (4 percent vs. 27 percent, P<0.001). Intravascular ultrasound analysis demonstrated a dose-dependent reduction in the volume of intimal hyperplasia (31, 18, and 13 mm3, in the high-dose, low-dose, and control groups, respectively). There was a higher rate of major cardiac events in patients receiving cilostazol than in those receiving ticlopidine or clopidogrel. Among patients receiving ticlopidine or clopidogrel, event-free survival was 98 percent and 100 percent in the high-dose and control groups, respectively, at one month, and 96 percent in both at four to six months. CONCLUSIONS: Paclitaxel-eluting stents used with conventional antiplatelet therapy effectively inhibit restenosis and neointimal hyperplasia, with a safety profile similar to that of standard stents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa021007

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Park, S.-J., Shim, W. H., Ho, D. S., Raizner, A. E., Park, S.-W., Hong, M.-K., Lee, C. W., Choi, D., Jang, Y., Lam, R., Weissman, N. J., & Mintz, G. S.
Venue
New England Journal of Medicine
Published
2003-04-17
Volume
348
Issue
16
Pages
1537-1545
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2104337019
Cited by
456
References
17
FWCI
73.64
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.