The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Single Reading with Computer-Aided Detection for Screening Mammography
Abstract
BACKGROUND: The sensitivity of screening mammography for the detection of small breast cancers is higher when the mammogram is read by two readers rather than by a single reader. We conducted a trial to determine whether the performance of a single reader using a computer-aided detection system would match the performance achieved by two readers. METHODS: The trial was designed as an equivalence trial, with matched-pair comparisons between the cancer-detection rates achieved by single reading with computer-aided detection and those achieved by double reading. We randomly assigned 31,057 women undergoing routine screening by film mammography at three centers in England to double reading, single reading with computer-aided detection, or both double reading and single reading with computer-aided detection, at a ratio of 1:1:28. The primary outcome measures were the proportion of cancers detected according to regimen and the recall rates within the group receiving both reading regimens. RESULTS: The proportion of cancers detected was 199 of 227 (87.7%) for double reading and 198 of 227 (87.2%) for single reading with computer-aided detection (P=0.89). The overall recall rates were 3.4% for double reading and 3.9% for single reading with computer-aided detection; the difference between the rates was small but significant (P<0.001). The estimated sensitivity, specificity, and positive predictive value for single reading with computer-aided detection were 87.2%, 96.9%, and 18.0%, respectively. The corresponding values for double reading were 87.7%, 97.4%, and 21.1%. There were no significant differences between the pathological attributes of tumors detected by single reading with computer-aided detection alone and those of tumors detected by double reading alone. CONCLUSIONS: Single reading with computer-aided detection could be an alternative to double reading and could improve the rate of detection of cancer from screening mammograms read by a single reader. (ClinicalTrials.gov number, NCT00450359.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Note on the Sampling Error of the Difference Between Correlated Proportions or Percentages
McNemar, Q. (1947) · Psychometrika · doi:10.1007/bf02295996 · Cited by 4,754
Gallant, J. E. (2004) · JAMA · doi:10.1001/jama.292.2.191 · Cited by 1,341
Trials to assess equivalence: the importance of rigorous methods: Fig 1
Jones, B., Jarvis, P., Lewis, J. A., & Ebbutt, A. F. (1996) · BMJ · doi:10.1136/bmj.313.7048.36 · Cited by 1,032
Freer, T. W., & Ulissey, M. J. (2001) · Radiology · doi:10.1148/radiol.2203001282 · Cited by 751
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Potential Contribution of Computer-aided Detection to the Sensitivity of Screening Mammography
Warren Burhenne, L. J., Wood, S. A., D'Orsi, C. J., Feig, S. A., Kopans, D. B., O'Shaughnessy, K. F., Sickles, E. A., Tabar, L., Vyborny, C. J., & Castellino, R. A. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ma15554 · Cited by 554
Birdwell, R. L., Ikeda, D. M., O’Shaughnessy, K. F., & Sickles, E. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap16192 · Cited by 428
Comparison of Screening Mammography in the United States and the United Kingdom
Smith-Bindman, R. (2003) · JAMA · doi:10.1001/jama.290.16.2129 · Cited by 314
Gur, D., Sumkin, J. H., Rockette, H. E., Ganott, M., Hakim, C., Hardesty, L., Poller, W. R., Shah, R., & Wallace, L. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh067 · Cited by 306
Computer aided detection (CAD): an overview
Castellino, R. A. (2005) · Cancer Imaging · doi:10.1102/1470-7330.2005.0018 · Cited by 284
Statistical Issues in Drug Development
Ziegel, E. R., & Senn, S. (1999) · Technometrics · doi:10.2307/1271380 · Cited by 224
Screening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation
Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K. (2006) · Radiology · doi:10.1148/radiol.2392042121 · Cited by 218
Brem, R. F., Baum, J., Lechner, M., Kaplan, S., Souders, S., Naul, L. G., & Hoffmeister, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.3.1810687 · Cited by 189
Computer-aided Detection with Screening Mammography in a University Hospital Setting
Birdwell, R. L., Bandodkar, P., & Ikeda, D. M. (2005) · Radiology · doi:10.1148/radiol.2362040864 · Cited by 187
Current status and future directions of computer-aided diagnosis in mammography
Nishikawa, R. M. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.009 · Cited by 175
Dean, J. C., & Ilvento, C. C. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0111 · Cited by 163
Taylor, P. M., & POTTS, H. W. W. (2008) · European Journal of Cancer · doi:10.1016/j.ejca.2008.02.016 · Cited by 160
Khoo, L. A. L., Taylor, P. M., & Given-Wilson, R. (2005) · Radiology · doi:10.1148/radiol.2372041362 · Cited by 149
Gromet, M. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2812 · Cited by 147
Impact of Computer-Aided Detection in a Regional Screening Mammography Program
Cupples, T. E., Cunningham, J. E., & Reynolds, J. C. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.04.1300 · Cited by 147
Blanks, R. G., Wallis, M., & Moss, S. (1998) · Journal of Medical Screening · doi:10.1136/jms.5.4.195 · Cited by 137
Self-citationHuo, Z., Giger, M. L., Vyborny, C. J., & Metz, C. E. (2002) · Radiology · doi:10.1148/radiol.2242010703 · Cited by 133
Computer-aided Detection versus Independent Double Reading of Masses on Mammograms
Karssemeijer, N., Otten, J. D. M., Verbeek, A. L. M., Groenewoud, J. H., de Koning, H. J., Hendriks, J. H. C. L., & Holland, R. (2003) · Radiology · doi:10.1148/radiol.2271011962 · Cited by 127
Destounis, S. V., DiNitto, P. A., Logan-Young, W. W., Bonaccio, E., Zuley, M. L., & Willison, K. M. (2004) · Radiology · doi:10.1148/radiol.2322030034 · Cited by 124
Prospective Assessment of Computer-Aided Detection in Interpretation of Screening Mammography
Ko, J., Nicholas, M. J., Mendel, J. B., & Slanetz, P. J. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.1582 · Cited by 122
Double reading of mammography screening films-one radiologist or two?
Anttinen, I., Pamilo, M., Soiva, M., & Roiha, M. (1993) · Clinical Radiology · doi:10.1016/s0009-9260(05)81111-0 · Cited by 118
Computer-aided detection in mammography
Astley, S., & Gilbert, F. J. (2004) · Clinical Radiology · doi:10.1016/j.crad.2003.11.017 · Cited by 101
Self-citationGilbert, F. J., Astley, S., McGee, M. A., Gillan, M. G., Boggis, C. R. M., Griffiths, P. M., & Duffy, S. W. (2006) · Radiology · doi:10.1148/radiol.2411051092 · Cited by 97
Self-citationCiatto, S., Turco, M. R. D., Risso, G. G., Catarzi, S., Bonardi, R., Viterbo, V., Gnutti, P., Guglielmoni, B., Pinelli, L., Pandiscia, A., et al. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00011-6 · Cited by 85
Ikeda, D. M., Birdwell, R. L., O′Shaughnessy, K. F., Sickles, E. A., & Brenner, R. J. (2004) · Radiology · doi:10.1148/radiol.2303030254 · Cited by 73
Blanks, R. G., Wallis, M., & Given-Wilson, R. (1999) · Journal of Medical Screening · doi:10.1136/jms.6.3.152 · Cited by 60
Self-citationBrem, R. F., & Schoonjans, J. M. (2001) · Clinical Radiology · doi:10.1053/crad.2000.0592 · Cited by 54
Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography
Georgian-Smith, D., Moore, R. H., Halpern, E. F., Yeh, E. D., Rafferty, E. A., D’Alessandro, H. A., Staffa, M., Hall, D. A., McCarthy, K. A., & Kopans, D. B. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2393 · Cited by 53
Computed assisted detection of interval breast cancers
Moberg, K., Bjurstam, N., Wilczek, B., Rostgård-Christensen, L., Egge, E., & Muren, C. (2001) · European Journal of Radiology · doi:10.1016/s0720-048x(01)00291-1 · Cited by 52
Sensitivity and specificity of computer-assisted breast cancer detection in mammography screening
Thurfjell, E., Thurfjell, M. G., Egge, E., & Bjurstam, N. (1998) · Acta Radiologica · doi:10.1080/02841859809172450 · Cited by 52
CAD for mammography: the technique, results, current role and further developments
Malich, A., Fischer, D. R., & Böttcher, J. (2006) · European Radiology · doi:10.1007/s00330-005-0089-x · Cited by 44
Breast Cancer Detection Rate: Designing Imaging Trials to Demonstrate Improvements
Jiang, Y., Miglioretti, D. L., Metz, C. E., & Schmidt, R. A. (2007) · Radiology · doi:10.1148/radiol.2432060253 · Cited by 35
One-Day Quadruple Therapy Compared With 7-Day Triple Therapy for Helicobacter pylori Infection
Lara, L. F., Cisneros, G., Gurney, M. A., Ness, M. V., Jarjoura, D. G., Moauro, B., Polen, A., Rutecki, G. W., & Whittier, F. C. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.17.2079 · Cited by 34
Computer-aided Detection of Breast Cancer: A Cost-effectiveness Study
Lindfors, K. K., McGahan, M. C., Rosenquist, C. J., & Hurlock, G. (2006) · Radiology · doi:10.1148/radiol.2392050670 · Cited by 31
Can the NHS Breast Screening Programme Afford not to Double Read Screening Mammograms?
Liston, J. C., & Dall, B. J. G. (2003) · Clinical Radiology · doi:10.1016/s0009-9260(03)00063-1 · Cited by 18
Computer-Aided Screening Mammography
Ciatto, S., & Houssami, N. (2007) · New England Journal of Medicine · doi:10.1056/nejmc071248 · Cited by 16
Cited by
Predicting the future - big data, machine learning, and clinical medicine
Obermeyer, Z., & Emanuel, E. J. (2016) · New England Journal of Medicine · doi:10.1056/nejmp1606181 · Cited by 3,652
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Self-citationDeep Learning in Medical Image Analysis
Chan, H.-P., Samala, R. K., Hadjiiski, L. M., & Zhou, C. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-030-33128-3_1 · Cited by 747
Detecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Self-citation
Metadata
- Authors
- Gilbert, F. J., Astley, S. M., Gillan, M. G. C., Agbaje, O. F., Wallis, M. G., James, J., Boggis, C. R. M., & Duffy, S. W.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2008-10-16
- Volume
- 359
- Issue
- 16
- Pages
- 1675-1684
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2020506948
- Cited by
- 296
- References
- 41
- FWCI
- 21.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.