The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Noise processes in nanomechanical resonators
Abstract
Nanomechanical resonators can be fabricated to achieve high natural resonance frequencies, approaching 1 GHz, with quality factors in excess of 104. These resonators are candidates for use as highly selective rf filters and as precision on-chip clocks. Some fundamental and some nonfundamental noise processes will present limits to the performance of such resonators. These include thermomechanical noise, Nyquist–Johnson noise, and adsorption–desorption noise; other important noise sources include those due to thermal fluctuations and defect motion-induced noise. In this article, we develop a self-contained formalism for treating these noise sources, and use it to estimate the impact that these noise processes will have on the noise of a model nanoscale resonator, consisting of a doubly clamped beam of single-crystal Si with a natural resonance frequency of 1 GHz.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vibration problems in engineering
Timoshenko, S. P. (1928) · CERN Document Server (European Organization for Nuclear Research) · Cited by 3,449
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Anelastic Relaxation in Crystalline Solids
Nowick, A. S., Berry, B. S., & Katz, J. L. (1975) · Journal of Applied Mechanics · doi:10.1115/1.3423694 · Cited by 2,622
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Zangwill, A. (1988) · Cambridge University Press eBooks · doi:10.1017/cbo9780511622564 · Cited by 1,999
Thermoelastic damping in micro- and nanomechanical systems
Lifshitz, R., & Roukes, M. L. (2000) · Physical review. B, Condensed matter · doi:10.1103/physrevb.61.5600 · Cited by 1,231
Self-citationThe intrinsic thermal conductivity of AIN
Slack, G. A., Tanzilli, R. A., Pohl, R. O., & Vandersande, J. W. (1987) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(87)90153-3 · Cited by 1,009
Quality factors in micron- and submicron-thick cantilevers
Yasumura, K. Y., Stowe, T. D., Chow, E. M., Pfafman, T. E., Kenny, T. W., Stipe, B. C., & Rugar, D. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825786 · Cited by 688
Fabrication of high frequency nanometer scale mechanical resonators from bulk Si crystals
Cleland, A. N., & Roukes, M. L. (1996) · Applied Physics Letters · doi:10.1063/1.117548 · Cited by 538
Self-citationA nanometre-scale mechanical electrometer
Cleland, A. N., & Roukes, M. L. (1998) · Nature · doi:10.1038/32373 · Cited by 512
Self-citationStructural relaxation and defect annihilation in pure amorphous silicon
Roorda, S., Sinke, W. C., Poate, J. M., Jacobson, D. C., Dierker, S., Dennis, B. S., Eaglesham, D. J., Spaepen, F., & Fuoss, P. (1991) · Physical Review B · doi:10.1103/physrevb.44.3702 · Cited by 408
Some aspects of the theory and measurement of frequency fluctuations in frequency standards
Cutler, L. S., & Searle, C. L. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4627 · Cited by 395
Robins, W. P. (1984) · Institution of Engineering and Technology eBooks · doi:10.1049/pbte009e · Cited by 370
VHF free-free beam high-Q micromechanical resonators
Wang, K., Wong, A.-C., & Nguyen, C. T. ‐. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.870061 · Cited by 365
Frequency synthesis by phase lock
Egan, W. F. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 232
Fundamental limits on the frequency stabilities of crystal oscillators
Walls, F. L., & Vig, J. R. (1995) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.393101 · Cited by 144
An efficient algorithm to compute Allan variance from spectral density
Egan, W. F. (1988) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.6059 · Cited by 14
Cited by
Ekinci, K. L., & Roukes, M. L. (2005) · Review of Scientific Instruments · doi:10.1063/1.1927327 · Cited by 1,374
Self-citationCantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Zeptogram-Scale Nanomechanical Mass Sensing
Yang, Y. T., Callegari, C., Feng, X. L., Ekinci, K. L., & Roukes, M. L. (2006) · Nano Letters · doi:10.1021/nl052134m · Cited by 1,041
Self-citationUltrahigh-Density Nanowire Lattices and Circuits
Melosh, N. A., Boukai, A., Diana, F., Gerardot, B., Badolato, A., Petroff, P. M., & Heath, J. R. (2003) · Science · doi:10.1126/science.1081940 · Cited by 883
Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
Ekinci, K. L., Yang, Y. T., & Roukes, M. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1642738 · Cited by 695
Self-citation
Metadata
- Authors
- Cleland, A. N., & Roukes, M. L.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2002-09-01
- Volume
- 92
- Issue
- 5
- Pages
- 2758-2769
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1979563351
- Cited by
- 461
- References
- 17
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.