Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record.

True atomic resolution in liquid by frequency-modulation atomic force microscopy

Open access
Fukuma, Takeshi, Kobayashi, Kei, Matsushige, Kazumi, Yamada, Hirofumi·2005·Applied Physics Letters

Abstract

True atomic resolution of frequency-modulation atomic force microscopy in liquid is demonstrated. Hexagonal lattice of a cleaved (001) surface of muscovite mica is resolved in water. Nonperiodic structures such as defects and adsorbates are simultaneously imaged with the atomic-scale features of mica surface. The use of small oscillation amplitude (0.16–0.33 nm) of a force sensing cantilever allows us to obtain vertical and lateral resolutions of 2–6 and 300 pm, respectively, even with a low Q factor in water (Q=20–30).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.1999856

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 21

  1. 1991, J. Appl. Phys., 69, 668, 10.1063/1.347347 · DOI · Paper page
  2. 1982, Phys. Rev. Lett., 49, 57, 10.1103/PhysRevLett.49.57 · DOI · Paper page
  3. 1986, Phys. Rev. Lett., 56, 930, 10.1103/PhysRevLett.56.930 · DOI · Paper page
  4. 1997, Probe Microsc., 1, 3
  5. 1995, Science, 267, 68, 10.1126/science.267.5194.68 · DOI · Paper page
  6. 1995, Jpn. J. Appl. Phys., Part 2, 34, L1086, 10.1143/JJAP.34.L1086 · doi:10.1143/jjap.34.l1086
  7. 1997, Chem. Phys. Lett., 280, 296, 10.1016/S0009-2614(97)01143-3 · DOI
  8. 1999, Appl. Surf. Sci., 140, 243, 10.1016/S0169-4332(98)00534-0 · doi:10.1016/s0169-4332(98)00534-0
  9. 1999, Appl. Surf. Sci., 140, 287, 10.1016/S0169-4332(98)00542-X · doi:10.1016/s0169-4332(98)00542-x
  10. 1994, Appl. Phys. Lett., 64, 1738, 10.1063/1.111795 · DOI · Paper page
  11. 1994, Appl. Phys. Lett., 64, 2454, 10.1063/1.111597 · DOI · Paper page
  12. 2005, Appl. Phys. Lett., 86, 034103, 10.1063/1.1852721 · doi:10.1063/1.1852721
  13. 2005, Appl. Phys. Lett., 86, 193108, 10.1063/1.1925780 · doi:10.1063/1.1925780
  14. 2005, Rev. Sci. Instrum., 76, 053704, 10.1063/1.1896938 · DOI · Paper page
  15. 1999, Appl. Surf. Sci., 140, 352, 10.1016/S0169-4332(98)00553-4 · doi:10.1016/s0169-4332(98)00553-4
  16. 2000, Science, 289, 422, 10.1126/science.289.5478.422 · DOI · Paper page
  17. 1988, J. Chem. Phys., 89, 5190, 10.1063/1.455608 · DOI · Paper page
  18. 1989, Science, 243, 1586, 10.1126/science.2928794 · DOI · Paper page
  19. 1995, Phys. Rev. B, 52, R8692, 10.1103/PhysRevB.52.R8692 · DOI
  20. 2000, J. Phys. Chem., 104, 6091, 10.1021/jp001616d · DOI · Paper page
  21. Morita, 2002, Noncontact Atomic Force Microscopy Nanoscience and Technology, 10.1007/978-3-642-56019-4 · DOI · Paper page

Cited by

See all 375

Metadata

Authors
Fukuma, T., Kobayashi, K., Matsushige, K., & Yamada, H.
Venue
Applied Physics Letters
Published
2005-07-12
Volume
87
Issue
3
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W1987858867
Cited by
375
References
0
FWCI
7.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: True atomic resolution in liquid by frequency-modulation atomic force microscopy. https://app.cochat.ai/papers/10.1063/1.1999856
The paper
Fukuma, T., Kobayashi, K., Matsushige, K., & Yamada, H. (2005). True atomic resolution in liquid by frequency-modulation atomic force microscopy. Applied Physics Letters. https://doi.org/10.1063/1.1999856

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.