Thermal conductivities and phase transition temperatures of various phase-change materials measured by the 3ω method
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We have employed the “3ω method” to determine the thermal conductivities of the amorphous and crystalline phases of the technologically important materials Ge2Sb2Te5, nitrogen-doped Ge2Sb2Te5, Ag- and In-doped Sb2Te, and Ge15Sb85. We used the “3ω voltage” as a monitor of thermal conductivity that allowed us to observe the amorphous-to-crystalline phase transition as the material was annealed. For these materials, our results reveal that the thermal conductivity κ is related to the electrical conductivity σ by an empirical relationship of the form κ=σLT+0.175 W/m K, where L is the Lorenz number and T is temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928
Thermal conductivity of a -Si:H thin films
Cahill, D. G., Katiyar, M., & Abelson, J. R. (1994) · Physical Review B · doi:10.1103/physrevb.50.6077 · Cited by 523
Cahill, D. G. (2002) · Review of Scientific Instruments · doi:10.1063/1.1505652 · Cited by 118
Cited by
Wong, H.-S. P., Raoux, S., Kim, S., Liang, J., Reifenberg, J. P., Rajendran, B., Asheghi, M., & Goodson, K. E. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2070050 · Cited by 1,806
Self-citationNanoscale thermal transport. II. 2003–2012
Cahill, D. G., Braun, P. V., Chen, G., Clarke, D. R., Fan, S., Goodson, K. E., Keblinski, P., King, W. P., Mahan, G. D., Majumdar, A., et al. (2014) · Applied Physics Reviews · doi:10.1063/1.4832615 · Cited by 1,763
Phase change memory technology
Burr, G. W., Breitwisch, M. J., Franceschini, M., Garetto, D., Gopalakrishnan, K., Jackson, B., Kurdi, B., Lam, C., Lastras, L. A., Padilla, A., et al. (2010) · Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena · doi:10.1116/1.3301579 · Cited by 916
Self-citationDesign Rules for Phase‐Change Materials in Data Storage Applications
Lencer, D., Salinga, M., & Wuttig, M. (2011) · Advanced Materials · doi:10.1002/adma.201004255 · Cited by 524
Raoux, S. (2009) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-082908-145405 · Cited by 439
Self-citationPalacios, A., Cong, L., Navarro, M. E., Ding, Y., & Barreneche, C. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.03.020 · Cited by 237
Measurement of crystal growth velocity in a melt-quenched phase-change material
Salinga, M., Carria, E., Kaldenbach, A., Bornhöfft, M., Benke, J., Mayer, J., & Wuttig, M. (2013) · Nature Communications · doi:10.1038/ncomms3371 · Cited by 215
“As phase-change materials themselves typically show a comparably low thermal conductivity 16 , fast quenching is only possible by effectively draining off the heat into neighbouring materials.”
Femtosecond x-ray diffraction reveals a liquid–liquid phase transition in phase-change materials
Zalden, P., Quirin, F., Schumacher, M., Siegel, J., Wei, S., Koc, A., Nicoul, M., Trigo, M., Andreasson, P., Enquist, H., et al. (2019) · Science · doi:10.1126/science.aaw1773 · Cited by 168
Thermal Conductivity Anisotropy and Grain Structure in Ge2Sb2Te5 Films
Lee, J., Li, Z., Reifenberg, J. P., Lee, S., Sinclair, R., Asheghi, M., & Goodson, K. E. (2011) · Journal of Applied Physics · doi:10.1063/1.3573505 · Cited by 85
Metadata
- Authors
- Risk, W. P., Rettner, C. T., & Raoux, S.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2009-03-09
- Volume
- 94
- Issue
- 10
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2056593988
- Cited by
- 70
- References
- 3
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.