The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Open accessAbstract
We describe an ultrasensitive atomic magnetometer based on optically pumped potassium atoms operating in a spin-exchange relaxation free regime. We demonstrate magnetic field sensitivity of 160 aT/Hz1/2 in a gradiometer arrangement with a measurement volume of 0.45 cm3 and energy resolution per unit bandwidth of 44ℏ. As an example of an application enabled by such a magnetometer, we describe measurements of weak remnant rock magnetization as a function of temperature with a sensitivity on the order of 10−10 emu/cm3/Hz1/2 and temperatures up to 420°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationSingle spin detection by magnetic resonance force microscopy
Rugar, D., Budakian, R., Mamin, H. J., & Chui, B. W. (2004) · Nature · doi:10.1038/nature02658 · Cited by 1,630
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,444
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationPaleomagnetic Principles and Practice
(2003) · Modern Approaches in Geophysics · doi:10.1007/0-306-48128-6 · Cited by 470
High-temperature weak ferromagnetism in a low-density free-electron gas
Young, D. P., Hall, D., Torelli, M. E., Fisk, Z., Sarrao, J. L., Thompson, J. D., Ott, H.-R., Oseroff, S. B., Goodrich, R. G., & Zysler, R. (1999) · Nature · doi:10.1038/17081 · Cited by 430
Ultrasensitive magnetic biosensor for homogeneous immunoassay
Chemla, Y. R., Grossman, H. L., Poon, Y., McDermott, R., Stevens, R., Alper, M. D., & Clarke, J. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.26.14268 · Cited by 421
Highly Sensitive and Easy-to-Use SQUID Sensors
Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T. (2007) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2007.897403 · Cited by 348
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Quantum metrology and its application in biology
Taylor, M. A., & Bowen, W. P. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.002 · Cited by 470
Electric dipole moments of atoms, molecules, nuclei, and particles
Chupp, T. E., Fierlinger, P., Ramsey-Musolf, M. J., & Singh, J. T. (2019) · Reviews of Modern Physics · doi:10.1103/revmodphys.91.015001 · Cited by 450
Quantum-enhanced measurements without entanglement
Braun, D., Adesso, G., Benatti, F., Floreanini, R., Marzolino, U., Mitchell, M. W., & Pirandola, S. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035006 · Cited by 434
Subpicotesla Diamond Magnetometry
Wolf, T., Neumann, P., Nakamura, K., Sumiya, H., Ohshima, T., Isoya, J., & Wrachtrup, J. (2015) · Physical Review X · doi:10.1103/physrevx.5.041001 · Cited by 378
Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Self-citationProposal for a Cosmic Axion Spin Precession Experiment (CASPEr)
Budker, D., Graham, P. W., Ledbetter, M., Rajendran, S., & Sushkov, A. O. (2014) · Physical Review X · doi:10.1103/physrevx.4.021030 · Cited by 355
Kitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Cavity Optomechanical Magnetometer
Forstner, S., Prams, S., Knittel, J., van Ooijen, E. D., Swaim, J. D., Harris, G. I., Szorkovszky, A., Bowen, W. P., & Rubinsztein-Dunlop, H. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.120801 · Cited by 303
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
Self-citationScalable Spin Squeezing for Quantum-Enhanced Magnetometry with Bose-Einstein Condensates
Muessel, W., Strobel, H., Linnemann, D., Hume, D. B., & Oberthaler, M. K. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.103004 · Cited by 254
Li, B.-B., Ou, L., Lei, Y., & Liu, Y.-C. (2021) · Nanophotonics · doi:10.1515/nanoph-2021-0256 · Cited by 251
Optical Fiber Magnetic Field Sensors Based on Magnetic Fluid: A Review
Alberto, N., Domingues, M. F., Marques, C., André, P. S. D. B., & Antunes, P. F. D. C. (2018) · Sensors · doi:10.3390/s18124325 · Cited by 213
Magnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer
Johnson, C., Schwindt, P. D. D., & Weisend, M. (2010) · Applied Physics Letters · doi:10.1063/1.3522648 · Cited by 210
Toward Quantitative Bio-sensing with Nitrogen–Vacancy Center in Diamond
Zhang, T., Pramanik, G., Zhang, K., Gulka, M., Wang, L., Jing, J., Xu, F., Li, Z., Wei, Q., Cigler, P., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00415 · Cited by 208
Search for axion-like dark matter with ferromagnets
Gramolin, A. V., Aybas, D., Johnson, D., Adam, J., & Sushkov, A. O. (2020) · Nature Physics · doi:10.1038/s41567-020-1006-6 · Cited by 203
On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194
All-Optical Vector Atomic Magnetometer
Patton, B., Zhivun, E., Hovde, D. C., & Budker, D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.013001 · Cited by 185
Femtotesla atomic magnetometry in a microfabricated vapor cell
Griffith, W. C., Knappe, S., & Kitching, J. (2010) · Optics Express · doi:10.1364/oe.18.027167 · Cited by 183
A tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180
A microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179
Quantum technology for military applications
Krelina, M. (2021) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-021-00113-y · Cited by 176
A low-power, high-sensitivity micromachined optical magnetometer
Mhaskar, R., Knappe, S., & Kitching, J. (2012) · Applied Physics Letters · doi:10.1063/1.4770361 · Cited by 171
Integrated and Portable Magnetometer Based on Nitrogen‐Vacancy Ensembles in Diamond
Stürner, F. M., Brenneis, A., Buck, T., Kassel, J., Rölver, R., Fuchs, T., Savitsky, A., Suter, D., Grimmel, J., Hengesbach, S., et al. (2021) · Advanced Quantum Technologies · doi:10.1002/qute.202000111 · Cited by 165
Parahydrogen-enhanced zero-field nuclear magnetic resonance
Theis, T., Ganssle, P., Kervern, G., Knappe, S., Kitching, J., Ledbetter, M. P., Budker, D., & Pines, A. (2011) · Nature Physics · doi:10.1038/nphys1986 · Cited by 165
Full-Field Terahertz Imaging at Kilohertz Frame Rates Using Atomic Vapor
Downes, L. A., MacKellar, A. R., Whiting, D. J., Bourgenot, C. J., Adams, C. S., & Weatherill, K. J. (2020) · Physical Review X · doi:10.1103/physrevx.10.011027 · Cited by 185
SERF Atomic Magnetometer–Recent Advances and Applications: A Review
Li, J., Quan, W., Zhou, B., Wang, Z., Lu, J., Hu, Z., Liu, G., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2863707 · Cited by 166
Light storage for one second in room-temperature alkali vapor
Katz, O., & Firstenberg, O. (2018) · Nature Communications · doi:10.1038/s41467-018-04458-4 · Cited by 151
Four-channel optically pumped atomic magnetometer for magnetoencephalography
Colombo, A. P., Carter, T. R., Borna, A., Jau, Y., Johnson, C., Dagel, A. L., & Schwindt, P. D. D. (2016) · Optics Express · doi:10.1364/oe.24.015403 · Cited by 162
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
Review: Quantum metrology and sensing with many-body systems
Montenegro, V., Mukhopadhyay, C., Yousefjani, R., Sarkar, S., Mishra, U., Paris, M. G. A., & Bayat, A. (2025) · Physics Reports · doi:10.1016/j.physrep.2025.05.005 · Cited by 244
Precision Magnetometers for Aerospace Applications: A Review
Bennett, J. S., Vyhnalek, B. E., Greenall, H., Bridge, E. M., Gotardo, F., Forstner, S., Harris, G. I., Miranda, F. A., & Bowen, W. P. (2021) · Sensors · doi:10.3390/s21165568 · Cited by 145
Colloquium : Quantum limits to the energy resolution of magnetic field sensors
Mitchell, M. W., & Palacios, S. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.021001 · Cited by 148
A new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array
Yang, Y., Xu, M., Liang, A., Yin, Y., Ma, X., Gao, Y., & Ning, X. (2021) · Scientific Reports · doi:10.1038/s41598-021-84971-7 · Cited by 146
Ultrasensitive Optomechanical Magnetometry
Forstner, S., Sheridan, E., Knittel, J., Humphreys, C. L., Brawley, G. A., Rubinsztein-Dunlop, H. H., & Bowen, W. P. (2014) · Advanced Materials · doi:10.1002/adma.201401144 · Cited by 133
Multi-sensor magnetoencephalography with atomic magnetometers
Johnson, C., Schwindt, P. D. D., & Weisend, M. P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/17/6065 · Cited by 144
Magnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array
Wyllie, R., Kauer, M., Smetana, G., Wakai, R. T., & Walker, T. G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2619 · Cited by 140
An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device
Storm, J.-H., Hömmen, P., Drung, D., & Körber, R. (2017) · Applied Physics Letters · doi:10.1063/1.4976823 · Cited by 129
Magnetic field imaging with microfabricated optically-pumped magnetometers
Alem, O., Mhaskar, R. R., Jiménez-Martínez, R., Sheng, D., LeBlanc, J., Trahms, L., Sander, T. H., Kitching, J. E., & Knappe, S. A. (2017) · Optics Express · doi:10.1364/oe.25.007849 · Cited by 126
Knappe, S. A., Sander, T. H., Kosch, O., Wiekhorst, F., Kitching, J. E., & Trahms, L. (2010) · Applied Physics Letters · doi:10.1063/1.3491548 · Cited by 130
Sensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Tang, J., Zhai, Y., Li, C., Zhang, Y., Li, L., Zhao, B., Zhou, B., Han, B., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.425851 · Cited by 125
Diamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement
Zhang, C., Shagieva, F., Widmann, M., Kübler, M., Vorobyov, V., Kapitanova, P., Nenasheva, E., Corkill, R., Rhrle, O., Nakamura, K., et al. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.064075 · Cited by 136
Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell
Scholtes, T., Schultze, V., IJsselsteijn, R. P. J., Woetzel, S., & Meyer, H. ‐. (2011) · Physical Review A · doi:10.1103/physreva.84.043416 · Cited by 127
Measurement-induced, spatially-extended entanglement in a hot, strongly-interacting atomic system
Kong, J., Jiménez-Martínez, R., Troullinou, C., Lucivero, V. G., Tóth, G., & Mitchell, M. W. (2020) · Nature Communications · doi:10.1038/s41467-020-15899-1 · Cited by 136
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
Comagnetometer probes of dark matter and new physics
Terrano, W. A., & Romalis, M. V. (2021) · Quantum Science and Technology · doi:10.1088/2058-9565/ac1ae0 · Cited by 128
Self-citationLee, J., Ding, R., Christensen, J., Rosenthal, R. R., Ison, A. M., Gillund, D., Bossert, D., Fuerschbach, K., Kindel, W., Finnegan, P. S., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31410-4 · Cited by 122
Pustelny, S., Kimball, D. F. J., Pankow, C., Ledbetter, M. P., Wlodarczyk, P., Wcisło, P., Pospelov, M., Smith, J. R., Read, J., Gawlik, W., et al. (2013) · Annalen der Physik · doi:10.1002/andp.201300061 · Cited by 128
Quantum‐Based Magnetic Field Sensors for Biosensing
Bao, B., Hua, Y., Wang, R., & Li, D. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202200146 · Cited by 108
Exceptional magnetic sensitivity of P T -symmetric cavity magnon polaritons
Cao, Y., & Yan, P. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.99.214415 · Cited by 110
Integrated Optically Pumped Magnetometer for Measurements within Earth’s Magnetic Field
Oelsner, G., IJsselsteijn, R. P. J., Scholtes, T., Krüger, A., Schultze, V., Seyffert, G., Werner, G. R., Jäger, M., Chwala, A., & Stolz, R. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.024034 · Cited by 105
New constraints on axion-like dark matter using a Floquet quantum detector
Bloch, I. M., Ronen, G., Shaham, R., Katz, O., Tomer Volansky, A., & Katz, O. (2022) · Science Advances · doi:10.1126/sciadv.abl8919 · Cited by 100
Constraints on axion-like dark matter from a SERF comagnetometer
Bloch, I. M., Shaham, R., Hochberg, Y., Kuflik, E., Tomer Volansky, A., & Katz, O. (2023) · Nature Communications · doi:10.1038/s41467-023-41162-4 · Cited by 100
Ultralow Mechanical Damping with Meissner-Levitated Ferromagnetic Microparticles
Vinante, A., Falferi, P., Gasbarri, G., Setter, A., Timberlake, C., & Ulbricht, H. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.13.064027 · Cited by 99
Parameter Modeling Analysis of a Cylindrical Ferrite Magnetic Shield to Reduce Magnetic Noise
Ma, D., Lu, J., Fang, X., Yang, K., Wang, K., Zhang, N., Han, B., & Ding, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050351 · Cited by 99
Tang, J., Zhai, Y., Zhou, B., Han, B., & Liu, G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3112797 · Cited by 102
Ultrasensitive magnetic field detection using a single artificial atom
Bal, M., Deng, C., Orgiazzi, J.-L., Ong, F. R., & Lupaşcu, A. (2012) · Nature Communications · doi:10.1038/ncomms2332 · Cited by 91
Hu, Y., Iwata, G. Z., Mohammadi, M., Silletta, E. V., Wickenbrock, A., Blanchard, J. W., Budker, D., & Jerschow, A. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1917172117 · Cited by 90
Rydberg atom electric field sensing for metrology, communication and hybrid quantum systems
Zhang, H., Ma, Y., Liao, K.-Y., Yang, W., Liu, Z., 丁冬生, Yan, H., Li, W., & Zhang, L. (2024) · 中国科学通报:英文版 · doi:10.1016/j.scib.2024.03.032 · Cited by 85
Tang, J., Liu, Y., Wang, Y., Zhou, B., Han, B., Zhai, Y., & Liu, G. (2022) · Applied Physics Letters · doi:10.1063/5.0080764 · Cited by 85
Improving cold-atom sensors with quantum entanglement: Prospects and challenges
Szigeti, S. S., Hosten, O., & Haine, S. A. (2021) · Applied Physics Letters · doi:10.1063/5.0050235 · Cited by 89
Precessing Ferromagnetic Needle Magnetometer
Kimball, D. F. J., Sushkov, A. O., & Budker, D. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.190801 · Cited by 98
Magnetoencephalography with a Cs-based high-sensitivity compact atomic magnetometer
Sheng, J., Wan, S., Sun, Y., Dou, R., Guo, Y., Wei, K., He, K., Qin, J., & Gao, J. (2017) · Review of Scientific Instruments · doi:10.1063/1.5001730 · Cited by 84
Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Sulai, I. A., DeLand, Z. J., Bulatowicz, M. D., Wahl, C. P., Wakai, R. T., & Walker, T. G. (2019) · Review of Scientific Instruments · doi:10.1063/1.5091007 · Cited by 79
Simultaneous tracking of spin angle and amplitude beyond classical limits
Colangelo, G., Ciurana, F. M., Bianchet, L. C., Sewell, R. J., & Mitchell, M. W. (2017) · Nature · doi:10.1038/nature21434 · Cited by 79
Continuous High-Sensitivity and High-Bandwidth Atomic Magnetometer
Li, R., Baynes, F. N., Luiten, A. N., & Perrella, C. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.064067 · Cited by 78
Single-beam three-axis atomic magnetometer
Huang, H., Dong, H., Chen, L., & Gao, Y. (2016) · Applied Physics Letters · doi:10.1063/1.4960971 · Cited by 79
Atomic magnetometers for materials characterization
Romalis, M. V., & Dang, H. B. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70140-7 · Cited by 83
Self-citationMa, N., Fang, X., Zhang, Y., Xing, B., Duan, L., Lu, J., Han, B., & Ma, D. (2024) · Optics Express · doi:10.1364/oe.530764 · Cited by 77
Ito, Y., Sato, D., Kamada, K., & Kobayashi, T. (2016) · Optics Express · doi:10.1364/oe.24.015391 · Cited by 79
Jodko-Władzińska, A., Wildner, K., Pałko, T., & Władziński, M. (2020) · Sensors · doi:10.3390/s20164563 · Cited by 76
Femtotesla Direct Magnetic Gradiometer Using a Single Multipass Cell
Lucivero, V. G., Lee, W., Dural, N., & Romalis, M. V. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.014004 · Cited by 77
Self-citationWang, T., Kimball, D. F. J., Sushkov, A. O., Aybas, D., Blanchard, J. W., Centers, G., O’Kelley, S. R., Wickenbrock, A., Fang, J., & Budker, D. (2017) · Physics of the Dark Universe · doi:10.1016/j.dark.2017.11.003 · Cited by 79
Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell
Ma, Y., Chen, Y., Yu, M., Wang, Y., Lu, S., Guo, J., Luo, G., Zhao, L., Yang, P., Lin, Q., et al. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00758-6 · Cited by 79
Optomechanical Magnetometry with a Macroscopic Resonator
Yu, C., Janoušek, J., Sheridan, E., McAuslan, D. L., Rubinsztein-Dunlop, H. H., Lam, P. K., Zhang, Y., & Bowen, W. P. (2016) · Physical Review Applied · doi:10.1103/physrevapplied.5.044007 · Cited by 72
Troullinou, C., Jiménez-Martínez, R., Kong, J., Lucivero, V. G., & Mitchell, M. W. (2021) · Physical Review Letters · doi:10.1103/physrevlett.127.193601 · Cited by 2
Widefield microwave imaging in alkali vapor cells with sub-100μm resolution
Horsley, A., Du, G.-X., & Treutlein, P. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/11/112002 · Cited by 77
Duan, L., Fang, J., Li, R., Jiang, L., Ding, M., & Wang, W. (2015) · Optics Express · doi:10.1364/oe.23.032481 · Cited by 71
Bao, G., Wickenbrock, A., Rochester, S., Zhang, W., & Budker, D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.033202 · Cited by 71
Krzyzewski, S., Perry, A. R., Gerginov, V. P., & Knappe, S. A. (2019) · Journal of Applied Physics · doi:10.1063/1.5098088 · Cited by 72
Free-Induction-Decay Magnetometer Based on a Microfabricated Cs Vapor Cell
Hunter, D., Piccolomo, S., Pritchard, J. D., Brockie, N. L., Dyer, T., & Riis, E. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.014002 · Cited by 70
Superconducting sensors and methods in geophysical applications
Stolz, R., Schmelz, M., Zakosarenko, V., Foley, C., Tanabe, K., Xie, X., & Fagaly, R. L. (2021) · Superconductor Science and Technology · doi:10.1088/1361-6668/abd7ce · Cited by 82
High-Resolution Zero-Field NMR J-Spectroscopy of Aromatic Compounds
Blanchard, J. W., Ledbetter, M. P., Theis, T., Butler, M. C., Budker, D., & Pines, A. (2013) · Journal of the American Chemical Society · doi:10.1021/ja312239v · Cited by 76
Entanglement-Based dc Magnetometry with Separated Ions
Ruster, T., Kaufmann, H., Luda, M. A., Kaushal, V., Schmiegelow, C. T., Schmidt‐Kaler, F., & Poschinger, U. (2017) · Physical Review X · doi:10.1103/physrevx.7.031050 · Cited by 74
Fang, J., Wang, T., Quan, W., Yuan, H., Zhang, H., Li, Y., & Zou, S. (2014) · Review of Scientific Instruments · doi:10.1063/1.4881685 · Cited by 72
Fang, J., & Qin, J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4756046 · Cited by 73
Seltzer, S. J., Michalak, D. J., Donaldson, M. H., Balabas, M. V., Barber, S., Bernasek, S. L., Bouchiat, M.-A., Hexemer, A., Hibberd, A. M., Kimball, D. F. J., et al. (2010) · The Journal of Chemical Physics · doi:10.1063/1.3489922 · Cited by 69
Zhao, J., Ding, M., Lu, J., Yang, K., Ma, D., Yao, H., Han, B., & Liu, G. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2905308 · Cited by 70
Methods for measuring the electron’s electric dipole moment using ultracold YbF molecules
Fitch, N. J., Lim, J., Hinds, E. A., Sauer, B. E., & Tarbutt, M. R. (2020) · Quantum Science and Technology · doi:10.1088/2058-9565/abc931 · Cited by 68
Suppression of the Bias Error Induced by Magnetic Noise in a Spin-Exchange Relaxation-Free Gyroscope
Fan, W., Quan, W., Liu, F., Li, X., & Liu, G. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2929505 · Cited by 67
Recent Progress of Atomic Magnetometers for Geomagnetic Applications
Lu, Y., Zhao, T., Zhu, W., Liu, L., Zhuang, X., Fang, G., & Zhang, X. (2023) · Sensors · doi:10.3390/s23115318 · Cited by 71
He, K., Wan, S., Sheng, J., Liu, D., Wang, C., Li, D., Qin, L., Luo, S., Qin, J., & Gao, J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5066250 · Cited by 71
Polymer encapsulated microcavity optomechanical magnetometer
Zhu, J., Zhao, G., Savukov, I., & Yang, L. (2017) · Scientific Reports · doi:10.1038/s41598-017-08875-1 · Cited by 64
Metadata
- Authors
- Dang, H. B., Maloof, A. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Maloof, A. C.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2010-10-11
- Volume
- 97
- Issue
- 15
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2131775935
- Cited by
- 891
- References
- 24
- Citations by year
- 2026: 69 · 2025: 110 · 2024: 104 · 2023: 107 · 2022: 94 · 2021: 77 · 2020: 55 · 2019: 67 · 2018: 34 · 2017: 33 · 2016: 30 · 2015: 26 · 2014: 18 · 2013: 23 · 2012: 25
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Applied Physics Letters (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- atomic magnetometer, spin-exchange relaxation-free, magnetic field sensitivity, energy resolution, temperature dependence of magnetization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.