The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
High-throughput size-based rare cell enrichment using microscale vortices
Open accessAbstract
Cell isolation in designated regions or from heterogeneous samples is often required for many microfluidic cell-based assays. However, current techniques have either limited throughput or are incapable of viable off-chip collection. We present an innovative approach, allowing high-throughput and label-free cell isolation and enrichment from heterogeneous solution using cell size as a biomarker. The approach utilizes the irreversible migration of particles into microscale vortices, developed in parallel expansion-contraction trapping reservoirs, as the cell isolation mechanism. We empirically determined the critical particle/cell diameter Dcrt and the operational flow rate above which trapping of cells/particles in microvortices is initiated. Using this approach we successfully separated larger cancer cells spiked in blood from the smaller blood cells with processing rates as high as 7.5×106 cells/s. Viable long-term culture was established using cells collected off-chip, suggesting that the proposed technique would be useful for clinical and research applications in which in vitro culture is often desired. The presented technology improves on current technology by enriching cells based on size without clogging mechanical filters, employing only a simple single-layered microfluidic device and processing cell solutions at the ml/min scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Laflamme, M. A., Chen, K. Y., Naumova, A. V., Muskheli, V., Fugate, J. A., Dupras, S. K., Reinecke, H., Xu, C., Hassanipour, M., Police, S., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1327 · Cited by 2,206
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Self-citationViscous and resistive eddies near a sharp corner
Moffatt, H. K. (1964) · Journal of Fluid Mechanics · doi:10.1017/s0022112064000015 · Cited by 1,531
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Self-citationYamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599
Deformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Self-citationEquilibrium Separation and Filtration of Particles Using Differential Inertial Focusing
Di Carlo, D., Edd, J. F., Irimia, D., Tompkins, R. G., & Toner, M. (2008) · Analytical Chemistry · doi:10.1021/ac702283m · Cited by 413
Self-citationSheathless inertial cell ordering for extreme throughput flow cytometry
Hur, S. C., Tse, H. T. K., & Di Carlo, D. (2010) · Lab Chip · doi:10.1039/b919495a · Cited by 368
Self-citationA rare-cell detector for cancer
Krivacic, R. T., Ladanyi, A., Curry, D. N., Hsieh, H. B., Kuhn, P., Bergsrud, D. E., Kepros, J. F., Barbera, T., Ho, M. Y., Chen, L. B., et al. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404036101 · Cited by 340
Continuous scalable blood filtration device using inertial microfluidics
Mach, A. J., & Di Carlo, D. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22833 · Cited by 334
Self-citationCirculating tumor cell clusters in the peripheral blood of colorectal cancer patients.
Molnar, B. A., Ladányi, A., Tanko, L. M., Sreter, L., & Tulassay, Z. (2001) · PubMed · Cited by 241
Transgenic Enrichment of Cardiomyocytes From Human Embryonic Stem Cells
Anderson, D., Self, T., Mellor, I. R., Goh, G., Hill, S. J., & Denning, C. (2007) · Molecular Therapy · doi:10.1038/sj.mt.6300303 · Cited by 231
Huang, R., Barber, T. A., Schmidt, M. A., Tompkins, R. G., Toner, M., Bianchi, D. W., Kapur, R., & Flejter, W. L. (2008) · Prenatal Diagnosis · doi:10.1002/pd.2079 · Cited by 158
Park, J.-S., & Jung, H. (2009) · Analytical Chemistry · doi:10.1021/ac9005765 · Cited by 155
Flow behaviour of blood cells and rigid spheres in an annular vortex
Takeshi Karino, A., & Goldsmith, H. L. (1977) · Philosophical transactions of the Royal Society of London. Series B, Biological sciences · doi:10.1098/rstb.1977.0095 · Cited by 119
Deterministic Lateral Displacement as a Means to Enrich Large Cells for Tissue Engineering
Green, J. V., Radisic, M., & Murthy, S. K. (2009) · Analytical Chemistry · doi:10.1021/ac9018395 · Cited by 91
The human embryonic stem cell-derived cardiomyocyte as a pharmacological model
Harding, S. E., Ali, N. N., Brito-Martins, M., & Gorelik, J. (2007) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2006.08.008 · Cited by 84
Marrinucci, D. C., Bethel, K. J., Luttgen, M. S., Bruce, R. H., Nieva, J. J., & Kühn, P. (2009) · Archives of Pathology & Laboratory Medicine · doi:10.5858/133.9.1468 · Cited by 82
Trapping of Bioparticles via Microvortices in a Microfluidic Device for Bioassay Applications
Lin, C. M., Lai, Y. S., Liu, H. P., Chen, C. Y., & Wo, A. M. (2008) · Analytical Chemistry · doi:10.1021/ac800972t · Cited by 66
Taylor, M., Rössler, J. K., Geoerger, B., Laplanche, A., Hartmann, O., Vassal, G., & Farace, F. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-2363 · Cited by 65
Cell Docking in Double Grooves in a Microfluidic Channel
Khabiry, M., Chung, B. G., HANCOCK, M. J., Soundararajan, H. C., Du, Y., Cropek, D. M., Lee, W. G., & Khademhosseini, A. (2009) · Small · doi:10.1002/smll.200801644 · Cited by 53
Cha, D. H., Khosrotehrani, K., Bianchi, D. W., & Johnson, K. L. (2005) · Prenatal Diagnosis · doi:10.1002/pd.1199 · Cited by 15
Growth potential of the cells of permanent lines (HeLa, BHK/21, NRK)
Rafferty, K. A. (1986) · Virchows Archiv B Cell Pathology Including Molecular Pathology · doi:10.1007/bf02889899 · Cited by 6
Cited by
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Isolation and retrieval of circulating tumor cells using centrifugal forces
Hou, H. W., Warkiani, M. E., Khoo, B. L., Li, Z. R., Soo, R. A., Tan, D. S.-W., Lim, W.-T., Han, J., Bhagat, A. A. S., & Lim, C. T. (2013) · Scientific Reports · doi:10.1038/srep01259 · Cited by 736
Inertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Size-selective collection of circulating tumor cells using Vortex technology
Sollier, E., Go, D. E., Che, J., Gossett, D. R., O'Byrne, S., Weaver, W. M., Kummer, N., Rettig, M., Goldman, J., Nickols, N., et al. (2014) · Lab Chip · doi:10.1039/c3lc50689d · Cited by 498
Self-citationFundamentals of inertial focusing in microchannels
Zhou, J., & Papautsky, I. (2013) · Lab on a Chip · doi:10.1039/c2lc41248a · Cited by 446
Metadata
- Authors
- Hur, S. C., Mach, A. J., & Di Carlo, D.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2011-06-01
- Volume
- 5
- Issue
- 2
- Pages
- 22206-22206
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2037714118
- Cited by
- 317
- References
- 28
- FWCI
- 16.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.