The DOI matches its Crossref record.
How the size distribution of magnetic nanoparticles determines their magnetic particle imaging performance
Abstract
Spatial and temporal resolution of magnetic particle imaging (MPI), a powerful technique for biomedical imaging, depends crucially on the magnetic properties of the magnetic nanoparticle (MNP) tracer. The authors establish the relation of the static and the dynamic magnetization behavior of various MNP preparations to their MPI performance. While MNPs with a mean diameter of 6 nm achieve only 0.2% of the theoretical maximum amplitude of the third harmonic (at 25 kA/m drive field strength), those with 19 nm diameter attain 57%. The good performance of Resovist, a clinically approved contrast agent for magnetic resonance imaging, is explained by the presence of MNP aggregates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Recent advances in magnetic nanoparticle-based multi-modal imaging
Shin, T.-H., Choi, Y., Kim, S., & Cheon, J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00345d · Cited by 602
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Advances in the Application of Magnetic Nanoparticles for Sensing
Gloag, L., Mehdipour, M., Chen, D., Tilley, R. D., & Gooding, J. J. (2019) · Advanced Materials · doi:10.1002/adma.201904385 · Cited by 364
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
Zheng, B., Vazin, T., Goodwill, P. W., Conway, A., Verma, A., Ulku Saritas, E., Schaffer, D., & Conolly, S. M. (2015) · Scientific Reports · doi:10.1038/srep14055 · Cited by 274
Magnetic particle imaging with tailored iron oxide nanoparticle tracers
Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Arami, H., Saritas, E. U., Croft, L. R., Konkle, J., Goodwill, P. W., Halkola, A., Rahmer, J., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2375065 · Cited by 222
Pablico-Lansigan, M. H., Situ, S. F., & Samia, A. C. S. (2013) · Nanoscale · doi:10.1039/c3nr00544e · Cited by 172
Monodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging
Khandhar, A. P., Ferguson, R. M., Arami, H., & Krishnan, K. M. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.087 · Cited by 152
“4 a TEM characterization data from [26], which provides extensive characterization of Resovist.”
BackgroundKratz, H., Taupitz, M., Ariza de Schellenberger, A., Kosch, O., Eberbeck, D., Wagner, S., Trahms, L., Hamm, B., & Schnorr, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190214 · Cited by 92
Self-citationFirst in vivo traveling wave magnetic particle imaging of a beating mouse heart
Vogel, P., Rückert, M. A., Klauer, P., Kullmann, W. H., Jakob, P. M., & Behr, V. C. (2016) · Physics in Medicine & Biology · doi:10.1088/0031-9155/61/18/6620 · Cited by 60
Nanoparticles Unveiled: Key Characteristics and Properties of Multifunctional Magnetic Nanoparticles
Serdaroğlu, G. (2025) · Multifunctional Magnetic Nanoparticles in Analytical and Environmental Chemistry · doi:10.1039/9781837675357-00083 · Cited by 1
Metadata
- Authors
- Eberbeck, D., Wiekhorst, F., Wagner, S., & Trahms, L.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2011-05-02
- Volume
- 98
- Issue
- 18
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2015976998
- Cited by
- 192
- References
- 0
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.