The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Studies of vibrating atomic force microscope cantilevers in liquid
Abstract
An atomic force microscope (AFM) design providing a focused spot of order 7 μm in diameter was used to analyze the motion of vibrating cantilevers in liquid. Picking an operating frequency for tapping mode AFM operation in liquid is complex because there is typically a large number of sharp peaks in the response spectrum of cantilever slope amplitude versus drive frequency. The response spectrum was found to be a product of the cantilever’s broad thermal noise spectrum and an underlying fluid drive spectrum containing the sharp peaks. The geometrical shape of transverse cantilever motion was qualitatively independent of the fluid drive spectrum and could be approximately reproduced by a simple theoretical model. The measurements performed give new insights into the behavior of cantilevers during tapping mode AFM operation in liquid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Vibration problems in engineering
Timoshenko, S. P. (1928) · CERN Document Server (European Organization for Nuclear Research) · Cited by 3,449
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Tapping mode atomic force microscopy in liquids
Hansma, P. K., Cleveland, J. P., Radmacher, M., Walters, D. A., Hillner, P. E., Bezanilla, M., Fritz, M., Vie, D., Hansma, H. G., Prater, C. B., et al. (1994) · Applied Physics Letters · doi:10.1063/1.111795 · Cited by 875
Self-citationScanning force microscopy - With Applications to Electric, Magnetic and Atomic Forces
Sarid, D., Coratger, R., Ajustron, F., & Beauvillain, J. (1991) · Microscopy Microanalysis Microstructures · doi:10.1051/mmm:0199100206064900 · Cited by 563
Tapping mode atomic force microscopy in liquid
Putman, C. A. J., Van der Werf, K. O., De Grooth, B. G., Van Hulst, N. F., & Greve, J. (1994) · Applied Physics Letters · doi:10.1063/1.111597 · Cited by 545
Direct Observation of Enzyme Activity with the Atomic Force Microscope
Radmacher, M., Fritz, M., Hansma, H. G., & Hansma, P. K. (1994) · Science · doi:10.1126/science.8079171 · Cited by 405
Self-citationScan speed limit in atomic force microscopy
BUTT, H. ‐., SIEDLE, P., SEIFERT, K., FENDLER, K., SEEGER, T., BAMBERG, E., WEISENHORN, A. L., GOLDIE, K., & ENGEL, A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03280.x · Cited by 233
Putman, C. A., van der Werf, K. O., de Grooth, B. G., van Hulst, N. F., & Greve, J. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80649-6 · Cited by 218
Motion and enzymatic degradation of DNA in the atomic force microscope
Bezanilla, M., Drake, B., Nudler, E., Kashlev, M., Hansma, P. K., & Hansma, H. G. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80733-7 · Cited by 215
Self-citationFritz, M., Radmacher, M., Cleveland, J. P., Allersma, M. W., Stewart, R. J., Gieselmann, R., Janmey, P. A., Schmidt, C. F., & Hansma, P. K. (1995) · Langmuir · doi:10.1021/la00009a040 · Cited by 147
Self-citationForces affecting the substrate in resonant tapping force microscopy
Spatz, J. P., Sheiko, S. S., Möller, M., et al. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/2/002 · Cited by 135
Cited by
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
A high-speed atomic force microscope for studying biological macromolecules
Ando, T., Kodera, N., Takai, E., Maruyama, D., Saito, K., & Toda, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.211400898 · Cited by 1,102
High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes
Ando, T., Uchihashi, T., & Fukuma, T. (2008) · Progress in Surface Science · doi:10.1016/j.progsurf.2008.09.001 · Cited by 558
High-speed atomic force microscopy coming of age
Ando, T. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/6/062001 · Cited by 355
Metadata
- Authors
- Schäffer, T. E., Cleveland, J. P., Ohnesorge, F., Walters, D. A., & Hansma, P. K.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1996-10-01
- Volume
- 80
- Issue
- 7
- Pages
- 3622-3627
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2162791692
- Cited by
- 311
- References
- 13
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.