The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Experimental validation of theoretical models for the frequency response of atomic force microscope cantilever beams immersed in fluids
Open accessAbstract
Detailed measurements of the frequency responses of a series of rectangular atomic force microscope (AFM) cantilever beams, immersed in a range of fluids, have been performed to test the validity and accuracy of the recent theoretical model of Sader [J. Appl. Phys. 84, 64 (1998)]. This theoretical model gives the frequency response of a cantilever beam, that is immersed in a viscous fluid and excited by an arbitrary driving force. Very good agreement between experimental measurements and theoretical calculations is found for all fluids considered. Furthermore, a critical assessment of the well-known inviscid model is presented, which demonstrates that this model is not applicable to AFM cantilever beams in general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Self-citationMethod for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Self-citationMicrofabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Studies of vibrating atomic force microscope cantilevers in liquid
Schäffer, T. E., Cleveland, J. P., Ohnesorge, F., Walters, D. A., & Hansma, P. K. (1996) · Journal of Applied Physics · doi:10.1063/1.363308 · Cited by 311
Scan speed limit in atomic force microscopy
BUTT, H. ‐., SIEDLE, P., SEIFERT, K., FENDLER, K., SEEGER, T., BAMBERG, E., WEISENHORN, A. L., GOLDIE, K., & ENGEL, A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03280.x · Cited by 233
Characterization of application-specific probes for SPMs:
Tortonese, M., & Kirk, M. (1997) · SPIE Proceedings · doi:10.1117/12.271229 · Cited by 181
Distance-dependent noise measurements in scanning force microscopy
Roters, A., & Johannsmann, D. (1996) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/8/41/006 · Cited by 86
Cited by
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Metadata
- Authors
- Chon, J. W. M., Mulvaney, P., & Sader, J. E.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2000-04-15
- Volume
- 87
- Issue
- 8
- Pages
- 3978-3988
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2084403547
- Cited by
- 338
- References
- 10
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.