Plasma-assisted atomic layer deposition of Al2O3 and parylene C bi-layer encapsulation for chronic implantable electronics
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Encapsulation of biomedical implants with complex three dimensional geometries is one of the greatest challenges achieving long-term functionality and stability. This report presents an encapsulation scheme that combines Al(2)O(3) by atomic layer deposition with parylene C for implantable electronic systems. The Al(2)O(3)-parylene C bi-layer was used to encapsulate interdigitated electrodes, which were tested invitro by soak testing in phosphate buffered saline solution at body temperature (37 °C) and elevated temperatures (57 °C and 67 °C) for accelerated lifetime testing up to 5 months. Leakage current and electrochemical impedance spectroscopy were measured for evaluating the integrity and insulation performance of the coating. Leakage current was stably about 15 pA at 5 V dc, and impedance was constantly about 3.5 MΩ at 1 kHz by using electrochemical impedance spectroscopy for samples under 67 °C about 5 months (approximately equivalent to 40 months at 37 °C). Alumina and parylene coating lasted at least 3 times longer than parylene coated samples tested at 80 °C. The excellent insulation performance of the encapsulation shows its potential usefulness for chronic implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Integrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165
Self-citationThe insulation performance of reactive parylene films in implantable electronic devices
Seymour, J. P., Elkasabi, Y. M., Chen, H.-Y., Lahann, J., & Kipke, D. R. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.061 · Cited by 147
Cited by
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Fang, H., Zhao, J., Yu, K. J., Song, E., Farimani, A. B., Chiang, C.-H., Jin, X., Xue, Y., Xu, D., Du, W., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605269113 · Cited by 225
Mariello, M., Kim, K., Wu, K., Lacour, S. P., & Leterrier, Y. (2022) · Advanced Materials · doi:10.1002/adma.202201129 · Cited by 195
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
Self-citationRecent advances in materials and flexible electronics for peripheral nerve interfaces
Bettinger, C. J. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0007-6 · Cited by 77
Li, C., Cauwe, M., Yang, Y., Schaubroeck, D., Mader, L., & Op de Beeck, M. (2019) · Coatings · doi:10.3390/coatings9090579 · Cited by 46
“Despite the biocompatibility and good mechanical properties, one major disadvantage of these polymers for encapsulation is their low hermeticity towards moisture and water [11,12].”
Approaches to a cortical vision prosthesis: implications of electrode size and placement
Christie, B. P., Ashmont, K. R., House, P. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/025003 · Cited by 26
Metadata
- Authors
- Xie, X., Rieth, L., Merugu, S., Tathireddy, P., & Solzbacher, F.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2012-08-27
- Volume
- 101
- Issue
- 9
- Pages
- 093702
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2000577838
- Cited by
- 75
- References
- 2
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.