Approaches to a cortical vision prosthesis: implications of electrode size and placement
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
Objective. In order to move forward with the development of a cortical vision prosthesis, the critical issues in the field must be identified. Approach. To begin this process, we performed a brief review of several different cortical and retinal stimulation techniques that can be used to restore vision. Main results. Intracortical microelectrodes and epicortical macroelectrodes have been evaluated as the basis of a vision prosthesis. We concluded that an important knowledge gap necessitates an experimental in vivo performance evaluation of microelectrodes placed on the surface of the visual cortex. A comparison of the level of vision restored by intracortical versus epicortical microstimulation is necessary. Because foveal representation in the primary visual cortex involves more cortical columns per degree of visual field than does peripheral vision, restoration of foveal vision may require a large number of closely spaced microelectrodes. Based on previous studies of epicortical macrostimulation, it is possible that stimulation via surface microelectrodes could produce a lower spatial resolution, making them better suited for restoring peripheral vision. Significance. The validation of epicortical microstimulation in addition to the comparison of epicortical and intracortical approaches for vision restoration will fill an important knowledge gap and may have important implications for surgical strategies and device longevity. It is possible that the best approach to vision restoration will utilize both epicortical and intracortical microstimulation approaches, applying them appropriately to different visual representations in the primary visual cortex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In addition, these large electrodes interacted with relatively large volumes of cortex (∼1 cm3), resulting in very low spatial resolution of the perceived phosphenes (Christie et al., 2016; Niketeghad et al., 2019).”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Christie et al., 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global estimates of visual impairment: 2010
Pascolini, D., & Mariotti, S. P. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-300539 · Cited by 3,763
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 1×
“meaning that over a short time interval there is zero net charge injected into the tissue [11].”
BackgroundElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“The proliferation of astrocytes and glial scar formation can cause cell bodies to be pushed away from electrode recording sites [26], which may contribute to the decline in single unit activity that can be recorded over time [27].”
BackgroundCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 4×
“The Argus II allowed blind individuals to perform object localization, motion discrimination, and discrimination of oriented gratings [59].”
BackgroundMethodInfluentialSyringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Decoding motor imagery from the posterior parietal cortex of a tetraplegic human
Aflalo, T., Kellis, S., Klaes, C., Lee, B., Shi, Y., Pejsa, K., Shanfield, K., Hayes-Jackson, S., Aisen, M., Heck, C., et al. (2015) · Science · doi:10.1126/science.aaa5417 · Cited by 649
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600 · cited 1×
“stimulation, cracks occurred in the parylene-C insulation, which has been reported as a potential failure mode [39].”
Background
Cited by
Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans
Beauchamp, M. S., Oswalt, D., Sun, P., Foster, B. L., Magnotti, J. F., Niketeghad, S., Pouratian, N., Bosking, W. H., & Yoshor, D. (2020) · Cell · doi:10.1016/j.cell.2020.04.033 · Cited by 257
“This has inspired hope for the development of a visual cortical prosthetic (VCP), a device that would bypass the eyes and optic nerve, transmitting visual information from a camera directly into the visual cortex (Bosking et al., 2017a; Brindley and Lewin, 1968; Christie et al., 2016; Lewis et al., 2015, 2016; Najarpo…”
MethodCaldwell, R., Street, M. G., Sharma, R., Takmakov, P., Baker, B., & Rieth, L. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119731 · Cited by 100
Welle, E. J., Patel, P. R., Woods, J. E., Petrossians, A., della Valle, E., Vega-Medina, A., Richie, J. M., Cai, D., Weiland, J. D., & Chestek, C. A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8343 · Cited by 72
Fernández, E., Alfaro, A., & González-López, P. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00681 · Cited by 35
“In addition, these large electrodes interacted with relatively large volumes of cortex (∼1 cm3), resulting in very low spatial resolution of the perceived phosphenes (Christie et al., 2016; Niketeghad et al., 2019).”
BackgroundOswalt, D., Bosking, W., Sun, P., Sheth, S. A., Niketeghad, S., Salas, M. A., Patel, U., Greenberg, R., Dorn, J., Pouratian, N., et al. (2021) · Brain Stimulation · doi:10.1016/j.brs.2021.08.024 · Cited by 40
Metadata
- Authors
- Christie, B. P., Ashmont, K. R., House, P. A., & Greger, B.
- Affiliations
- Arizona State University (US)
- University of Utah (US)
- Corresponding author
- Greger, Bradley
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-02-23
- Volume
- 13
- Issue
- 2
- Pages
- 025003
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2288591390
- Cited by
- 26
- References
- 67
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 6 · 2019: 4 · 2018: 1 · 2017: 1 · 2016: 1
- FWCI
- 0.26
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- Research to Prevent Blindness
- Telemedicine and Advanced Technology Research Center
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- intracortical microelectrodes, microstimulation, macrostimulation, primary visual cortex, foveal vision, peripheral vision, spatial resolution, electrode size, electrode placement, retinal stimulation, vision restoration
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Visual, Humans, Microelectrodes, Vision Disorders, Visual Cortex, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Approaches to a cortical vision prosthesis: implications of electrode size and placement. https://app.cochat.ai/papers/10.1088/1741-2560/13/2/025003
- The paper
- Christie, B. P., Ashmont, K. R., House, P. A., & Greger, B. (2016). Approaches to a cortical vision prosthesis: implications of electrode size and placement. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/13/2/025003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.