A microfluidic device for uniform-sized cell spheroids formation, culture, harvesting and flow cytometry analysis
Open accessThe DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.
Abstract
Culture of cells as three-dimensional (3D) aggregates, named spheroids, possesses great potential to improve in vitro cell models for basic biomedical research. However, such cell spheroid models are often complicated, cumbersome, and expensive compared to conventional Petri-dish cell cultures. In this work, we developed a simple microfluidic device for cell spheroid formation, culture, and harvesting. Using this device, cells could form uniformly sized spheroids due to strong cell–cell interactions and the spatial confinement of microfluidic culture chambers. We demonstrated cell spheroid formation and culture in the designed devices using embryonic stem cells, carcinoma cells, and fibroblasts. We further scaled up the device capable of simultaneously forming and culturing 5000 spheroids in a single chip. Finally, we demonstrated harvesting of the cultured spheroids from the device with a simple setup. The harvested spheroids possess great integrity, and the cells can be exploited for further flow cytometry assays due to the ample cell numbers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While intravital imaging has proven extremely useful in the study of metastasis[6–7], it requires specialized expertise and equipment, and high image resolution is harder to attain in some visceral organs due to the depth of their location.”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [6]
In the citing paper
“For example, retrieving cells from microfluidic devices for subsequent biochemical studies is possible but not straightforward [6].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [6]
In the citing paper
“A number of groups were able to generate spheroids in chip-based devices171–173, but the spheroids lack spatial complexity and cell types compared to fully-developed organoids.”
From Towards organoid culture without Matrigel (2021) · cites this paper as [171]
Citations
Cites
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Cell and environment interactions in tumor microregions: the multicell spheroid model.
Sutherland, R. M. (1988) · Science · doi:10.1126/science.2451290 · Cited by 1,803
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Self-citationBartosh, T. J., Ylöstalo, J. H., Mohammadipoor, A., Bazhanov, N., Coble, K., Claypool, K., Lee, R. H., Choi, H., & Prockop, D. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1008117107 · Cited by 958
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
Experimental anti-tumor therapy in 3-D: Spheroids – old hat or new challenge?
Friedrich, J., Ebner, R., & Kunz-Schughart, L. A. (2007) · International Journal of Radiation Biology · doi:10.1080/09553000701727531 · Cited by 446
Fabrication of microfluidic devices using polydimethylsiloxane
Friend, J., & Yeo, L. (2010) · Biomicrofluidics · doi:10.1063/1.3259624 · Cited by 425
Research works printed but not linked: 2
- 2007, Biochip. J., 1, 17
- 2008, Introduction to Particle Technology
Cited by
Towards organoid culture without Matrigel
Kozlowski, M. T., Crook, C. J., & Ku, H. T. (2021) · Communications Biology · doi:10.1038/s42003-021-02910-8 · Cited by 409
Hydrogel microenvironments for cancer spheroid growth and drug screening
Li, Y., & Kumacheva, E. (2018) · Science Advances · doi:10.1126/sciadv.aas8998 · Cited by 351
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Engineering Multi‐Cellular Spheroids for Tissue Engineering and Regenerative Medicine
Kim, S., Kim, E. M., Yamamoto, M., Park, H., & Shin, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000608 · Cited by 234
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
Amaral, R. L. F., Miranda, M., Marcato, P. D., & Swiech, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00605 · Cited by 222
“However, small spheroids are inappropriate for creating a pathophysiological condition, since they do not develop chemical or proliferative gradients (Larue et al., 2004; Hardelauf et al., 2011; Patra et al., 2013).”
BackgroundPatra, B., Peng, C.-C., Liao, W.-H., Lee, C.-H., & Tung, Y.-C. (2016) · Scientific Reports · doi:10.1038/srep21061 · Cited by 215
Self-citationMicro-dissected tumor tissues on chip: an ex vivo method for drug testing and personalized therapy
Astolfi, M., Péant, B., Lateef, M. A., Rousset, N., Kendall-Dupont, J., Carmona, E., Monet, F., Saad, F., Provencher, D., Mes-Masson, A.-M., et al. (2016) · Lab on a Chip · doi:10.1039/c5lc01108f · Cited by 182
Biomaterials‐Based Approaches to Tumor Spheroid and Organoid Modeling
Thakuri, P. S., Liu, C., Luker, G. D., & Tavana, H. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700980 · Cited by 138
Chen, Y.-C., Lou, X., Zhang, Z., Ingram, P., & Yoon, E. (2015) · Scientific Reports · doi:10.1038/srep12175 · Cited by 136
Self-citationMulholland, T., McAllister, M., Patek, S., Flint, D., Underwood, M., Sim, A., Edwards, J., & Zagnoni, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-33055-0 · Cited by 132
Microfluidic Technology for the Generation of Cell Spheroids and Their Applications
Vadivelu, R., Kamble, H., Shiddiky, M., & Nguyen, N.-T. (2017) · Micromachines · doi:10.3390/mi8040094 · Cited by 132
“The grand challenge for MSC generation is maximizing the cell density in a small volume and generating a spheroids with the size smaller than 150 μm [34].”
BackgroundRuppen, J., Wildhaber, F. D., Strub, C., Hall, S. R. R., Schmid, R. A., Geiser, T., & Guenat, O. T. (2015) · Lab on a Chip · doi:10.1039/c5lc00454c · Cited by 127
Lee, Y. B., Kim, E. M., Byun, H., Chang, H.-K., Jeong, K., Aman, Z. M., Choi, Y. S., Park, J., & Shin, H. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.049 · Cited by 115
Advancements in 3D Cell Culture Systems for Personalizing Anti-Cancer Therapies
Law, A. M. K., de la Fuente, L. R., Grundy, T. J., Fang, G., Valdés‐Mora, F., & Gallego‐Ortega, D. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.782766 · Cited by 119
Engineered Microsystems for Spheroid and Organoid Studies
Kang, S., Kim, D., Lee, J., Takayama, S., & Park, J. Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001284 · Cited by 100
Dadgar, N., Gonzalez-Suarez, A. M., Fattahi, P., Hou, X., Weroha, J. S., Gaspar-Maia, A., Stybayeva, G., & Revzin, A. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-00201-6 · Cited by 99
Spheroid Engineering in Microfluidic Devices
Tevlek, A., Keçili, S., Ozcelik, O. S., Külah, H., & Tekin, H. C. (2023) · ACS Omega · doi:10.1021/acsomega.2c06052 · Cited by 104
Digital Microfluidics for Automated Hanging Drop Cell Spheroid Culture
Aijian, A. P., & Garrell, R. L. (2015) · SLAS Technology · doi:10.1177/2211068214562002 · Cited by 87
“A number of microfluidic techniques for spheroid culture have been developed that can enable high-throughput and massively parallel spheroid formation, but which do not support the interrogation of spheroids individually on the same device.(19-22) Rotary vessels and spinner flasks can also be used to generate a large…”
Applications of Light-Sheet Microscopy in Microdevices
Albert-Smet, I., Marcos-Vidal, A., Vaquero, J. J., Desco, M., Muñoz‐Barrutia, A., & Ripoll, J. (2019) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2019.00001 · Cited by 93
Rodenhizer, D., Dean, T., D'Arcangelo, E., & McGuigan, A. P. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701174 · Cited by 80
Chen, C., Rengarajan, V., Kjar, A., & Huang, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.10.003 · Cited by 77
A comprehensive review on scaffold-free bioinks for bioprinting
Khoshnood, N., & Zamanian, A. (2020) · Bioprinting · doi:10.1016/j.bprint.2020.e00088 · Cited by 76
Three-Dimensional Cell Culture and Drug Testing in a Microfluidic Sidewall-Attached Droplet Array
Zhao, S.-P., Ma, Y., Lou, Q., Zhu, H., Yang, B., & Fang, Q. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02267 · Cited by 72
Spheroids in cancer research: Recent advances and opportunities
Arora, S., Singh, S., Mittal, A. K., Desai, N., Khatri, D. K., Gugulothu, D. B., Lather, V., Pandita, D., & Vora, L. K. (2024) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2024.106033 · Cited by 92
Microfluidics-Based in Vivo Mimetic Systems for the Study of Cellular Biology
Kim, D., Wu, X., Young, A. T., & Haynes, C. L. (2014) · Accounts of Chemical Research · doi:10.1021/ar4002608 · Cited by 68
Olofsson, K., Carannante, V., Ohlin, M., Frisk, T., Kushiro, K., Takai, M., Lundqvist, A., Önfelt, B., & Wiklund, M. (2018) · Lab on a Chip · doi:10.1039/c8lc00537k · Cited by 67
Acoustic assembly of cell spheroids in disposable capillaries
Wu, Y., Ao, Z., Chen, B., Muhsen, M., Bondesson, M., Lu, X., & Guo, F. (2018) · Nanotechnology · doi:10.1088/1361-6528/aae4f1 · Cited by 67
Recent Advances in Microfluidic Platforms for Programming Cell‐Based Living Materials
Zhang, P., Shao, N., & Qin, L. (2021) · Advanced Materials · doi:10.1002/adma.202005944 · Cited by 63
Cavo, M., Cave, D. D., D’Amone, E., Gigli, G., Lonardo, E., & del Mercato, L. L. (2020) · Scientific Reports · doi:10.1038/s41598-020-66908-8 · Cited by 61
Heterotypic tumor spheroids: a platform for nanomedicine evaluation
Vakhshiteh, F., Bagheri, Z., Soleimani, M., Ahvaraki, A., Pournemat, P., Alavi, S. E., & Madjd, Z. (2023) · Journal of Nanobiotechnology · doi:10.1186/s12951-023-02021-y · Cited by 75
“PDMS is widely used due to its superior optical transparency, manufacture capability, high gas permeability, and biocompatibility, making it a common material for constructing microfluidic chips for cell culture [50].”
BackgroundEvaluation of cancer immunotherapy using mini-tumor chips
Ao, Z., Cai, H., Wu, Z., Hu, L., Li, X., Kaurich, C., Gu, M., Cheng, L., Lu, X., & Guo, F. (2022) · Theranostics · doi:10.7150/thno.71761 · Cited by 52
“The viable cells can then be subject to various treatments for drug response prediction treatment selection [14-19].”
BackgroundPhoto‐crosslinkable hydrogel‐based 3D microfluidic culture device
Lee, Y., Lee, J. M., Bae, P. K., Chung, I. Y., Chung, B. G., & Chung, B. G. (2015) · Electrophoresis · doi:10.1002/elps.201400465 · Cited by 55
Fabrication of Cell Spheroids for 3D Cell Culture and Biomedical Applications
Park, S. Y., Hong, H. J., & Lee, H. J. (2022) · BioChip Journal · doi:10.1007/s13206-022-00086-9 · Cited by 54
“Spheroid formation is controlled by the flow rate and the design of the microwells connected to the channels [57, 58].”
BackgroundMangani, S., Kremmydas, S., & Karamanos, N. K. (2025) · Cancers · doi:10.3390/cancers17071161 · Cited by 57
Khot, M. I., Levenstein, M. A., de Boer, G., Armstrong, G., Maisey, T. I., Svavarsdottir, H. S., Andrew, H., Perry, S., Kapur, N., & Jayne, D. G. (2020) · Scientific Reports · doi:10.1038/s41598-020-72952-1 · Cited by 48
Wu, G., Wu, J., Li, Z., Shi, S., Wu, D., Wang, X., Xu, H., Liu, H., Huang, Y., Wang, R., et al. (2022) · Bio-Design and Manufacturing · doi:10.1007/s42242-022-00188-1 · Cited by 42
Patra, B., Peng, Y.-S., Peng, C.-C., Liao, W.-H., Chen, Y.-A., Lin, K.-H., Tung, Y.-C., & Lee, C.-H. (2014) · Biomicrofluidics · doi:10.1063/1.4895568 · Cited by 41
Self-citationMicrofluidics platform for measurement of volume changes in immobilized intestinal enteroids
Jin, B.-J., Battula, S., Zachos, N., Kovbasnjuk, O., Fawlke-Abel, J., In, J., Donowitz, M., & Verkman, A. S. (2014) · Biomicrofluidics · doi:10.1063/1.4870400 · Cited by 39
Robotic Production of Cancer Cell Spheroids with an Aqueous Two-phase System for Drug Testing
Ham, S. L., Atefi, E., Fyffe, D., & Tavana, H. (2015) · Journal of Visualized Experiments · doi:10.3791/52754 · Cited by 36
Microfluidic device for primary tumor spheroid isolation
Zhou, J., Su, J. L.-S., Fu, X., Zheng, L., & Yin, Z. (2017) · Experimental Hematology and Oncology · doi:10.1186/s40164-017-0084-3 · Cited by 45
Zhang, Z., Rahmat, J. N., Mahendran, R., & Zhang, Y. (2020) · Advanced Science · doi:10.1002/advs.202001831 · Cited by 39
Stem Cell Spheroids and Ex Vivo Niche Modeling: Rationalization and Scaling-Up
Chimenti, I., Massai, D., Morbiducci, U., Beltrami, A. P., Pesce, M., & Messina, E. (2017) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-017-9741-5 · Cited by 37
Advances in numerical approaches for microfluidic cell analysis platforms
Sheidaei, Z., Akbarzadeh, P., & Kashaninejad, N. (2020) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2020.07.008 · Cited by 45
Time-resolved non-invasive metabolomic monitoring of a single cancer spheroid by microfluidic NMR
Patra, B., Sharma, M., Hale, W. G., & Utz, M. (2021) · Scientific Reports · doi:10.1038/s41598-020-79693-1 · Cited by 34
Self-citationOrganoid-based tissue engineering for advanced tissue repair and reconstruction
Hsiung, N., Ju, Y., Yang, K. C., Pu, Y., Zeng, W., Zhao, H., Zou, P., Ye, J., Yi, K., & Wang, X. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102093 · Cited by 56
“These systems incorporate responsive sensors for real-time parameter monitoring [218,219] and enable precise control of spheroid size and morphology through flow rate regulation [220].”
Patra, B., Lafontaine, J., Bavoux, M., Zerouali, K., Glory, A., Ahanj, M., Carrier, J., Gervais, T., & Wong, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-38666-9 · Cited by 34
Self-citationRecent Development of Microfluidic Technology for Cell Trapping in Single Cell Analysis: A Review
Deng, Y., Guo, Y., & Xu, B. (2020) · Processes · doi:10.3390/pr8101253 · Cited by 32
“Many new illumination, staining, and detection methods, such as flow cytometry [11], have been developed in order to increase the optical resolution of the microscope to observe the behavior of single cell [12].”
Imaging live cells at high spatiotemporal resolution for lab-on-a-chip applications
Chin, L. K., Lee, C., & Chen, B. (2016) · Lab on a Chip · doi:10.1039/c5lc01556a · Cited by 31
Self-citationJager, L. D., Canda, C.-M. A., Hall, C. A., Heilingoetter, C. L., Huynh, J., Kwok, S. S., Kwon, J. H., Richie, J. R., & Jensen, M. B. (2015) · Advances in Medical Sciences · doi:10.1016/j.advms.2015.09.005 · Cited by 30
“We did not include mechanical methods of dissociation involving filters, choppers, and/or microfluidic devices that may not be readily available to most laboratories [4,5,8].”
MethodKim, E. M., Lee, Y. B., Byun, H., Chang, H.-K., Park, J., & Shin, H. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b18048 · Cited by 31
Jackson, E., McDevitt, T. C., & Lu, H. (2017) · Lab on a Chip · doi:10.1039/c7lc00763a · Cited by 28
Rapid spheroid clearing on a microfluidic chip
Santisteban, T. S., Rabajania, O., Kalinina, I. M., Robinson, S. P., & Meier, M. (2017) · Lab on a Chip · doi:10.1039/c7lc01114h · Cited by 35
Sakai, Y., Hattori, K., Yanagawa, F., Sugiura, S., Kanamori, T., & Nakazawa, K. (2014) · Biotechnology Journal · doi:10.1002/biot.201300559 · Cited by 25
Microfluidic technologies to engineer mesenchymal stem cell aggregates—applications and benefits
Salehi, S. S., Shamloo, A., & Hannani, S. K. (2020) · Biophysical Reviews · doi:10.1007/s12551-020-00613-8 · Cited by 24
Fly-on-a-Chip: Microfluidics for Drosophila melanogaster Studies
Zabihihesari, A., Hilliker, A. J., & Rezai, P. (2019) · Integrative Biology · doi:10.1093/intbio/zyz037 · Cited by 23
Zuchowska, A., Marciniak, K., Bazylinska, U., Jastrzebska, E., Wilk, K. A., & Brzozka, Z. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.08.037 · Cited by 22
Lopa, S., Piraino, F., Kemp, R. J., Di, C., Lovati, A. B., Giancamillo, A. D., Moroni, L., Peretti, G. M., Rasponi, M., & Moretti, M. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25557 · Cited by 28
“Cell spheroids have been generated combining the actions of fluid flow and gravity force in microfluidic devices (Fu et al. 2014; Patra et al. 2013; Piraino et al. 2012a) or exploiting gravityenforced cell assembly in manual (Cavnar et al.”
MethodMicrofabrication methods for 3D spheroids formation and their application in biomedical engineering
Ahn, S., Kim, D., Cho, K., & Koh, W. (2023) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-022-1327-5 · Cited by 22
Lopa, S., Piraino, F., Talò, G., Mainardi, V. L., Bersini, S., Pierro, M., Zagra, L., Rasponi, M., & Moretti, M. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00366 · Cited by 19
Red emissive N–S co-doped carbon dots for live imaging of tumor spheroid in the microfluidic device
Ermis, E., Bagheri, Z., Behroodi, E., Latifi, H., Rahimifard, M., & Ajorlou, E. (2021) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2021.11.006 · Cited by 22
Seo, J., Ha, G., Lee, G., Nasiri, R., & Lee, J. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.10.036 · Cited by 20
Bavoux, M., Kamio, Y., Vigneux-Foley, E., Lafontaine, J., Najyb, O., Refet-Mollof, E., Carrier, J., Gervais, T., & Wong, P. (2021) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2021.01.018 · Cited by 20
Kim, H., Cho, C. H., & Park, J. (2018) · Biomicrofluidics · doi:10.1063/1.5039965 · Cited by 16
Acoustofluidic cell micro-dispenser for single cell trajectory control
Richard, C., Devendran, C., Ashtiani, D., Cadarso, V. J., & Neild, A. (2022) · Lab on a Chip · doi:10.1039/d2lc00216g · Cited by 16
In Pursuit of Designing Multicellular Engineered Living Systems: A Fluid Mechanical Perspective
Serrano, J. C., Gupta, S. K., Kamm, R. D., & Guo, M. (2020) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-072220-013845 · Cited by 15
Inventions and Innovations in Preclinical Platforms for Cancer Research
Moshksayan, K., Kashaninejad, N., & Saidi, M. S. (2018) · Inventions · doi:10.3390/inventions3030043 · Cited by 13
“[88] 2013 murine ES cell, HepG2, African green monkey kidney epithelial fibroblast (COS-7) Channel: 150, 1400, 25,000 Well: 200 × 200, 250 24 h for COS-7, 1 day for HepG2, 16 h for ES COS-7 and HepG2 spheroids are 80 and 200 μm HepG2 and COS-7 cell 107 and 105 respectively 1 μL/min for cell seeding and 20 μL/min for c…”
Ieong, K. A., Yang, C., Wong, C., Shui, A., Wu, T. Y.-H., Chen, T., & Lam, R. H. W. (2017) · Micromachines · doi:10.3390/mi8060167 · Cited by 13
“[28] reported an important microfluidic technique to form multiple spheroids with a uniform size, which greatly improved consistence of the spheroid properties for more promising results.”
BackgroundA Review on the Recent Advancement in “Tumour Spheroids-on-a-Chip”
Khot, M. I., Levenstein, M. A., Kapur, N., & Jayne, D. G. (2019) · Journal of Cancer Research and Practice · doi:10.4103/jcrp.jcrp_23_18 · Cited by 13
“Noncell adherent [14-22] Simple and convenient microfluidic setup for spheroid culture”
BackgroundMethodA Review on Nano/Microfluidic Devices for Cell Isolation Techniques: Recent Progress and Advances
Garshasbi, H. R., & Naghib, S. M. (2023) · Current Nanoscience · doi:10.2174/0115734137264742231001142853 · Cited by 11
Zhu, H., Roode, L. W. Y., Parry, A., Erkamp, N. A., Rodriguez‐Garcia, M., Narita, M., Shen, Y., Ou, Y., Toprakcioglu, Z., Narita, M., et al. (2022) · Advanced NanoBiomed Research · doi:10.1002/anbr.202200138 · Cited by 10
Boussommier-Calleja, A. (2020) · Bioengineering Innovative Solutions for Cancer · doi:10.1016/b978-0-12-813886-1.00013-9 · Cited by 10
Lee, Y. N., Yi, H. J., Goh, H., Park, J. Y., Ferber, S., Shim, I. K., & Kim, S. C. (2020) · Cells · doi:10.3390/cells9122551 · Cited by 11
“Recently, several studies have shown the production of cancer cell spheroids using microchips and have demonstrated their use in drug screening [18–20] and islet / DIPC reaggregation [21,22].”
Lineage Specific Differentiation of Magnetic Nanoparticle-Based Size Controlled Human Embryoid Body
Son, B., Kim, J. A., Cho, S., Jeong, G., Kim, B., Hwang, N. S.-Y., & Park, T. H. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00141 · Cited by 10
Markoski, A., Wong, I. Y., & Borenstein, J. T. (2021) · Frontiers in Medical Technology · doi:10.3389/fmedt.2021.646441 · Cited by 9
“The manufacturing time and scalability of the device presented here surpasses that of existing platforms (20, 21).”
BackgroundResultSharma, M., Goudar, V. S., Koduri, M. P., Tseng, F., & Bhattacharya, M. (2021) · Applied Sciences · doi:10.3390/app11104636 · Cited by 9
Siao, Y.-J., Peng, C., Tung, Y., & Chen, Y. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.869184 · Cited by 7
Self-citationFlip channel: A microfluidic device for uniform-sized embryoid body formation and differentiation
Chen, Y., Peng, C., & Tung, Y. (2015) · Biomicrofluidics · doi:10.1063/1.4931638 · Cited by 8
Self-citationEffect of a dual inlet channel on cell loading in microfluidics
Yun, H., Kim, K.-S., & Lee, W. G. (2014) · Biomicrofluidics · doi:10.1063/1.4901929 · Cited by 7
Three-dimensional spheroid models for cardiovascular biology and pathology
Krug, A., Inserra, G., Drewes, R., Krajnik, A., Brazzo, J. A., Mousso, T., Heo, S., & Bae, Y. (2025) · Mechanobiology in Medicine · doi:10.1016/j.mbm.2025.100144 · Cited by 11
Kannan, S., Peng, C., Wu, H., & Tung, Y. (2024) · Biosensors · doi:10.3390/bios14020096 · Cited by 8
“Before the experiments, the microfluidic channel walls are coated with 5 wt% surfactant (Synperonic F108, Sigma Aldrich 07579, Merck KGaA, Darmstadt, Germany) overnight to prevent cell attachment on the surfaces (STEP 1) [19].”
BackgroundMethodSelf-citationMicrofluidic measurement of individual cell membrane water permeability
Huang, L., Benson, J. D., & Almasri, M. F. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338441 · Cited by 6
Kannan, S., Ko, P., Wu, H., & Tung, Y. (2023) · Biomicrofluidics · doi:10.1063/5.0161752 · Cited by 5
Self-citationEngineering in vitro complex pathophysiologies for drug discovery purposes
Gaspar, D., & Zeugolis, D. I. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.08.007 · Cited by 5
Shim, I. K., Lee, S. J., Lee, Y. N., Kim, D., Goh, H., Youn, J., Jang, J., Kim, D. S., & Kim, D. S. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14020400 · Cited by 5
“Many research groups have reported on technologies and applications related to the differentiation of insulin-producing cells using stem cells [11,28,29].”
BackgroundSatoh, T., Sugiura, S., Sumaru, K., Ozaki, S., Gomi, S., Kurakazu, T., Oshima, Y., & Kanamori, T. (2014) · Biomicrofluidics · doi:10.1063/1.4871036 · Cited by 5
St‐Georges‐Robillard, A., Masse, M., Kendall‐Dupont, J., Strupler, M., Patra, B., Jermyn, M., Mes‐Masson, A., Leblond, F., & Gervais, T. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2211159 · Cited by 4
“The microfluidic chip in which spheroids were formed and maintained alive is based on a design by Patra et al.7.”
MethodSelf-citationMACS-W: A modified optical clearing agent for imaging 3D cell cultures
Zhong, X., Gao, C., Li, H., He, Y., Fei, P., Chen, Z., Gu, Z., Zhu, D. Y., & Yu, T. (2023) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545823500189 · Cited by 6
Combinatorial Approach in Rationale Design of Polymeric Nanomedicines for Cancer
Singh, A., & Amiji, M. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-50878-0.00013-6 · Cited by 7
Gualque, M. W. D. L., Vaso, C. O., dos Santos, K. S., Galeane, M. C., Gomes, P. C., Palma, M. S., Mendes‐Giannini, M. J. S., Moroz, A., & Fusco‐Almeida, A. M. (2024) · Future Microbiology · doi:10.1080/17460913.2024.2421632 · Cited by 3
Evaluation of allylated gelatin as a bioink supporting spontaneous spheroid formation of HepG2 cells
Kripamol, R., Velayudhan, S., & Kumar, P. R. A. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.133259 · Cited by 3
Integrating Micro Process Chemistry into an NMR Spectrometer
Schulte-Hermann, J., Yang, J., Rivera, A. C. H., Korvink, J. G., MacKinnon, N., & Brandner, J. J. (2023) · Chemie Ingenieur Technik · doi:10.1002/cite.202300103 · Cited by 2
Dezauzier, R., Fomina, A., & Dittrich, P. S. (2025) · Lab on a Chip · doi:10.1039/d5lc00210a · Cited by 2
Reconfigurable microfluidic device with discretized sidewall
Oono, M., Yamaguchi, K., Rasyid, A., Takano, A., Tanaka, M., & Futai, N. (2017) · Biomicrofluidics · doi:10.1063/1.4983148 · Cited by 1
Eş, İ., Ionescu, A. T., Görmüş, B. M., İnci, F., Marques, M. P. C., Szita, N., & de la Torre, L. G. (2024) · Biotechnology Progress · doi:10.1002/btpr.3470 · Cited by 4
Microfluidics: A New Tool for Modeling Cancer-Immune
Boussommier-Calleja, I., Li, R., Chen, M. B., & Kamm, R. D. (2016) · Cited by 2
Emerging Hydrophobized Surfaces for Rapid Fabrication of 3D Tumor Models
Monteiro, M. V., Carvalho, M. T., Moura, B. S., Gaspar, V. M., & Mano, J. F. (2025) · ACS Materials Letters · doi:10.1021/acsmaterialslett.4c02280 · Cited by 1
Cadena, M. F., Cóndor, M., Raith, D., Sapre, A., Follo, M., Layedra, G., Mertelsmann, R. H., Pérez, M., & Lerner, B. (2025) · Biosensors · doi:10.3390/bios15100693 · Cited by 1
“To address this, many existing systems focus on short-term analysis, relying on strategies such as physical clamping that may induce mechanical stress [16] or have different goals, such as spheroid formation [17].”
In vitro 3D Spheroid Culture Developed on the Parafilm Surface Using HEK-293 Cells
Eroğlu, E. (2020) · Academic Perspective Procedia · doi:10.33793/acperpro.03.01.48 · Cited by 1
Robotic System for Organoid Assembly in a Multi-Well Microfluidic ChipPreprint
Sachs, D. M., & Costa, K. D. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.10.02.560601 · Cited by 1
Metadata
- Authors
- Patra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C.
- Affiliations
- National Yang Ming University (TW)
- Research Center for Applied Sciences, Academia Sinica 3 , Taipei 11529, Taiwan
- Research Center for Applied Science, Academia Sinica (TW)
- National Taiwan University (TW)
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2013-09-01
- Volume
- 7
- Issue
- 5
- Pages
- 54114-54114
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC3808411
- OpenAlex
- W1988781086
- Cited by
- 109
- References
- 38
- Citations by year
- 2025: 6 · 2024: 6 · 2023: 8 · 2022: 7 · 2021: 11 · 2020: 16 · 2019: 6 · 2018: 13 · 2017: 13 · 2016: 6 · 2015: 8 · 2014: 7 · 2013: 1
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Biomicrofluidics (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council (101-2628-E-001-002-MY3)
- Academia Sinica
- National Health Research Institutes
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- cell spheroids, microfluidics, 3D cell culture, spheroid formation, flow cytometry, embryonic stem cells, carcinoma cells, fibroblasts, cell-cell interactions, spatial confinement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.