The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Recreating blood-brain barrier physiology and structure on chip: A novel neurovascular microfluidic bioreactor
Open accessAbstract
The blood-brain barrier (BBB) is a critical structure that serves as the gatekeeper between the central nervous system and the rest of the body. It is the responsibility of the BBB to facilitate the entry of required nutrients into the brain and to exclude potentially harmful compounds; however, this complex structure has remained difficult to model faithfully in vitro. Accurate in vitro models are necessary for understanding how the BBB forms and functions, as well as for evaluating drug and toxin penetration across the barrier. Many previous models have failed to support all the cell types involved in the BBB formation and/or lacked the flow-created shear forces needed for mature tight junction formation. To address these issues and to help establish a more faithful in vitro model of the BBB, we have designed and fabricated a microfluidic device that is comprised of both a vascular chamber and a brain chamber separated by a porous membrane. This design allows for cell-to-cell communication between endothelial cells, astrocytes, and pericytes and independent perfusion of both compartments separated by the membrane. This NeuroVascular Unit (NVU) represents approximately one-millionth of the human brain, and hence, has sufficient cell mass to support a breadth of analytical measurements. The NVU has been validated with both fluorescein isothiocyanate (FITC)-dextran diffusion and transendothelial electrical resistance. The NVU has enabled in vitro modeling of the BBB using all human cell types and sampling effluent from both sides of the barrier.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Highly efficient neural conversion of human ES and iPS cells by dual inhibition of SMAD signaling
Chambers, S. M., Fasano, C. A., Papapetrou, E. P., Tomishima, M., Sadelain, M., & Studer, L. (2009) · Nature Biotechnology · doi:10.1038/nbt.1529 · Cited by 3,620
A ROCK inhibitor permits survival of dissociated human embryonic stem cells
Watanabe, K., Ueno, M., Kamiya, D., Nishiyama, A., Matsumura, M., Wataya, T., Takahashi, J. B., Nishikawa, S., Nishikawa, S.-I., Muguruma, K., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1310 · Cited by 2,055
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Shi, Y., Kirwan, P., & Livesey, F. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.116 · Cited by 972
Human cerebral cortex development from pluripotent stem cells to functional excitatory synapses
Shi, Y., Kirwan, P., Smith, J., Robinson, H. P. C., & Livesey, F. J. (2012) · Nature Neuroscience · doi:10.1038/nn.3041 · Cited by 813
A new blood–brain barrier model using primary rat brain endothelial cells, pericytes and astrocytes
Nakagawa, S., Deli, M. A., Kawaguchi, H., Shimizudani, T., Shimono, T., Kittel, Á., Tanaka, K., & Niwa, M. (2009) · Neurochemistry International · doi:10.1016/j.neuint.2008.12.002 · Cited by 728
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
The role of shear stress in Blood-Brain Barrier endothelial physiology
Cucullo, L., Hossain, M., Puvenna, V., Marchi, N., & Janigro, D. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-40 · Cited by 438
Impedance-based cell monitoring: barrier properties and beyond
Benson, K., Cramer, S., & Galla, H.-J. (2013) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-10-5 · Cited by 400
Wojciak-Stothard, B., & Ridley, A. J. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200210135 · Cited by 344
SyM-BBB: a microfluidic blood brain barrier model
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Mills, I. R., Sidoryk-Wegrzynowicz, M., Aschner, M., & Pant, K. (2013) · Lab on a Chip · doi:10.1039/c2lc41208j · Cited by 339
Hatherell, K., Couraud, P.-O., Romero, I. A., Weksler, B., & Pilkington, G. J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.05.012 · Cited by 334
Gaillard, P. J., Voorwinden, L. H., Nielsen, J. L., Ivanov, A., Atsumi, R., Engman, H., Ringbom, C., de Boer, A. G., & Breimer, D. D. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(00)00123-8 · Cited by 331
Vitamin C crosses the blood-brain barrier in the oxidized form through the glucose transporters.
Agus, D. B., Gambhir, S. S., Pardridge, W. M., Spielholz, C., Baselga, J., Vera, J. C., & Golde, D. W. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119832 · Cited by 329
Protection and Recycling of α-Tocopherol in Human Erythrocytes by Intracellular Ascorbic Acid
May, J. M., Qu, Z.-C., & Mendiratta, S. (1998) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1997.0473 · Cited by 316
Self-citationOrgans-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
Self-citationBrown, R. C., Morris, A. P., & O'Neil, R. G. (2007) · Brain Research · doi:10.1016/j.brainres.2006.10.083 · Cited by 291
In Vitro Blood–Brain Barrier Models: Current and Perspective Technologies
Naik, P., & Cucullo, L. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23022 · Cited by 288
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
The relevance and potential roles of microphysiological systems in biology and medicine
Wikswo, J. P. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214542068 · Cited by 248
Self-citationCytokine Signaling Modulates Blood-Brain Barrier Function
Pan, W., P. Stone, K., Hsuchou, H., K. Manda, V., Zhang, Y., & J. Kastin, A. (2011) · Current Pharmaceutical Design · doi:10.2174/138161211798220918 · Cited by 241
Primary culture of capillary endothelium from rat brain
Bowman, P. D., Betz, A. L., aR, D., Wolinsky, J. S., Penney, J. B., Shivers, R. R., & Goldstein, G. W. (1981) · In Vitro · doi:10.1007/bf02618147 · Cited by 236
How to measure drug transport across the blood-brain barrier
Bickel, U. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.15 · Cited by 213
Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
Organs-on-a-Chip: A Focus on Compartmentalized Microdevices
Moraes, C., Mehta, G., Lesher-Perez, S. C., & Takayama, S. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0455-6 · Cited by 199
Ahmad, A. A., Taboada, C. B., Gassmann, M., & Ogunshola, O. O. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.148 · Cited by 182
Engineering Challenges for Instrumenting and Controlling Integrated Organ-on-Chip Systems
Wikswo, J. P., Block, F. E., Cliffel, D. E., Goodwin, C. R., Marasco, C. C., Markov, D. A., McLean, D. L., McLean, J. A., McKenzie, J. R., Reiserer, R. S., et al. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244891 · Cited by 176
Self-citationIrreversible, direct bonding of nanoporous polymer membranes to PDMS or glass microdevices
Aran, K., Sasso, L. A., Kamdar, N., & Zahn, J. D. (2010) · Lab on a Chip · doi:10.1039/b924816a · Cited by 159
Collagen-based brain microvasculature modelin vitrousing three-dimensional printed template
Kim, J., Kim, H. N., Im, S.-K., Chung, S. H., Kang, J. Y., & Choi, N. (2015) · Biomicrofluidics · doi:10.1063/1.4917508 · Cited by 155
Hoffmann, A., Bredno, J., Wendland, M. F., Derugin, N., Ohara, P. T., & Wintermark, M. (2010) · Translational Stroke Research · doi:10.1007/s12975-010-0049-x · Cited by 155
Tang, X., Zhou, L., Biel, A., Marchetto, M. C., Muotri, A. R., Gage, F. H., & Chen, G. (2013) · Stem Cell Research · doi:10.1016/j.scr.2013.05.002 · Cited by 147
Shimizu, F., Sano, Y., Saito, K., Abe, M., Maeda, T., Haruki, H., & Kanda, T. (2011) · Neurochemical Research · doi:10.1007/s11064-011-0626-8 · Cited by 144
Boissart, C., Poulet, A., Georges, P., Darville, H., Julita, E., Delorme, R., Bourgeron, T., Peschanski, M., & Benchoua, A. (2013) · Translational Psychiatry · doi:10.1038/tp.2013.71 · Cited by 140
McCue, S., Dajnowiec, D., Xu, F., Zhang, M., Jackson, M. R., & Langille, B. L. (2006) · Circulation Research · doi:10.1161/01.res.0000216595.15868.55 · Cited by 137
ROCK1 and 2 differentially regulate actomyosin organization to drive cell and synaptic polarity
Litwa, K., Badoual, M., Asmussen, H., Patel, H., Whitmore, L. A., & Horwitz, A. R. (2015) · The Journal of Cell Biology · doi:10.1083/jcb.201504046 · Cited by 135
Booth, R., & Kim, H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1086-5 · Cited by 125
Walsh, T. G., Murphy, R. P., Fitzpatrick, P., Rochfort, K. D., Guinan, A. F., Murphy, A. W., & Cummins, P. M. (2011) · Journal of Cellular Physiology · doi:10.1002/jcp.22655 · Cited by 118
Modelling the Neurovascular Unit and the Blood-Brain Barrier with the Unique Function of Pericytes
Vandenhaute, E., Dehouck, L., Boucau, M., Sevin, E., Uzbekov, R. E., Tardivel, M., Gosselet, F., Fénart, L., Cecchelli, R., & Dehouck, M. (2011) · Current Neurovascular Research · doi:10.2174/156720211798121016 · Cited by 117
Cucullo, L., Hossain, M., Tierney, W. S., & Janigro, D. (2013) · BMC Neuroscience · doi:10.1186/1471-2202-14-18 · Cited by 109
Stanimirovic, D. B., Bani‐Yaghoub, M., Perkins, M., & Haqqani, A. S. (2014) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2015.974545 · Cited by 88
Shawahna, R., Declèves, X., & Scherrmann, J. (2012) · Current Drug Metabolism · doi:10.2174/1389200211309010120 · Cited by 78
Tight junction disruption by cadmium in an in vitro human airway tissue model
Cao, X., Lin, H., Muskhelishvili, L., Latendresse, J. R., Richter, P., & Heflich, R. H. (2015) · Respiratory Research · doi:10.1186/s12931-015-0191-9 · Cited by 76
Kusch-Poddar, M., Drewe, J., Fux, I., & Gutmann, H. (2005) · Brain Research · doi:10.1016/j.brainres.2005.10.014 · Cited by 74
Easton, A. S., & Abbott, N. J. (2002) · Brain Research · doi:10.1016/s0006-8993(02)03281-x · Cited by 74
Takeshita, Y., Obermeier, B., Cotleur, A. C., Sano, Y., Kanda, T., & Ransohoff, R. M. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.05.013 · Cited by 74
Tidball, A. M., Bryan, M. R., Uhouse, M. A., Kumar, K. K., Aboud, A. A., Feist, J. E., Ess, K. C., Neely, M. D., Aschner, M., & Bowman, A. B. (2014) · Human Molecular Genetics · doi:10.1093/hmg/ddu609 · Cited by 70
Self-citationMolino, Y., Jabès, F., Lacassagne, E., Gaudin, N., & Khrestchatisky, M. (2014) · Journal of Visualized Experiments · doi:10.3791/51278 · Cited by 69
Sun, Z., Worden, M., Wroczynskyj, Y., Yathindranath, V., van Lierop, J., Hegmann, T., & Miller, D. W. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s62260 · Cited by 63
Drug delivery and in vitro models of the blood-brain barrier.
Cucullo, L., Aumayr, B., Rapp, E., & Janigro, D. (2005) · PubMed · Cited by 61
Shawahna, R., Declèves, X., & Scherrmann, J. (2012) · Current Drug Metabolism · doi:10.2174/138920013804545232 · Cited by 61
Roloff, F., Scheiblich, H., Dewitz, C., Dempewolf, S., Stern, M. K., & Bicker, G. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118536 · Cited by 58
Lamas, N. J., Johnson-Kerner, B., Roybon, L., Kim, Y. A., Garcia-Diaz, A., Wichterle, H., & Henderson, C. E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110324 · Cited by 52
PARK2 patient neuroprogenitors show increased mitochondrial sensitivity to copper
Aboud, A. A., Tidball, A. M., Kumar, K. K., Neely, M. D., Han, B., Ess, K. C., Hong, C. C., Erikson, K. M., Hedera, P., & Bowman, A. B. (2014) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.10.002 · Cited by 50
Self-citationFilipović, N., Ghimire, K., Saveljic, I. B., Milošević, Ž., & Rüegg, C. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1051973 · Cited by 45
Case study: adapting in vitro blood–brain barrier models for use in early-stage drug discovery
Vandenhaute, E., Sevin, E., Hallier-Vanuxeem, D., Dehouck, M., & Cecchelli, R. (2011) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.006 · Cited by 36
Transfer of ascorbic acid across the vascular endothelium: mechanism and self-regulation
May, J. M., Qu, Z., & Qiao, H. (2009) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00674.2008 · Cited by 36
Self-citationAscorbic acid prevents increased endothelial permeability caused by oxidized low density lipoprotein
May, J. M., & Qu, Z. (2010) · Free Radical Research · doi:10.3109/10715762.2010.508496 · Cited by 35
Self-citationNitric oxide-induced perturbations in a cell culture model of the blood-brain barrier
Hurst, R. D., & Fritz, I. B. (1996) · Journal of Cellular Physiology · Cited by 35
ASTROCYTE‐CONDITIONED MEDIUM INDUCES BLOOD‐BRAIN BARRIER PROPERTIES IN ENDOTHELIAL CELLS
Yamagata, K., Tagami, M., Nara, Y., Mitani, M., Kubota, A., Fujino, H., Numano, F., Kato§, T., & Yamori, Y. (1997) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1997.tb02117.x · Cited by 34
Zhang, Z., McGoron, A. J., Crumpler, E. T., & Li, C.-Z. (2010) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-010-9037-6 · Cited by 28
In Vitro Models to Study the Blood Brain Barrier
Vernon, H. J., Clark, K. A. A., & Bressler, J. P. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-170-3_10 · Cited by 24
Microfabricated scaffold-guided endothelial morphogenesis in three-dimensional culture
Liu, Y., Markov, D. A., Wikswo, J. P., & McCawley, L. J. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9554-2 · Cited by 19
Self-citationBiology coming full circle: Joining the whole and the parts
Wikswo, J. P., & Porter, A. P. (2015) · Experimental Biology and Medicine · doi:10.1177/1535370214564534 · Cited by 19
Self-citationGonzález‐Burgos, E., Carretero, M., & Gómez-Serranillos, M. P. (2013) · Planta Medica · doi:10.1055/s-0033-1350797 · Cited by 12
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
Induced pluripotent stem cells in disease modelling and drug discovery
Rowe, R. G., & Daley, G. Q. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0100-z · Cited by 670
Park, T.-E., Mustafaoglu, N., Herland, A., Hasselkus, R., Mannix, R., FitzGerald, E. A., Prantil-Baun, R., Watters, A., Henry, O., Benz, M., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10588-0 · Cited by 594
Metadata
- Authors
- Brown, J. A., Pensabene, V., Markov, D. A., Allwardt, V., Neely, M. D., Shi, M., Britt, C. M., Hoilett, O. S., Yang, Q., Brewer, B. M., Samson, P. C., McCawley, L. J., May, J. M., Webb, D. J., Li, D., Bowman, A. B., Reiserer, R. S., & Wikswo, J. P.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2015-09-01
- Volume
- 9
- Issue
- 5
- Pages
- 054124-054124
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W1847104216
- Cited by
- 410
- References
- 66
- FWCI
- 16.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.