The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability
Open accessAbstract
We describe a microfluidic genetic analysis system that represents a previously undescribed integrated microfluidic device capable of accepting whole blood as a crude biological sample with the endpoint generation of a genetic profile. Upon loading the sample, the glass microfluidic genetic analysis system device carries out on-chip DNA purification and PCR-based amplification, followed by separation and detection in a manner that allows for microliter samples to be screened for infectious pathogens with sample-in–answer-out results in <30 min. A single syringe pump delivers sample/reagents to the chip for nucleic acid purification from a biological sample. Elastomeric membrane valving isolates each distinct functional region of the device and, together with resistive flow, directs purified DNA and PCR reagents from the extraction domain into a 550-nl chamber for rapid target sequence PCR amplification. Repeated pressure-based injections of nanoliter aliquots of amplicon (along with the DNA sizing standard) allow electrophoretic separation and detection to provide DNA fragment size information. The presence of Bacillus anthracis (anthrax) in 750 nl of whole blood from living asymptomatic infected mice and of Bordetella pertussis in 1 μl of nasal aspirate from a patient suspected of having whooping cough are confirmed by the resultant genetic profile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Mattoo, S., & Cherry, J. D. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.2.326-382.2005 · Cited by 1,138
Purification and Characterization of PCR-Inhibitory Components in Blood Cells
Al-Soud, W. A., & Rådström, P. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.2.485-493.2001 · Cited by 944
Microfabrication Inside Capillaries Using Multiphase Laminar Flow Patterning
Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Science · doi:10.1126/science.285.5424.83 · Cited by 659
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
PicoGreen quantitation of DNA: effective evaluation of samples pre- or post-PCR
Ahn, S. (1996) · Nucleic Acids Research · doi:10.1093/nar/24.13.2623 · Cited by 474
Single-Molecule DNA Amplification and Analysis in an Integrated Microfluidic Device
Lagally, E. T., Medintz, I. L., & Mathies, R. A. (2001) · Analytical Chemistry · doi:10.1021/ac001026b · Cited by 430
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Point-of-care nucleic acid testing for infectious diseases
Niemz, A., Ferguson, T. M., & Boyle, D. S. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.01.007 · Cited by 838
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Innovations in optical microfluidic technologies for point-of-care diagnostics
Myers, F. B., & Lee, L. P. (2008) · Lab on a Chip · doi:10.1039/b812343h · Cited by 474
Zhang, C., & Xing, D. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm389 · Cited by 417
Microfluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
Protein immobilization techniques for microfluidic assays
Kim, D., & Herr, A. E. (2013) · Biomicrofluidics · doi:10.1063/1.4816934 · Cited by 376
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Cell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Scaling up: A guide to high‐throughput genomic approaches for biodiversity analysis
Porter, T. M., & Hajibabaei, M. (2018) · Molecular Ecology · doi:10.1111/mec.14478 · Cited by 305
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Microfluidic sample preparation: cell lysis and nucleic acid purification
Kim, J., Johnson, M., Hill, P., & Gale, B. K. (2009) · Integrative Biology · doi:10.1039/b905844c · Cited by 282
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J. (2008) · Lab on a Chip · doi:10.1039/b811314a · Cited by 259
Gong, J., & Kim, C.-J. “. (2008) · Lab on a Chip · doi:10.1039/b717417a · Cited by 258
Metadata
- Authors
- Easley, C. J., Karlinsey, J. M., Bienvenue, J. M., Legendre, L. A., Roper, M. G., Feldman, S. H., Hughes, M. A., Hewlett, E. L., Merkel, T. J., Ferrance, J. P., & Landers, J. P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-12-19
- Volume
- 103
- Issue
- 51
- Pages
- 19272-19277
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2063250806
- Cited by
- 547
- References
- 21
- FWCI
- 29.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.