MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST)
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Detection of glycogen in vivo would have utility in the study of normal physiology and many disorders. Presently, the only magnetic resonance (MR) method available to study glycogen metabolism in vivo is 13 C MR spectroscopy, but this technology is not routinely available on standard clinical scanners. Here, we show that glycogen can be detected indirectly through the water signal by using selective radio frequency (RF) saturation of the hydroxyl protons in the 0.5- to 1.5-ppm frequency range downfield from water. The resulting saturated spins are rapidly transferred to water protons via chemical exchange, leading to partial saturation of the water signal, a process now known as chemical exchange saturation transfer. This effect is demonstrated in glycogen phantoms at magnetic field strengths of 4.7 and 9.4 T, showing improved detection at higher field in adherence with MR exchange theory. Difference images obtained during RF irradiation at 1.0 ppm upfield and downfield of the water signal showed that glycogen metabolism could be followed in isolated, perfused mouse livers at 4.7 T before and after administration of glucagon. Glycogen breakdown was confirmed by measuring effluent glucose and, in separate experiments, by 13 C NMR spectroscopy. This approach opens the way to image the distribution of tissue glycogen in vivo and to monitor its metabolism rapidly and noninvasively with MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1966) · Food and Cosmetics Toxicology · doi:10.1016/s0015-6264(66)80573-4 · Cited by 4,287
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
Self-citationMagnusson, I., Rothman, D. L., Katz, L. D., Shulman, R. G., & Shulman, G. I. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115997 · Cited by 757
Cline, G. W., Petersen, K. F., Krssak, M., Shen, J., Hundal, R. S., Trajanoski, Z., Inzucchi, S., Dresner, A., Rothman, D. L., & Shulman, G. I. (1999) · New England Journal of Medicine · doi:10.1056/nejm199907223410404 · Cited by 675
Amide proton transfer (APT) contrast for imaging of brain tumors
Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10651 · Cited by 660
Self-citationChemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Aime, S., Barge, A., Castelli, D. D., Fedeli, F., Mortillaro, A., Nielsen, F. U., & Terreno, E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10106 · Cited by 381
Woessner, D. E., Zhang, S., Merritt, M. E., & Sherry, A. D. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20408 · Cited by 375
Self-citationProton exchange rates from amino acid side chains— implications for image contrast
Liepinsh, E., & Otting, G. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350106 · Cited by 333
McMahon, M. T., Gilad, A. A., Zhou, J., Sun, P. Z., Bulte, J. W. M., & van Zijl, P. C. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20818 · Cited by 330
Self-citation
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Self-citationKim, M., Gillen, J., Landman, B. A., Zhou, J., & van Zijl, P. C. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21873 · Cited by 691
Self-citationMagnetic resonance imaging of glutamate
Cai, K., Haris, M., Singh, A., Kogan, F., Greenberg, J. H., Hariharan, H., Detre, J. A., & Reddy, R. (2012) · Nature Medicine · doi:10.1038/nm.2615 · Cited by 660
Ling, W., Regatte, R. R., Navon, G., & Jerschow, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707666105 · Cited by 533
Alternatives to Gadolinium-Based Metal Chelates for Magnetic Resonance Imaging
Viswanathan, S., Kovacs, Z., Green, K. N., Ratnakar, S. J., & Sherry, A. D. (2010) · Chemical Reviews · doi:10.1021/cr900284a · Cited by 439
Self-citationChemical Exchange Saturation Transfer Contrast Agents for Magnetic Resonance Imaging
Sherry, A. D., & Woods, M. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151929 · Cited by 356
Self-citationvan Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationPractical data acquisition method for human brain tumor amide proton transfer (APT) imaging
Zhou, J., Blakeley, J. O., Hua, J., Kim, M., Laterra, J., Pomper, M. G., & van Zijl, P. C. M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21712 · Cited by 338
Self-citationNatural D ‐glucose as a biodegradable MRI contrast agent for detecting cancer
Chan, K. W. Y., McMahon, M. T., Kato, Y., Liu, G., Bulte, J. W. M., Bhujwalla, Z. M., Artemov, D., & van Zijl, P. C. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24520 · Cited by 337
Nuts and bolts of chemical exchange saturation transfer MRI
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2899 · Cited by 318
In vivo mapping of brain myo-inositol
Haris, M., Cai, K., Singh, A., Hariharan, H., & Reddy, R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.017 · Cited by 253
Imaging brain deoxyglucose uptake and metabolism by glucoCEST MRI
Nasrallah, F. A., Pagès, G., Kuchel, P. W., Golay, X., & Chuang, K.-H. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.79 · Cited by 179
Metadata
- Authors
- van Zijl, P. C. M., Jones, C. K., Ren, J., Malloy, C. R., & Sherry, A. D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-03-13
- Volume
- 104
- Issue
- 11
- Pages
- 4359-4364
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2054190705
- Cited by
- 420
- References
- 33
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.