The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Monitoring of lipid storage in Caenorhabditis elegans using coherent anti-Stokes Raman scattering (CARS) microscopy
Open accessAbstract
Better understanding of the fundamental mechanisms behind metabolic diseases requires methods to monitor lipid stores on single-cell level in vivo . We have used Caenorhabditis elegans as a model organism to demonstrate the limitations of fluorescence microscopy for imaging of lipids compared with coherent anti-Stokes Raman scattering (CARS) microscopy, the latter allowing chemically specific and label-free imaging in living organisms. CARS microscopy was used to quantitatively monitor the impact of genetic variations in metabolic pathways on lipid storage in 60 specimens of C. elegans . We found that the feeding-defective mutant pha-3 contained a lipid volume fraction one-third of that found in control worms. In contrast, mutants ( daf-2 , daf-4 dauer) with deficiencies in the insulin and transforming growth factors (IGF and TGF-β) signaling pathways had lipid volume fractions that were 1.4 and 2 times larger than controls, respectively. This was observed as an accumulation of small-sized lipid droplets in the hypodermal cells, hosting as much as 40% of the total lipid volume in contrast to the 9% for the wild-type larvae. Spectral CARS microscopy measurements indicated that this is accompanied by a shift in the ordering of the lipids from gel to liquid phase. We conclude that the degree of hypodermal lipid storage and the lipid phase can be used as a marker of lipid metabolism shift. This study shows that CARS microscopy has the potential to become a sensitive and important tool for studies of lipid storage mechanisms, improving our understanding of phenomena underlying metabolic disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nonlinear Optics
Shen, Y. R. (1984) · Cited by 5,211
The Nematode Caenorhabditis elegans
Wood, W. B. (1988) · Cold Spring Harbor Laboratory eBooks · Cited by 3,036
Nile red: a selective fluorescent stain for intracellular lipid droplets.
Greenspan, P., Mayer, E. P., & Fowler, S. D. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.3.965 · Cited by 2,543
Obesity and the regulation of energy balance
Spiegelman, B. M., & Flier, J. S. (2001) · Cell · doi:10.1016/s0092-8674(01)00240-9 · Cited by 2,398
Kimura, K. D., Tissenbaum, H. A., Liu, Y., & Ruvkun, G. (1997) · Science · doi:10.1126/science.277.5328.942 · Cited by 2,245
Molecular Regulation of Adipogenesis
Rosen, E. D., & Spiegelman, B. M. (2000) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.16.1.145 · Cited by 1,285
Autophagy Genes Are Essential for Dauer Development and Life-Span Extension in C. elegans
Meléndez, A., Tallóczy, Z., Seaman, M., Eskelinen, E.-L., Hall, D. H., & Levine, B. (2003) · Science · doi:10.1126/science.1087782 · Cited by 1,270
Lipid droplets: a unified view of a dynamic organelle
Martin, S., & Parton, R. G. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1912 · Cited by 1,169
Riddle, D. L., Blumenthal, T., Meyer, B. J., & Priess, J. R. (1998) · Cited by 1,047
Genome-wide RNAi analysis of Caenorhabditis elegans fat regulatory genes
Ashrafi, K., Chang, F. Y., Watts, J. L., Fraser, A. G., Kamath, R. S., Ahringer, J., & Ruvkun, G. (2003) · Nature · doi:10.1038/nature01279 · Cited by 980
Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Cheng, J.-X., & Xie, X. S. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp035693v · Cited by 963
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
The Surface of Lipid Droplets Is a Phospholipid Monolayer with a Unique Fatty Acid Composition
Tauchi-Sato, K., Ozeki, S., Houjou, T., Taguchi, R., & Fujimoto, T. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m207712200 · Cited by 753
Imaging lipid bodies in cells and tissues using third-harmonic generation microscopy
Débarre, D., Supatto, W., Pena, A.-M., Fabre, A., Tordjmann, T., Combettes, L., Schanne-Klein, M.-C., & Beaurepaire, E. (2006) · Nature Methods · doi:10.1038/nmeth813 · Cited by 578
The Principles of Nonlinear Optics
Knight, P. L. (1985) · Optica Acta: International Journal of Optics · doi:10.1080/713821646 · Cited by 568
TOR signalling in bugs, brain and brawn
Jacinto, E., & Hall, M. N. (2003) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1018 · Cited by 565
The genetics of feeding in Caenorhabditis elegans.
Avery, L. (1993) · Genetics · doi:10.1093/genetics/133.4.897 · Cited by 500
Estevez, M., Attisano, L., Wrana, J. L., Albert, P. S., Massagué, J., & Riddle, D. L. (1993) · Nature · doi:10.1038/365644a0 · Cited by 369
Intracellular lipid particles of eukaryotic cells
Zweytick, D., Athenstaedt, K., & Daum, G. (2000) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/s0005-2736(00)00294-7 · Cited by 333
Coherent Anti-Stokes Raman Scattering Imaging of Axonal Myelin in Live Spinal Tissues
Wang, H., Fu, Y., Zickmund, P., Shi, R., & Cheng, J.-X. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061911 · Cited by 316
Nan, X., Cheng, J.-X., & Xie, X. S. (2003) · Journal of Lipid Research · doi:10.1194/jlr.d300022-jlr200 · Cited by 311
A Caenorhabditis elegans nutrient response system partially dependent on nuclear receptor NHR-49
Van Gilst, M. R., Hadjivassiliou, H., & Yamamoto, K. R. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0506234102 · Cited by 285
Long, X., Spycher, C., Han, Z. S., Rose, A. M., Müller, F., & Avruch, J. (2002) · Current Biology · doi:10.1016/s0960-9822(02)01091-6 · Cited by 279
Eesley, G. L. (1979) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/0022-4073(79)90045-1 · Cited by 248
Fluorescent lipid probes: some properties and applications (a review)
Maier, O., Oberle, V., & Hoekstra, D. (2002) · Chemistry and Physics of Lipids · doi:10.1016/s0009-3084(02)00017-8 · Cited by 192
Developmental regulation of energy metabolism in Caenorhabditis elegans
Wadsworth, W. G., & Riddle, D. L. (1989) · Developmental Biology · doi:10.1016/0012-1606(89)90214-5 · Cited by 161
Kaiser, R. D., & London, E. (1998) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(98)00127-8 · Cited by 128
Characterization of Molecular Scale Environments in Polymer Films by Single Molecule Spectroscopy
Hou, Y., Bardo, A. M., Martinez, C., & Higgins, D. A. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp992312y · Cited by 123
Direct Measurement of Chain Order in Single Phospholipid Mono- and Bilayers with Multiplex CARS
Wurpel, G. W. H., Schins, J. M., & Müller, M. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp037629j · Cited by 90
Computation and visualization of three-dimensional soft tissue motion in the orbit
Abràmoff, M. D., & Viergever, M. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1000254 · Cited by 82
Dual-pump coherent anti-Stokes-Raman scattering microscopy
Burkacky, O., Zumbusch, A., Brackmann, C., & Enejder, A. M. K. (2006) · Optics Letters · doi:10.1364/ol.31.003656 · Cited by 79
Self-citationTargets of TGFβ-related signaling in Caenorhabditis elegans
Savage‐Dunn, C. (2001) · Cytokine & Growth Factor Reviews · doi:10.1016/s1359-6101(01)00015-6 · Cited by 32
Cited by
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Yue, S., Li, J., Lee, S.-Y., Lee, H. J., Shao, T., Song, B., Cheng, L., Masterson, T. A., Liu, X., Ratliff, T. L., et al. (2014) · Cell Metabolism · doi:10.1016/j.cmet.2014.01.019 · Cited by 929
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Video-Rate Molecular Imaging in Vivo with Stimulated Raman Scattering
Saar, B. G., Freudiger, C. W., Reichman, J., Stanley, C. M., Holtom, G. R., & Xie, X. S. (2010) · Science · doi:10.1126/science.1197236 · Cited by 844
Raman Techniques: Fundamentals and Frontiers
Jones, R. R., Hooper, D. C., Zhang, L., Wolverson, D., & Valev, V. K. (2019) · Nanoscale Research Letters · doi:10.1186/s11671-019-3039-2 · Cited by 804
Metadata
- Authors
- Hellerer, T., Axäng, C., Brackmann, C., Hillertz, P., Pilon, M., & Enejder, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-09-11
- Volume
- 104
- Issue
- 37
- Pages
- 14658-14663
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1967763112
- Cited by
- 314
- References
- 32
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.