Monitoring of lipid storage in Caenorhabditis elegans using coherent anti-Stokes Raman scattering (CARS) microscopy
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Better understanding of the fundamental mechanisms behind metabolic diseases requires methods to monitor lipid stores on single-cell level in vivo . We have used Caenorhabditis elegans as a model organism to demonstrate the limitations of fluorescence microscopy for imaging of lipids compared with coherent anti-Stokes Raman scattering (CARS) microscopy, the latter allowing chemically specific and label-free imaging in living organisms. CARS microscopy was used to quantitatively monitor the impact of genetic variations in metabolic pathways on lipid storage in 60 specimens of C. elegans . We found that the feeding-defective mutant pha-3 contained a lipid volume fraction one-third of that found in control worms. In contrast, mutants ( daf-2 , daf-4 dauer) with deficiencies in the insulin and transforming growth factors (IGF and TGF-β) signaling pathways had lipid volume fractions that were 1.4 and 2 times larger than controls, respectively. This was observed as an accumulation of small-sized lipid droplets in the hypodermal cells, hosting as much as 40% of the total lipid volume in contrast to the 9% for the wild-type larvae. Spectral CARS microscopy measurements indicated that this is accompanied by a shift in the ordering of the lipids from gel to liquid phase. We conclude that the degree of hypodermal lipid storage and the lipid phase can be used as a marker of lipid metabolism shift. This study shows that CARS microscopy has the potential to become a sensitive and important tool for studies of lipid storage mechanisms, improving our understanding of phenomena underlying metabolic disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nonlinear Optics
Shen, Y. R. (1984) · Cited by 5,211
The Nematode Caenorhabditis elegans
Wood, W. B. (1988) · Cold Spring Harbor Laboratory eBooks · Cited by 3,050
Nile red: a selective fluorescent stain for intracellular lipid droplets.
Greenspan, P., Mayer, E. P., & Fowler, S. D. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.3.965 · Cited by 2,543
Obesity and the regulation of energy balance
Spiegelman, B. M., & Flier, J. S. (2001) · Cell · doi:10.1016/s0092-8674(01)00240-9 · Cited by 2,398
Kimura, K. D., Tissenbaum, H. A., Liu, Y., & Ruvkun, G. (1997) · Science · doi:10.1126/science.277.5328.942 · Cited by 2,245
Molecular Regulation of Adipogenesis
Rosen, E. D., & Spiegelman, B. M. (2000) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.16.1.145 · Cited by 1,285
Autophagy Genes Are Essential for Dauer Development and Life-Span Extension in C. elegans
Meléndez, A., Tallóczy, Z., Seaman, M., Eskelinen, E.-L., Hall, D. H., & Levine, B. (2003) · Science · doi:10.1126/science.1087782 · Cited by 1,270
Lipid droplets: a unified view of a dynamic organelle
Martin, S., & Parton, R. G. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1912 · Cited by 1,169
Riddle, D. L., Blumenthal, T., Meyer, B. J., & Priess, J. R. (1997) · PubMed · Cited by 1,126
Genome-wide RNAi analysis of Caenorhabditis elegans fat regulatory genes
Ashrafi, K., Chang, F. Y., Watts, J. L., Fraser, A. G., Kamath, R. S., Ahringer, J., & Ruvkun, G. (2003) · Nature · doi:10.1038/nature01279 · Cited by 980
Cited by
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Yue, S., Li, J., Lee, S.-Y., Lee, H. J., Shao, T., Song, B., Cheng, L., Masterson, T. A., Liu, X., Ratliff, T. L., et al. (2014) · Cell Metabolism · doi:10.1016/j.cmet.2014.01.019 · Cited by 929
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Video-Rate Molecular Imaging in Vivo with Stimulated Raman Scattering
Saar, B. G., Freudiger, C. W., Reichman, J., Stanley, C. M., Holtom, G. R., & Xie, X. S. (2010) · Science · doi:10.1126/science.1197236 · Cited by 844
Raman Techniques: Fundamentals and Frontiers
Jones, R. R., Hooper, D. C., Zhang, L., Wolverson, D., & Valev, V. K. (2019) · Nanoscale Research Letters · doi:10.1186/s11671-019-3039-2 · Cited by 804
Insulin/insulin-like growth factor signaling in C. elegans
Murphy, C. T. (2013) · WormBook · doi:10.1895/wormbook.1.164.1 · Cited by 532
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Raman Spectroscopy for Chemical Biology Research
Dodo, K., Fujita, K., & Sodeoka, M. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c05359 · Cited by 329
Cell biology of lipid droplets
Thiele, C., & Spandl, J. (2008) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2008.05.009 · Cited by 305
Raman and CARS microspectroscopy of cells and tissues
Krafft, C., Dietzek, B., & Popp, J. (2009) · The Analyst · doi:10.1039/b822354h · Cited by 271
Lipid and Carbohydrate Metabolism in Caenorhabditis elegans
(2017) · Genetics · doi:10.1534/genetics.117.300106 · Cited by 263
Yen, K., Le, T. T., Bansal, A., Narasimhan, S. D., Cheng, J.-X., & Tissenbaum, H. A. (2010) · PLoS ONE · doi:10.1371/journal.pone.0012810 · Cited by 236
“elegans has been described with coherent anti-Stokes Raman scattering (CARS) microscopy [8,9].”
A living model for obesity and aging research:Caenorhabditis elegans
Shen, P., Yue, Y., & Park, Y. (2018) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2016.1220914 · Cited by 209
“Thus, fat accumulation is visualized without the need for labeling (Cheng and Xie, 2004; Hellerer et al., 2007).”
BackgroundMethodProteomic Study and Marker Protein Identification of Caenorhabditis elegans Lipid Droplets
Zhang, P., Na, H., Liu, Z., Zhang, S., Xue, P., Chen, Y., Pu, J., Peng, G., Huang, X., Yang, F., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.016345 · Cited by 193
Freudiger, C. W., Min, W., Holtom, G. R., Xu, B., Dantus, M., & Sunney Xie, X. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.294 · Cited by 188
“, to overcome the shortcomings of lipid staining techniques that often fail to stain all lipids uniforml”
Multimodal nonlinear optical microscopy
Yue, S., Slipchenko, M. N., & Cheng, J. ‐. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000027 · Cited by 180
Micro‐Raman spectroscopy of algae: Composition analysis and fluorescence background behavior
Huang, Y. Y., Beal, C. M., Cai, W. W., Ruoff, R. S., & Terentjev, E. M. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22617 · Cited by 145
Metadata
- Authors
- Hellerer, T., Axäng, C., Brackmann, C., Hillertz, P., Pilon, M., & Enejder, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-09-11
- Volume
- 104
- Issue
- 37
- Pages
- 14658-14663
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1967763112
- Cited by
- 314
- References
- 32
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.