Microfluidic system for on-chip high-throughput whole-animal sorting and screening at subcellular resolution
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We report a suite of key microfluidic devices for complex high-throughput whole-animal genetic and drug screens. We demonstrate a high-speed microfluidic sorter that can isolate and immobilize Caenorhabditis elegans in a well defined geometry for screening phenotypic features at subcellular resolution in physiologically active animals. We show an integrated chip containing individually addressable screening-chamber devices for incubation and exposure of individual animals to biochemical compounds and high-resolution time-lapse imaging of many animals on a single chip without the need for anesthesia. We describe a design for delivery of compound libraries in standard multiwell plates to microfluidic devices and also for rapid dispensing of screened animals into multiwell plates. When used in various combinations, these devices will facilitate a variety of high-throughput assays using whole animals, including mutagenesis and RNAi and drug screens at subcellular resolution, as well as high-throughput high-precision manipulations such as femtosecond laser microsurgery for large-scale in vivo neural degeneration and regeneration studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999) · SLAS Discovery · doi:10.1177/108705719900400206 · Cited by 6,847
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Systematic functional analysis of the Caenorhabditis elegans genome using RNAi
Kamath, R. S., Fraser, A. G., Dong, Y., Poulin, G., Durbin, R., Gotta, M., Kanapin, A., Le Bot, N., Moreno, S., Sohrmann, M., et al. (2003) · Nature · doi:10.1038/nature01278 · Cited by 3,616
Finding function in novel targets: C. elegans as a model organism
Kaletta, T., & Hengartner, M. O. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2031 · Cited by 1,093
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Genome-Wide RNAi of C. elegans Using the Hypersensitive rrf-3 Strain Reveals Novel Gene Functions
Simmer, F., Moorman, C., van der Linden, A. M., Kuijk, E., van den Berghe, P. V. E., Kamath, R. S., Fraser, A. G., Ahringer, J., & Plasterk, R. H. A. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000012 · Cited by 638
Functional regeneration after laser axotomy
Yanik, M. F., Cinar, H., Cinar, H. N., Chisholm, A. D., Jin, Y., & Ben-Yakar, A. (2004) · Nature · doi:10.1038/432822a · Cited by 598
Self-citationOxygen sensation and social feeding mediated by a C. elegans guanylate cyclase homologue
Gray, J. M., Karow, D. S., Lu, H., Chang, A. J., Chang, J. S., Ellis, R. E., Marletta, M. A., & Bargmann, C. I. (2004) · Nature · doi:10.1038/nature02714 · Cited by 590
Systematic analysis of genes required for synapse structure and function
Sieburth, D., Ch'ng, Q., Dybbs, M., Tavazoie, M., Kennedy, S., Wang, D., Dupuy, D., Rual, J.-F., Hill, D. E., Vidal, M., et al. (2005) · Nature · doi:10.1038/nature03809 · Cited by 392
Cited by
Caenorhabditis elegans: An Emerging Model in Biomedical and Environmental Toxicology
Leung, M. C. K., Williams, P. L., Benedetto, A., Au, C., Helmcke, K. J., Aschner, M., & Meyer, J. N. (2008) · Toxicological Sciences · doi:10.1093/toxsci/kfn121 · Cited by 1,027
On-chip manipulation of single microparticles, cells, and organisms using surface acoustic waves
Ding, X., Lin, S.-C. S., Kiraly, B., Yue, H., Li, S., Chiang, I.-K., Shi, J., Benkovic, S. J., & Huang, T. J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209288109 · Cited by 912
Rotational manipulation of single cells and organisms using acoustic waves
Ahmed, D., Ozcelik, A., Bojanala, N., Nama, N., Upadhyay, A., Chen, Y., Hanna-Rose, W., & Huang, T. J. (2016) · Nature Communications · doi:10.1038/ncomms11085 · Cited by 508
Automated on-chip rapid microscopy, phenotyping and sorting of C. elegans
Chung, K., Crane, M. M., & Lu, H. (2008) · Nature Methods · doi:10.1038/nmeth.1227 · Cited by 352
Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., et al. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02502-2 · Cited by 330
High-throughput in vivo vertebrate screening
Pardo-Martin, C., Chang, T.-Y., Koo, B. K., Gilleland, C. L., Wasserman, S. C., & Yanik, M. F. (2010) · Nature Methods · doi:10.1038/nmeth.1481 · Cited by 325
Self-citationIndustrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
High‐throughput screening and small animal models, where are we?
Giacomotto, J., & Ségalat, L. (2010) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2010.00725.x · Cited by 293
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Long-Term Imaging of Caenorhabditis elegans Using Nanoparticle-Mediated Immobilization
Kim, E., Sun, L., Gabel, C. V., & Fang-Yen, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053419 · Cited by 221
“elegans by compression [6], vacuum suction [7], temporary cooling [8], or carbon dioxide [9].”
Lens-free optical tomographic microscope with a large imaging volume on a chip
Isikman, S. O., Bishara, W., Mavandadi, S., Yu, F. W., Feng, S., Lau, R., & Ozcan, A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015638108 · Cited by 216
Lifespan-on-a-chip: microfluidic chambers for performing lifelong observation of C. elegans
Hulme, S. E., Shevkoplyas, S. S., McGuigan, A. P., Apfeld, J., Fontana, W., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b919265d · Cited by 213
Microfluidic very large scale integration (mVLSI) with integrated micromechanical valves
Araci, I. E., & Quake, S. R. (2012) · Lab on a Chip · doi:10.1039/c2lc40258k · Cited by 209
Femtosecond laser nanoaxotomy lab-on-a-chip for in vivo nerve regeneration studies
Guo, S. X., Bourgeois, F., Chokshi, T., Durr, N. J., Hilliard, M. A., Chronis, N., & Ben-Yakar, A. (2008) · Nature Methods · doi:10.1038/nmeth.1203 · Cited by 202
“elegans [69].”
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Artificial Dirt: Microfluidic Substrates for Nematode Neurobiology and Behavior
Lockery, S. R., Lawton, K. J., Doll, J. C., Faumont, S., Coulthard, S. M., Thiele, T. R., Chronis, N., McCormick, K. E., Goodman, M. B., & Pruitt, B. L. (2008) · Journal of Neurophysiology · doi:10.1152/jn.91327.2007 · Cited by 166
Metadata
- Authors
- Rohde, C. B., Zeng, F., Gonzalez-Rubio, R., Angel, M., & Yanik, M. F.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-08-28
- Volume
- 104
- Issue
- 35
- Pages
- 13891-13895
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1987631567
- Cited by
- 295
- References
- 14
- FWCI
- 18.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.